Determining the influence of Korean population variation on whole-body average SAR

被引:12
|
作者
Lee, Ae-Kyoung [1 ]
Choi, Hyung-Do [1 ]
机构
[1] Elect & Telecommun Res Inst, Radio Technol Res Dept, Taejon 305606, South Korea
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2012年 / 57卷 / 09期
关键词
ABSORPTION RATE; DIELECTRIC-PROPERTIES; FDTD CALCULATIONS; VOXEL MODELS; CHILD MODELS; 20; MHZ; GHZ; FREQUENCIES; TISSUE; PHANTOMS;
D O I
10.1088/0031-9155/57/9/2709
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Compliance of the ICNIRP reference and IEEE action levels with the basic restrictions on whole-body average (WBA) SAR was investigated based on age, physique, and posture under isolated and grounded conditions. First, Korean male models 1, 3, 5, 7, and 20 years of age with body sizes in the 50th percentile were developed and used as the test subjects: 1y(50th), 3y(50th), 5y(50th), 7y(50th), and 20y(50th). The effects of age-dependent dielectric properties due to the water content of the tissue on WBA SAR were analysed, and showed that the changes in WBA SAR are marginal. At the ages of 1, 5, and 20, thin models 1y(10th), 5y(10th), and 20y(10th) with body sizes in the 10th percentile for the horizontal plane were added in order to determine the influence of physical variations of the population. We considered standing postures with arms up and arms down. The WBA SAR for each human model was calculated when exposed to a vertically polarized plane wave in the frequency range of 10 MHz-3 GHz using the finite-difference time-domain method. The evaluated WBA SAR-based safety factor of each model is discussed for exposure to the ICNIRP reference and IEEE action levels. Finally, the lowest external electric field strength required to produce the basic restrictions on the WBA SAR, 0.08 W kg(-1), was obtained. The results showed that the ICNIRP public reference level is not conservative in the frequency range of 20-200 MHz for an arms-up posture, in the range of 40-200 MHz for an arms-down posture, and above 1 GHz for both postures. The IEEE action level is different from the ICNIRP reference level below 30 MHz, where most cases showed a safety factor of less than 50, which is the minimum value compliant with the basic restrictions for exposure to the general public.
引用
下载
收藏
页码:2709 / 2725
页数:17
相关论文
共 50 条
  • [21] Impact of whole-body MRI in a general population study
    Carsten Oliver Schmidt
    Elizabeth Sierocinski
    Katrin Hegenscheid
    Sebastian E. Baumeister
    Hans J. Grabe
    Henry Völzke
    European Journal of Epidemiology, 2016, 31 : 31 - 39
  • [22] Impact of whole-body MRI in a general population study
    Schmidt, Carsten Oliver
    Sierocinski, Elizabeth
    Hegenscheid, Katrin
    Baumeister, Sebastian E.
    Grabe, Hans J.
    Voelzke, Henry
    EUROPEAN JOURNAL OF EPIDEMIOLOGY, 2016, 31 (01) : 31 - 39
  • [23] Efficient Whole-Body SAR Assessments by Means of Surface Scan Measurements
    Colombi, Davide
    Thors, Bjorn
    Jonsson, B. Lars G.
    IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY, 2014, 56 (03) : 539 - 548
  • [24] Intercomparison of whole-body averaged SAR in European and Japanese voxel phantoms
    Dimbylow, Peter J.
    Hirata, Akimasa
    Nagaoka, Tomoaki
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (20): : 5883 - 5897
  • [25] CALCULATION OF WHOLE-BODY SAR FROM A 100 MHz DIPOLE ANTENNA
    Zhang, M.
    Alden, A.
    PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2011, 119 : 133 - 153
  • [26] VARIATION IN THICKNESS OF THE LARGE CRYOSECTIONS CUT FOR WHOLE-BODY AUTORADIOGRAPHY
    ITO, T
    BRILL, AB
    APPLIED RADIATION AND ISOTOPES, 1991, 42 (02) : 187 - &
  • [27] Radon influence in the estimation of background of whole-body counting
    Sugiura, N
    Kosako, T
    Eguchi, H
    IRPA9 - 1996 INTERNATIONAL CONGRESS ON RADIATION PROTECTION / NINTH INTERNATIONAL CONGRESS OF THE INTERNATIONAL RADIATION PROTECTION ASSOCIATION, PROCEEDINGS, VOL 2, 1996, : B415 - B417
  • [28] INFLUENCE OF WHOLE-BODY UV IRRADIATION ON ENDOCRINOLOGICAL PARAMETERS
    ALTMEYER, P
    HOLZMANN, H
    LUBE, U
    DERMATOLOGICA, 1983, 166 (04): : 186 - 191
  • [29] Influence of Whole-Body CT on Mortality for Circulatory Instability
    不详
    UNFALLCHIRURG, 2014, 117 (07): : 581 - 581
  • [30] Influence of whole-body vibration on the cognitive ability of reasoning
    Vasconcelos, Daniel Affonso
    Duarte, Maria Lucia Machado
    Donadon, Lazaro Valentim
    Neves, Jorge Alexandre Barbosa
    Nick, Herbert Camara
    COGNITION TECHNOLOGY & WORK, 2024, 26 (01) : 37 - 46