The Protective Performance of Process Operators' Protective Clothing and Exposure Limits under Low Thermal Radiation Conditions

被引:1
|
作者
Heus, Ronald [1 ]
Kingma, Boris R. M. [2 ]
van Berlo, Birgit M. A. [3 ]
Mol, Douwe [2 ]
Daanen, Hein A. M. [3 ]
Kuklane, Kalev [1 ]
机构
[1] Team Fire Serv Sci, Netherlands Inst Publ Safety, Netherlands Acad Crisis Management & Fire Serv Sc, Zilverstr 91, NL-2718 RP Zoetermeer, Netherlands
[2] Netherlands Inst Appl Sci Res TNO, Human Performance Dept, Unit Def Safety & Secur, Kampweg 5, NL-3769 DE Soesterberg, Netherlands
[3] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Van der Boechorststr 9, NL-1081 BT Amsterdam, Netherlands
来源
BIOLOGY-BASEL | 2022年 / 11卷 / 08期
关键词
protective clothing; process operator; IR radiation; air gap; thermal protective performance; heat; skin temperature; exposure limit; petrochemical industry; AIR-GAP THICKNESS; BURN INJURIES; HEAT; INSULATION; SIMULATION; SKIN;
D O I
10.3390/biology11081222
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple Summary Process operators have an important monitoring role in the petrochemical industry. In the event of process disruptions and incidents, a process operator is often the first responder and takes measures to diminish the effects of an incident. Thus, a process operator can be exposed to dangerous circumstances, and therefore personal protective equipment has to be worn. In case of fire, the operator may be exposed to high heat radiation levels. Previous studies have established maximum acceptable heat radiation levels for long- (>15 min) and short-term exposures (<5 min), these being 1.0 kW/m(2) and 1.5 kW/m(2), respectively. These limits were based on manikin measurements and physiological models. The validation of the protection of operators' clothing in human trials is lacking. Therefore, twelve professional firefighters were exposed to three different heat radiation levels in process operators' clothing. The experiments showed that the majority of the operators can be exposed for 5 min to 1.5 kW/m(2), up to 3 min to 2.0 kW/m(2), while exposure to 2.5 kW/m(2) or above must be avoided. Due to a slower skin temperature rise, loose-fitting protective clothing was related to longer exposure times. We speculate that additional long-armed/legged (under)clothing may offer more protection and extend the exposure time to heat radiation. During the early stage of a fire, a process operator often acts as the first responder and may be exposed to high heat radiation levels. The present limit values of long- (>15 min) and short-term exposure (<5 min), 1.0 and 1.5 kW/m(2), respectively, have been set using physiological models and manikin measurements. Since human validation is essentially lacking, this study investigated whether operators' protective clothing offers sufficient protection during a short-term deployment. Twelve professional firefighters were exposed to three radiation levels (1.5, 2.0, and 2.5 kW/m(2)) when wearing certified protective clothing in front of a heat radiation panel in a climatic chamber (20 degrees C; 50% RH). The participants wore only briefs (male) or panties and a bra (female) and a T-shirt under the operators' clothing. Skin temperatures were continuously measured at the chest, belly, forearm, thigh, and knee. The test persons had to stop if any skin temperature reached 43 degrees C, at their own request, or when 5 min of exposure was reached. The experiments showed that people in operators' clothing can be safely exposed for 5 min to 1.5 kW/m(2), up to 3 min to 2.0 kW/m(2), and exposure to 2.5 kW/m(2) or above must be avoided unless the clothing can maintain an air gap.
引用
收藏
页数:23
相关论文
共 50 条
  • [41] Effect of aerogel on thermal protective performance of firefighter clothing
    Yoon, K. (keeyoon@dku.edu), 1600, Binary Information Press, 65 Weed Ave, Norwalk, CT 06850, United States (06):
  • [42] Thermal and cardiovascular strain imposed by motorcycle protective clothing under Australian summer conditions
    de Rome, Liz
    Taylor, Elizabeth A.
    Croft, Rodney J.
    Brown, Julie
    Fitzharris, Michael
    Taylor, Nigel A. S.
    ERGONOMICS, 2016, 59 (04) : 504 - 513
  • [43] Effects of air gap and compression on the dual performance of multilayer thermal protective clothing under low radiant heat
    Rui, Ke
    He, Jiazhen
    Xin, Meiyan
    Chen, Zhongwei
    Guan, Jinping
    JOURNAL OF INDUSTRIAL TEXTILES, 2024, 54
  • [44] A Comparison of Test Methods for Thermal Protective Performance of Fire-fighters' Protective Clothing
    Zhou, Liang
    Lu, Ye-Hu
    Li, Jun
    Li, Xiao-Hui
    TEXTILE BIOENGINEERING AND INFORMATICS SYMPOSIUM PROCEEDINGS, VOLS 1-3, 2011, : 1030 - 1034
  • [45] Protective performance of thermal protective clothing assemblies exposed to different radiant heat fluxes
    V. K. Kothari
    S. Chakraborty
    Fibers and Polymers, 2016, 17 : 809 - 814
  • [46] Thermal Protective Performance and Moisture Transmission of Firefighter Protective Clothing Based on Orthogonal Design
    Cui Zhiying
    Wan Yanmin
    Zhang Weiyuan
    JOURNAL OF INDUSTRIAL TEXTILES, 2010, 39 (04) : 347 - 356
  • [47] Protective Performance of Thermal Protective Clothing Assemblies Exposed to Different Radiant Heat Fluxes
    Kothari, V. K.
    Chakraborty, S.
    FIBERS AND POLYMERS, 2016, 17 (05) : 809 - 814
  • [48] Thermal Insulation of Protective Clothing Materials in Extreme Cold Conditions
    Zemzem, Mohamed
    Halle, Stephane
    Vinches, Ludwig
    SAFETY AND HEALTH AT WORK, 2023, 14 (01) : 107 - 117
  • [49] LIMITS OF EXERCISE PERFORMANCE IN MAN WEARING BREATHING APPARATUS AN PROTECTIVE CLOTHING
    KIRSCH, K
    VOGTKIRSCH, C
    WICKE, HJ
    ARBEITSMEDIZIN SOZIALMEDIZIN PRAVENTIVMEDIZIN, 1985, 20 (08): : 173 - 176
  • [50] The Thermal Protective Performance of Firefighters' Clothing: The Air Gap Between the Clothing and the Body
    Ghazy, Ahmed
    HEAT TRANSFER ENGINEERING, 2017, 38 (10) : 975 - 986