Characterization of a Novel Hafnium-Based X-ray Contrast Agent

被引:17
|
作者
Frenzel, Thomas [1 ]
Bauser, Marcus [1 ]
Berger, Markus [1 ]
Hilger, Christoph Stephan [1 ]
Hegele-Hartung, Christa [1 ]
Jost, Gregor [1 ]
Neis, Christian [2 ]
Hegetschweiler, Kaspar [2 ]
Riefke, Bjoern [1 ]
Suelzle, Detlev [1 ]
Pietsch, Hubertus [1 ]
机构
[1] Bayer Pharma AG, Drug Discovery, Muellerstr 178, D-13342 Berlin, Germany
[2] Univ Saarland, Inorgan Chem, Saarbrucken, Germany
关键词
CT imaging; hafnium; noniodine contrast agent; radiation dose; pharmacokinetics; toxicology; COMPUTED-TOMOGRAPHY; RADIATION-EXPOSURE; CT; GADOBUTROL; MEDIA;
D O I
10.1097/RLI.0000000000000291
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: Characterization of BAY-576, a new x-ray contrast agent which is not based on iodine, but rather on the heavy metal hafnium. Compared with iodine, hafnium provides better x-ray absorption in the energy range of computed tomography (CT) and allows images of comparable quality to be acquired at a significantly reduced radiation dose. Materials and Methods: A range of standard methods were used to explore the physicochemistry of BAY-576 as well as its tolerability in in vitro assays, its pharmacokinetics and toxicology in rats, and its performance in CT imaging in rabbits. Results: BAY-576 is an extraordinarily stable chelate with a metal content of 42% (wt/wt) and with excellent water solubility. Formulations of 300 mg Hf/mL exhibited viscosity (3.3-3.6 mPa) and osmolality (860-985 mOsm/kg) in the range of nonionic x-ray agents. No relevant effects on erythrocytes, the coagulation, or complement system or on a panel of 87 potential biological targets were observed. The compound did not bind to plasma proteins of a number of species investigated. After intravenous injection in rats, it was excreted fast and mainly via the kidneys. Its pharmacokinetics was comparable to known extracellular contrast agents. A dose of 6000 mg Hf/kg, approximately 10 to 20 times the expected diagnostic dose, was well tolerated by rats with only moderate adverse effects. Computed tomography imaging in rabbits bearing a tumor in the liver demonstrated excellent image quality when compared with iopromide at the same contrast agent dose in angiography during the arterial phase. At 70% of the radiation dose, BAY-576 provided a contrast-to-noise ratio of the tumor, which was equivalent to iopromide at 100% radiation dose. Conclusions: The profile of BAY-576 indicates its potential as the first compound in a new class of noniodine x-ray contrast agents, which can contribute to the reduction of the radiation burden in contrast-enhanced CT imaging.
引用
收藏
页码:776 / 785
页数:10
相关论文
共 50 条
  • [21] Gold nanoparticles: a new X-ray contrast agent - Reply
    Hainfeld, J. F.
    Slatkin, D. N.
    Focella, T. M.
    Smilowitz, H. M.
    BRITISH JOURNAL OF RADIOLOGY, 2007, 80 (949): : 65 - 65
  • [22] On citobarium (Merck), a new x-ray contrast agent.
    Bauermeister, W
    DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 1915, 41 : 768 - 769
  • [23] Determination of free iodine concentration in an X-ray contrast agent
    V. V. Kljubin
    K. A. Kljubina
    K. N. Makovetskaya
    Optics and Spectroscopy, 2016, 120 : 546 - 550
  • [24] Bismuth chelate as a contrast agent for X-ray computed tomography
    Fu, Ji-jun
    Guo, Jun-jie
    Qin, Ai-ping
    Yu, Xi-yong
    Zhang, Qiang
    Lei, Xue-ping
    Huang, Yu-gang
    Chen, Ming-yue
    Li, Jie-xia
    Zhang, Yu
    Liu, Jing-ping
    Dang, Yuan-ye
    Wu, Dan
    Zhao, Xiao-ya
    Lin, Zhong-xiao
    Lin, Yin-lei
    Li, Song-pei
    Zhang, Ling-yan
    JOURNAL OF NANOBIOTECHNOLOGY, 2020, 18 (01)
  • [25] Determination of free iodine concentration in an X-ray contrast agent
    Kljubin, V. V.
    Kljubina, K. A.
    Makovetskaya, K. N.
    OPTICS AND SPECTROSCOPY, 2016, 120 (04) : 546 - 550
  • [26] X-Ray Contrast Agent Technology. A Revolutionary History
    Fernandez Perez, Paloma
    BUSINESS HISTORY, 2022, 64 (03) : 628 - 628
  • [27] X-RAY STUDIES ON A HAFNIUM SULPHATE
    HANSSON, M
    LUNDGREN, G
    ACTA CHEMICA SCANDINAVICA, 1968, 22 (05): : 1683 - &
  • [28] The characterization of a phase contrast x-ray imaging prototype
    Donovan, Molly
    Zhang, Da
    Chen, Wei R.
    Liu, Hong
    COMPLEX DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IV, 2007, 6436
  • [29] Acoustic radiation pressure: A "phase contrast" agent for x-ray phase contrast imaging
    Bailat, CJ
    Hamilton, TJ
    Rose-Petruck, C
    Diebold, GJ
    APPLIED PHYSICS LETTERS, 2004, 85 (19) : 4517 - 4519
  • [30] X-ray phase contrast angiography using CO2 as contrast agent
    Lundstrom, Ulf
    Larsson, Daniel H.
    Takman, Per A. C.
    Scott, Lena
    Burvall, Anna
    Hertz, Hans M.
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313