Cost-effective Air Conditioning Control Considering Comfort Level and User Location

被引:0
|
作者
Godo, Sachio [1 ]
Matsui, Kanae [2 ]
Nishi, Hiroaki [3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Fujisawa, Kanagawa, Japan
[2] Keio Univ, Keio Adv Res Ctr, Fujisawa, Kanagawa, Japan
[3] Keio Univ, Fac Sci & Technol, Dept Syst Design, Fujisawa, Kanagawa, Japan
关键词
Air conditioning control; Cost effectiveness; Pressure sensor; Comfort;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heating, ventilation, and air conditioning (HVAC) are important factors for a building energy management system (BEMS). Efficient control of the air conditioning (AC) is required to maintain both energy efficiency and human comfort. However, AC control systems are expensive to install in buildings. In this study, a cost-effective AC control system intended for a library is proposed; it is also applicable to other facilities such as offices and meeting spaces. This system uses seating sensors for maintaining both energy efficiency and human comfort. Conventional AC control systems generally use expensive motion sensors or vision sensors as well as temperature and humidity sensors to acquire information on both the location and the comfort of users and to provide location-based control to users. In order to reduce sensor-based cost, the proposed system uses low-cost pressure sensors and maintains both energy efficiency and the comfort level. For detecting seat occupancy and locations, low-cost pressure sensors and low-power communication nodes are attached to chairs and they transmit seating data to the database of a server. A programmable logic controller is used to control the proposed AC system according to the information stored in the database. The system is evaluated using a 10-day experiment conducted at a library in Kurihara City in Miyagi prefecture of Japan. The results of energy efficiency evaluation in this experiment show that the proposed system can reduce electricity consumption by 18.3%. Through measurement of the predicted mean vote values of users of the library, the proposed system is found to be capable of maintaining user comfort.
引用
收藏
页码:5344 / 5349
页数:6
相关论文
共 50 条
  • [31] NIR for cost-effective production control
    Warner, J
    FOOD AUSTRALIA, 2005, 57 (07): : 277 - 277
  • [32] COST-EFFECTIVE INSTRUMENTATION CONTROL IN 1988
    LEACH, T
    ELECTRONICS & WIRELESS WORLD, 1988, 94 (1634): : 1232 - 1233
  • [33] Determining a cost-effective customer service level
    Jeffery, Mariah M.
    Butler, Renee J.
    Malone, Linda C.
    SUPPLY CHAIN MANAGEMENT-AN INTERNATIONAL JOURNAL, 2008, 13 (03) : 225 - 232
  • [35] Cost-Effective Control of Ground-Level Ozone Pollution in and around Beijing
    Xie Xuxuan
    Zhang Shiqiu
    Xu Jianhua
    Wu Dan
    Zhu Tong
    CHINESE JOURNAL OF POPULATION RESOURCES AND ENVIRONMENT, 2012, 10 (02) : 101 - 109
  • [36] CONDITIONING, CENTRIFUGE KEY TO COST-EFFECTIVE PIT WATER CLEANUP
    不详
    OIL & GAS JOURNAL, 1987, 85 (06) : 36 - 37
  • [37] Air conditioner consumption optimization in an office building considering user comfort
    Khorram, Mahsa
    Faria, Pedro
    Abrishambaf, Omid
    Vale, Zita
    ENERGY REPORTS, 2020, 6 : 120 - 126
  • [38] An Optimization Control Method of IEH Considering User Thermal Comfort
    Zheng, Huankun
    Yu, Kaidi
    ENERGIES, 2024, 17 (04)
  • [39] POTENTIAL FOR COST EFFECTIVE MAGNETOCALORIC AIR CONDITIONING SYSTEMS
    Russek, S. L.
    Zimm, C.
    1ST INTERNATIONAL CONFERENCE ON MAGNETIC REFRIGERATION AT ROOM TEMPERATURE, 2005, : 59 - 68
  • [40] Potential for cost effective magnetocaloric air conditioning systems
    Russek, Steven L.
    Zimm, Carl B.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2006, 29 (08): : 1366 - 1373