Delivery of formoterol from a novel multi-dose inhaler Airmax™

被引:11
|
作者
Zeng, XM
Jones, S
O'Leary, D
Phelan, M
Colledge, J
机构
[1] IVAX Pharmaceut UK Ltd, Pulm Res & Dev, London E16 2QJ, England
[2] IVAX Ireland, Waterford, Ireland
[3] Yamanouchi Europe BV, Pharmaceut R&D, Leiderdorp, Netherlands
关键词
Airmax (TM); active metering; cyclone separator; dry powder inhalers; formoterol;
D O I
10.1053/rmed.2002.1361
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Using a proprietary technology known as the X-ACT(TM) system-Active-metering, Cyclone-separator Technology, a novel multi-dose inhaler (Airmax(TM)) was developed to provide accurate and consistent dosing and a high-fine particle fraction of the drug. Formoterol, present as a blend with lactose monohydrate was delivered from Airmax(TM) to obtain a nominal formoterol dose of 6 or 12 mug. The devices were tested using a five-stage liquid impinger and a unit dose sampling apparatus, operated under conditions specified in European Pharmacopoeia (2000). Fine-particle dose (FPD) was defined as the dose of the aerosolized drug particles with an aerodynamic diameter <5 mum and fine particle fraction (FPF) was the ratio of FPD to the total recovered dose. Dose per actuation was found to be 97.0+/-11.5% label claim (LC)or 5.8+/-0.7 mug (n=140), and 100+/-9.4% LC or 12+/-1.1 mug (n=440), for the 6 and 12 mug strengths, respectively. The mass median aerodynamic diameter was 2.4+/-0.1 mum (n=14), the geometric standard deviation 2.1+/-0.1 (n=14), and FPF 44.4+/-2.4% (n=14) for both strengths. Thus, the combination of active metering and cyclone separator produces highly consistent doses of formoterol that have a large respirable fraction. (C) 2002 Elsevier Science Ltd.
引用
收藏
页码:397 / 403
页数:7
相关论文
共 50 条
  • [31] An Updated Model For Prediction Of Asthma Exacerbations Using Albuterol Electronic Multi-dose Dry Powder Inhaler
    Merchant, Rajan
    Safioti, Guilherme
    Granovsky, Lena
    Reich, Michael
    Li, Thomas
    Hill, Tanisha
    Pleasants, Roy
    Mosnaim, Giselle
    Depietro, Michael
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2020, 145 (02) : AB211 - AB211
  • [32] Aerosol delivery from an active emission multi-single dose dry powder inhaler
    Concessio, NM
    JagerWaldau, R
    Hickey, AJ
    PARTICULATE SCIENCE AND TECHNOLOGY, 1997, 15 (01) : 51 - 63
  • [34] Dynamically optimizing the administration of vaccines from multi-dose vials
    Mofrad, Maryam H.
    Maillart, Lisa M.
    Norman, Bryan A.
    Rajgopal, Jayant
    IIE TRANSACTIONS, 2014, 46 (07) : 623 - 635
  • [35] Asthma: Multi-Dose as good as Single-Dose
    不详
    ALLERGO JOURNAL, 2008, 17 (03) : 254 - 254
  • [36] DRUG CONTAMINATION OF MULTI-DOSE VIALS
    SMITH, RM
    YOUNG, JA
    MANHEIM, A
    ANESTHESIOLOGY, 1967, 28 (01) : 268 - &
  • [37] Comparative bronchodilatory effects of formoterol dry powder inhaler (DPI) versus the combination of formoterol and budesonide pressurized metered-dose inhaler (pMDI)
    Mezzanotte, W. S.
    Miller, C. J.
    Senn, S.
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2007, 119 (01) : S248 - S248
  • [38] MODIFYING DELIVERY TECHNIQUE OF FENOTEROL FROM A METERED DOSE INHALER
    THOMAS, P
    WILLIAMS, T
    REILLY, PA
    BRADLEY, D
    ANNALS OF ALLERGY, 1984, 52 (04): : 279 - 281
  • [39] DELIVERY OF PROPELLANT SOLUBLE DRUG FROM A METERED DOSE INHALER
    ASHWORTH, HL
    WILSON, CG
    SIMS, EE
    WOTTON, PK
    HARDY, JG
    THORAX, 1991, 46 (04) : 245 - 247
  • [40] Efficacy and safety of fluticasone and formoterol in a single pressurized metered dose inhaler
    Bodzenta-Lukaszyk, Anna
    Pulka, Grazyna
    Dymek, Andrzej
    Bumbacea, Dragos
    McIver, Tammy
    Schwab, Birgit
    Mansikka, Heikki
    RESPIRATORY MEDICINE, 2011, 105 (05) : 674 - 682