Improved test time evaluation in an expansion tube

被引:15
|
作者
James, Christopher M. [1 ]
Cullen, Timothy G. [1 ]
Wei, Han [1 ,2 ]
Lewis, Steven W. [1 ]
Gu, Sangdi [1 ]
Morgan, Richard G. [1 ]
McIntyre, Timothy J. [3 ]
机构
[1] Univ Queensland, Ctr Hyperson, Sch Mech & Min Engn, St Lucia, Qld 4072, Australia
[2] Natl Univ Singapore, Dept Mech Engn, Singapore 117575, Singapore
[3] Univ Queensland, Ctr Hyperson, Sch Math & Phys, St Lucia, Qld 4072, Australia
基金
澳大利亚研究理事会;
关键词
FREE-PISTON DRIVER; BLUNT-BODY; FLOW; PRESSURE; REENTRY; ENTRY; SPHERES; AIR;
D O I
10.1007/s00348-018-2540-1
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Traditionally, expansion tube test times have been experimentally evaluated using test section mounted impact pressure probes. This paper proposes two new methods which can be performed using a high-speed camera and a simple circular cylinder test model. The first is the use of a narrow bandpass optical filter to allow time-resolved radiative emission from an important species to be captured, and the second is using edge detection to track how the model shock standoff changes with time. Experimental results are presented for two test conditions using an air test gas and an optical filter aimed at capturing emission from the 777 nm atomic oxygen triplet. It is found that the oxygen emission is the most reliable experimental method, because it is shown to exhibit significant changes at the end of the test time. It is also proposed that, because the camera footage is spatially resolved, the radiative emission method can be used to examine the 'effective' test time in multiple regions of the flow. For one of the test conditions, it is found that the effective test time away from the stagnation region for the cylindrical test model is at most 45% of the total test time. For the other test condition, it is found that the effective test time of a 54 degrees wedge test model is at most a third of the total test time.
引用
收藏
页数:21
相关论文
共 50 条
  • [41] PROPOSITION OF AN IMPROVED TEST FOR THE EVALUATION OF SENSORIC DIFFERENCES
    SEEMANN, G
    ARCHIV FUR GEFLUGELKUNDE, 1981, 45 (06): : 248 - 251
  • [42] PRESERVATIVE EVALUATION - DESIGNING AN IMPROVED TEST SYSTEM
    COOKE, PK
    GANDHI, UR
    LASHEN, ES
    LEASURE, EL
    JOURNAL OF COATINGS TECHNOLOGY, 1991, 63 (796): : 33 - 38
  • [43] An improved test control architecture and test control expansion for core-based system chips
    Waayers, T
    INTERNATIONAL TEST CONFERENCE 2003, PROCEEDINGS, 2003, : 1145 - 1154
  • [44] MODIFIED EXPANSION TUBE
    SPURK, JH
    GION, EJ
    STUREK, WB
    AIAA JOURNAL, 1969, 7 (02) : 345 - &
  • [45] INFLUENCE OF TURBULENT BOUNDARY LAYER ON SHOCK TUBE TEST TIME
    JEANMARI.P
    BROCHER, EF
    AIAA JOURNAL, 1965, 3 (05) : 960 - &
  • [46] Evaluation of Direct Tube Coagulase Test in Diagnosing Staphylococcal Bacteremia
    Thirunavukkarasu, Sandeep
    Rathish, K. C.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2014, 8 (05) : DC19 - DC21
  • [47] Evaluation of Hydroform ability of TRIP Steel Tube by Flaring Test
    Zhang, Zi-Cheng
    Manabe, Ken-ichi
    Zhu, Fu-Xian
    Mirzai, Mohammad Ali
    Li, Tong-Hong
    JOURNAL OF THE CHINESE SOCIETY OF MECHANICAL ENGINEERS, 2010, 31 (01): : 39 - 46
  • [48] Damage evaluation in tube spinnability test with ductile fracture criteria
    Ma, Hao
    Xu, Wenchen
    Jin, Bo Cheng
    Shan, Debin
    Nutt, Steven R.
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2015, 100 : 99 - 111
  • [49] COMPARATIVE EVALUATION OF SLIDE HEMAGGLUTINATION AND TUBE HEMAGGLUTINATION TEST IN TOXOPLASMOSIS
    MAHAJAN, RC
    JOSHI, RM
    INDIAN JOURNAL OF MEDICAL RESEARCH, 1979, 69 (FEB) : 247 - 250
  • [50] Test Experiment on a New Type of Packer Rubber Tube with Ultrahigh Pressure and Expansion Cutter
    Chen, Yizhe
    2ND INTERNATIONAL CONFERENCE ON SIMULATION AND MODELING METHODOLOGIES, TECHNOLOGIES AND APPLICATIONS (SMTA 2015), 2015, : 704 - 706