10-Year Follow-Up of Immediately Loaded Implants with TiUnite Porous Anodized Surface

被引:113
|
作者
Degidi, Marco [1 ]
Nardi, Diego [1 ]
Piattelli, Adriano [1 ]
机构
[1] Univ G dAnnunzio, Sch Dent, Chieti, Italy
关键词
immediate loading; implant surface; long term; TiUnite; SURVIVAL; SUCCESS;
D O I
10.1111/j.1708-8208.2012.00446.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Background: The immediate loading of implants with a porous anodized surface is a well-described technique. Few data are however available on the long-term outcomes. Purpose: The aim of this prospective study was to assess the 10-year performance of TiUnite implants supporting fixed prostheses placed with an immediate loading approach in both postextractive and healed sites. Materials and Methods: All patients received a fixed provisional restoration supported by immediately loaded parallel design, self-tapping implants with a porous anodized TiUnite surface, and an external-hexagonal connection. Both healed and postextractive cases were included. Success and survival rate for restorations and implants, changes in marginal peri-implant bone level, probing depth measurements, biological or technical complications, and any other adverse event were recorded at yearly follow-up up to 10 years after surgery. Results: A total of 210 implants fulfilled the inclusion criteria and were consecutively placed in 59 patients. Forty-seven (22.38%) implants were lost because of the recalled patient refused to attend the planned 10-year follow-up. Five over 210 (2.38%) implants were lost. At the final follow-up, the accumulated mean marginal bone loss and probing depth were, respectively, 1.93 mm (SD 0.40) and 2.54 mm (SD 0.44) for the implants placed in healed sites (n = 84); 1.98 mm (SD 0.37) and 2.63 mm (SD 0.39) for the implants placed in postextractive sites (n = 74). The restorations examined achieved a cumulative 65.26% success rate and 97.96% survival rate. The implants placed in healed and postextractive sites, respectively, achieved a 98.05% and a 96.52% cumulative survival rate. Conclusions: Positive results in terms of bone maintenance in the long-term perspective are to be expected using immediately loaded implants with a TiUnite porous anodized surface in both postextractive and healed sites when adequate levels of oral hygiene are kept.
引用
收藏
页码:828 / 838
页数:11
相关论文
共 50 条
  • [1] Immediately loaded titanium implants with a porous anodized surface with at least 36 months of follow-up
    Degidi, Marco
    Perrotti, Vittoria
    Piattelli, Adriano
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2006, 8 (04) : 169 - 177
  • [2] A 10-year follow-up study of contraceptive Norplant implants
    Du, MK
    Chow, LP
    Zheng, HM
    Chen, CHC
    INTERNATIONAL JOURNAL OF GYNECOLOGY & OBSTETRICS, 2000, 68 (03) : 249 - 256
  • [3] An Up to 12-Year Retrospective Follow-Up on Immediately Loaded, Surface-Modified Implants in the Edentulous Mandible
    Vandeweghe, Stefan
    Hawker, Peter
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2016, 18 (02) : 323 - 331
  • [4] A 5-year follow-up of 87 immediately loaded titanium implants.
    Degidi, M
    Patianna, D
    Orsini, G
    Piattelli, A
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A436 - A436
  • [5] 10-YEAR FOLLOW-UP
    MARKOWITZ, NR
    JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1979, 99 (02): : 177 - 177
  • [6] Custom Triflange Acetabular Implants: Average 10-Year Follow-Up
    Meding, John B.
    Meding, Lindsey K.
    JOURNAL OF ARTHROPLASTY, 2023, 38 (07): : S201 - S205
  • [7] AZOOR - A 10-year follow-up
    Smith-Hansen, Pia
    Gazieva, Lola
    Ilginis, Tomas
    ACTA OPHTHALMOLOGICA, 2016, 94 (05) : e379 - e380
  • [8] CHYLURIA - 10-YEAR FOLLOW-UP
    YU, HHY
    NGAN, H
    LEONG, CH
    BRITISH JOURNAL OF UROLOGY, 1978, 50 (02): : 126 - 133
  • [10] 10-year prospective cohort follow-up of mmediately restored XiVE implants
    Degidi, Marco
    Nardi, Diego
    Piattelli, Adriano
    CLINICAL ORAL IMPLANTS RESEARCH, 2016, 27 (06) : 694 - 700