The Protective Performance of Process Operators' Protective Clothing and Exposure Limits under Low Thermal Radiation Conditions

被引:1
|
作者
Heus, Ronald [1 ]
Kingma, Boris R. M. [2 ]
van Berlo, Birgit M. A. [3 ]
Mol, Douwe [2 ]
Daanen, Hein A. M. [3 ]
Kuklane, Kalev [1 ]
机构
[1] Team Fire Serv Sci, Netherlands Inst Publ Safety, Netherlands Acad Crisis Management & Fire Serv Sc, Zilverstr 91, NL-2718 RP Zoetermeer, Netherlands
[2] Netherlands Inst Appl Sci Res TNO, Human Performance Dept, Unit Def Safety & Secur, Kampweg 5, NL-3769 DE Soesterberg, Netherlands
[3] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Van der Boechorststr 9, NL-1081 BT Amsterdam, Netherlands
来源
BIOLOGY-BASEL | 2022年 / 11卷 / 08期
关键词
protective clothing; process operator; IR radiation; air gap; thermal protective performance; heat; skin temperature; exposure limit; petrochemical industry; AIR-GAP THICKNESS; BURN INJURIES; HEAT; INSULATION; SIMULATION; SKIN;
D O I
10.3390/biology11081222
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Simple Summary Process operators have an important monitoring role in the petrochemical industry. In the event of process disruptions and incidents, a process operator is often the first responder and takes measures to diminish the effects of an incident. Thus, a process operator can be exposed to dangerous circumstances, and therefore personal protective equipment has to be worn. In case of fire, the operator may be exposed to high heat radiation levels. Previous studies have established maximum acceptable heat radiation levels for long- (>15 min) and short-term exposures (<5 min), these being 1.0 kW/m(2) and 1.5 kW/m(2), respectively. These limits were based on manikin measurements and physiological models. The validation of the protection of operators' clothing in human trials is lacking. Therefore, twelve professional firefighters were exposed to three different heat radiation levels in process operators' clothing. The experiments showed that the majority of the operators can be exposed for 5 min to 1.5 kW/m(2), up to 3 min to 2.0 kW/m(2), while exposure to 2.5 kW/m(2) or above must be avoided. Due to a slower skin temperature rise, loose-fitting protective clothing was related to longer exposure times. We speculate that additional long-armed/legged (under)clothing may offer more protection and extend the exposure time to heat radiation. During the early stage of a fire, a process operator often acts as the first responder and may be exposed to high heat radiation levels. The present limit values of long- (>15 min) and short-term exposure (<5 min), 1.0 and 1.5 kW/m(2), respectively, have been set using physiological models and manikin measurements. Since human validation is essentially lacking, this study investigated whether operators' protective clothing offers sufficient protection during a short-term deployment. Twelve professional firefighters were exposed to three radiation levels (1.5, 2.0, and 2.5 kW/m(2)) when wearing certified protective clothing in front of a heat radiation panel in a climatic chamber (20 degrees C; 50% RH). The participants wore only briefs (male) or panties and a bra (female) and a T-shirt under the operators' clothing. Skin temperatures were continuously measured at the chest, belly, forearm, thigh, and knee. The test persons had to stop if any skin temperature reached 43 degrees C, at their own request, or when 5 min of exposure was reached. The experiments showed that people in operators' clothing can be safely exposed for 5 min to 1.5 kW/m(2), up to 3 min to 2.0 kW/m(2), and exposure to 2.5 kW/m(2) or above must be avoided unless the clothing can maintain an air gap.
引用
收藏
页数:23
相关论文
共 50 条
  • [1] THERMAL PROTECTIVE PERFORMANCE OF FIREFIGHTERS' CLOTHING UNDER LOW-INTENSITY RADIATION HEAT EXPOSURE
    He, Hualing
    Yu, Zhicai
    Zhang, Chunbo
    Li, Minhua
    AUTEX RESEARCH JOURNAL, 2021, 21 (03) : 234 - 241
  • [2] Analysis of evaluation method of thermal protective performance of firefighter protective clothing exposure to low level radiation
    Deng, Meng
    Wang, Yunyi
    Fangzhi Xuebao/Journal of Textile Research, 2017, 38 (12): : 162 - 168
  • [4] Thermal performance of protective clothing (firefighter) under extreme ambient conditions
    Gohar, Emadeldin sayed
    Mazari, Adnan ahmed
    INDUSTRIA TEXTILA, 2023, 74 (05): : 542 - 546
  • [5] The effects of moisture on the thermal protective performance of firefighter protective clothing under medium intensity radiant exposure
    Zhang, Hui
    Song, Guowen
    Ren, Haitao
    Cao, Juan
    TEXTILE RESEARCH JOURNAL, 2018, 88 (08) : 847 - 862
  • [6] Thermal Protective Performance of Silica Aerogel Felt Bedded Firefighters' Protective Clothing under Fire Conditions
    Huang, Dongmei
    Guo, Chenning
    MATERIALS SCIENCE-MEDZIAGOTYRA, 2017, 23 (04): : 335 - 341
  • [7] Studies on the effect of process parameters on the thermal protective performance of multilayer thermal protective clothing
    Maurya, Sudhanshu
    Rathour, Rochak
    Mishra, Pranav
    Mishra, Divya
    Das, Apurba
    Ramasamy, Alagirusamy
    JOURNAL OF THE TEXTILE INSTITUTE, 2024, 115 (09) : 1574 - 1585
  • [8] Studies on the effect of process parameters on the thermal protective performance of multilayer thermal protective clothing
    Maurya, Sudhanshu
    Rathour, Rochak
    Mishra, Pranav
    Mishra, Divya
    Das, Apurba
    Ramasamy, Alagirusamy
    JOURNAL OF THE TEXTILE INSTITUTE, 2023,
  • [9] INFLUENCE OF PROTECTIVE CLOTHING ON HUMAN STRESS IN WORK UNDER EXPOSURE TO THERMAL-RADIATION
    HERTTING, R
    HETTINGER, T
    EISSING, G
    ARBEITSMEDIZIN SOZIALMEDIZIN PRAVENTIVMEDIZIN, 1984, 19 (01): : 9 - 14
  • [10] Thermal protective performance of protective clothing used for low radiant heat protection
    Song, Guowen
    Paskaluk, Stephen
    Sati, Rohit
    Crown, Elizabeth M.
    Dale, J. Doug
    Ackerman, Mark
    TEXTILE RESEARCH JOURNAL, 2011, 81 (03) : 311 - 323