Reliability of a high-intensity cycling capacity test

被引:15
|
作者
Saunders, Bryan [1 ]
Sale, Craig [1 ]
Harris, Roger C. [2 ]
Morris, John G. [3 ]
Sunderland, Caroline [1 ]
机构
[1] Nottingham Trent Univ, Sch Sci & Technol, Sport Hlth & Performance Enhancement SHAPE Res Gr, Nottingham NG11 8NS, England
[2] Junipa Ltd, Newmarket, Suffolk, England
[3] Univ Loughborough, Inst Youth Sport, Sch Sport Exercise & Hlth Sci, Loughborough, Leics, England
关键词
High-intensity cycling capacity; Reliability; CCT110%; STATISTICAL-METHODS; BETA-ALANINE; VARIABILITY;
D O I
10.1016/j.jsams.2012.07.004
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Objectives: To assess the reliability of the CCT110%, a high-intensity cycling capacity test performed to exhaustion. Design: 27 recreationally active participants (age 23 +/- 4 y; height 1.79 +/- 0.06 m; body mass 78.0 +/- 8.8 kg; Powermax 306 +/- 49W) performed the CCTi in on two occasions. Methods: Performance measures determined from the CCT110% were time to exhaustion (TTE) and total work done (TWD). Blood pH, lactate, bicarbonate and base excess were determined before exercise, immediately after exercise, and 5 min after exercise. Exercise capacity data were analysed using intraclass correlations (ICC), systematic bias ratio, ratio limits of agreement, coefficient of variation (CV) and t-tests. Blood variables were analysed using repeated measures ANOVA and Tukey tests for post hoc comparisons. Results: TTE (mean SD: 134 +/- 20 s and 135 +/- 20 s, P = 0.75) and TVVD (42.2 +/- 10.3 kJ and 42.2 +/- 9.8 kJ, P = 0.97) were not different between trials. The ICC between trials was r = 0.88 for TTE and r = 0.94 for TWD, with the CV being 4.43% for TTE and 4.94% for TWO. There were no between trial differences in blood markers at any time point except immediately post-exercise pH (7.246 +/- 0.041 vs. 7.269 +/- 0.064, P = 0.004). Conclusions: The CCTilo% is a reliable exercise protocol that can be used for nutritional interventions designed to affect intracellular and extracellular pH changes. Although blood pH was significantly different between trials immediately post-exercise, the absolute differences are much smaller than those expected to be seen using nutritional interventions intended to alter extracellular pH during exercise. 2012 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:286 / 289
页数:4
相关论文
共 50 条
  • [41] DIFFERENTIAL EFFECT OF METABOLIC ALKALOSIS AND HYPOXIA ON HIGH-INTENSITY CYCLING PERFORMANCE
    Flinn, Samantha
    Herbert, Kathryn
    Graham, Kenneth
    Siegler, Jason C.
    JOURNAL OF STRENGTH AND CONDITIONING RESEARCH, 2014, 28 (10) : 2852 - 2858
  • [42] Standardized Versus Customized High-Intensity Training: Effects on Cycling Performance
    Capostagno, Benoit
    Lambert, Michael I.
    Lamberts, Robert P.
    INTERNATIONAL JOURNAL OF SPORTS PHYSIOLOGY AND PERFORMANCE, 2014, 9 (02) : 292 - 301
  • [43] Pedalling rate affects endurance performance during high-intensity cycling
    Nielsen, JS
    Hansen, EA
    Sjogaard, G
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2004, 92 (1-2) : 114 - 120
  • [44] High-intensity acoustic test facility using hydraulics
    Lieberman, P
    JOURNAL OF THE IEST, 1999, 42 (01): : 46 - 50
  • [45] TEST OF QCD USING A HIGH-INTENSITY HADRON FACILITY
    ONEL, Y
    PENZO, A
    HELVETICA PHYSICA ACTA, 1986, 59 (6-7): : 1185 - 1185
  • [46] Combination of Sago and Soy-Protein Supplementation During Endurance Cycling Exercise and Subsequent High-Intensity Endurance Capacity
    Ghosh, Asok Kumar
    Rahaman, A. Abdul
    Singh, Rabindarjeet
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2010, 20 (03) : 216 - 223
  • [47] Comprehensive test stand for high-intensity cyclotron development
    ZHANG TianJue
    Science Bulletin, 2011, (03) : 238 - 244
  • [48] Comprehensive test stand for high-intensity cyclotron development
    Zhang TianJue
    Li ZhenGuo
    Chu ChengJie
    Xing JianSheng
    Guan FengPing
    Zhong JunQing
    Ji Bin
    Ge Tao
    Yin ZhiGuo
    Hou ShiGang
    Pan GaoFeng
    Yao HongJuan
    Lu YinLong
    Wang ZhenHui
    Wu LongCheng
    Lin Jun
    Jia XianLu
    Wei SuMin
    Wen LiPeng
    Wang Feng
    Xia Le
    Cai HongRu
    Xie HuaiDong
    Chen RongFan
    Zhang Yan
    Zhang SuPing
    Liu GengShou
    Zou Jian
    An ShiZhong
    Yang JianJun
    Bi YuanJie
    Yang Fang
    CHINESE SCIENCE BULLETIN, 2011, 56 (03): : 238 - 244
  • [49] Assessment of the reliability of high-intensity quadriceps femoris muscle fatigue
    Pincivero, DM
    Gear, WS
    Sterner, RL
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2001, 33 (02): : 334 - 338
  • [50] High-intensity Cycling Intervals Are Prescribed Accurately Using The 3-min All-out Exercise Test
    Dicks, Nathan D.
    Roloff, Zachery A.
    Krynski, Luke M.
    Pettitt, Robert W.
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2017, 49 (05): : 567 - 567