Cost-effective Air Conditioning Control Considering Comfort Level and User Location

被引:0
|
作者
Godo, Sachio [1 ]
Matsui, Kanae [2 ]
Nishi, Hiroaki [3 ]
机构
[1] Keio Univ, Grad Sch Sci & Technol, Fujisawa, Kanagawa, Japan
[2] Keio Univ, Keio Adv Res Ctr, Fujisawa, Kanagawa, Japan
[3] Keio Univ, Fac Sci & Technol, Dept Syst Design, Fujisawa, Kanagawa, Japan
关键词
Air conditioning control; Cost effectiveness; Pressure sensor; Comfort;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heating, ventilation, and air conditioning (HVAC) are important factors for a building energy management system (BEMS). Efficient control of the air conditioning (AC) is required to maintain both energy efficiency and human comfort. However, AC control systems are expensive to install in buildings. In this study, a cost-effective AC control system intended for a library is proposed; it is also applicable to other facilities such as offices and meeting spaces. This system uses seating sensors for maintaining both energy efficiency and human comfort. Conventional AC control systems generally use expensive motion sensors or vision sensors as well as temperature and humidity sensors to acquire information on both the location and the comfort of users and to provide location-based control to users. In order to reduce sensor-based cost, the proposed system uses low-cost pressure sensors and maintains both energy efficiency and the comfort level. For detecting seat occupancy and locations, low-cost pressure sensors and low-power communication nodes are attached to chairs and they transmit seating data to the database of a server. A programmable logic controller is used to control the proposed AC system according to the information stored in the database. The system is evaluated using a 10-day experiment conducted at a library in Kurihara City in Miyagi prefecture of Japan. The results of energy efficiency evaluation in this experiment show that the proposed system can reduce electricity consumption by 18.3%. Through measurement of the predicted mean vote values of users of the library, the proposed system is found to be capable of maintaining user comfort.
引用
收藏
页码:5344 / 5349
页数:6
相关论文
共 50 条
  • [1] Air Conditioning Control Using Self-Powered Sensor Considering Comfort Level and Occupant Location
    Godo, Sachio
    Haase, Jan
    Nishi, Hiroaki
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 2497 - 2502
  • [2] COST-EFFECTIVE TECHNOLOGIES TO CONTROL INDOOR AIR QUALITY AND COMFORT IN ENERGY EFFICIENT BUILDING RETROFITTING
    Revel, Gian Marco
    Arnesano, Marco
    Pietroni, Filippo
    Frick, Juergen
    Reichert, Manuela
    Schmitt, Katrin
    Huber, Jochen
    Ebermann, Martin
    Battista, Umberto
    Alessi, Franck
    ENVIRONMENTAL ENGINEERING AND MANAGEMENT JOURNAL, 2015, 14 (07): : 1487 - 1494
  • [3] Cost-effective conditioning and dewatering
    Metcalf and Eddy Inc., Wakefield, MA
    不详
    Water Environ Technol, 2006, 11 (64-69):
  • [4] AIR-CONDITIONING SYSTEM RELIES ON WATERWHEEL TO MAKE IT COST-EFFECTIVE
    不详
    BUILDING SYSTEMS DESIGN, 1978, 75 (03): : 38 - 42
  • [5] Quick and cost-effective cable location
    Vector (Electrical Engineering), 1998,
  • [6] Cost-effective compressor control to reduce oversupply of compressed air
    Vermeulen, J.
    Cilliers, C.
    Marais, J. H.
    2017 INTERNATIONAL CONFERENCE ON THE INDUSTRIAL AND COMMERCIAL USE OF ENERGY (ICUE), 2017,
  • [7] Temperature control method of a car air conditioning system considering passenger's comfort
    Watanuki, K
    Murata, T
    Ohtaki, H
    COMPUTER APPLICATIONS IN INDUSTRY AND ENGINEERING, 2000, : 302 - 306
  • [8] Robotic wheelchair control considering user comfort
    Solea, Razvan
    Nunes, Urbano
    ICINCO 2008: PROCEEDINGS OF THE FIFTH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL RA-1: ROBOTICS AND AUTOMATION, VOL 1, 2008, : 37 - 44
  • [10] A COST-EFFECTIVE INDUSTRIAL-LOCATION POLICY
    TOMLINSON, R
    SOUTH AFRICAN JOURNAL OF ECONOMICS, 1990, 58 (02) : 157 - 172