Spectrophotometric determination of fluoride in drinking water using aluminium complexes of triphenylmethane dyes

被引:18
|
作者
Barghouthi, Zaher [1 ]
Amereih, Sameer [2 ]
机构
[1] Karl Franzens Univ Graz, Inst Chem, A-8010 Graz, Austria
[2] Palestine Tech Univ Kadoori, Tullkarm, Israel
关键词
Fluoride analysis; spectrophotometric method; drinking water; aluminium triphenylmethane dye complexes; chrome azurol B; malachite green; CHROME AZUROL-S; TRACE AMOUNTS; GROUNDWATER; ZIRCONIUM; CONTAMINATION; PHOSPHATE; REMOVAL; ION;
D O I
10.4314/wsa.v38i4.9
中图分类号
TV21 [水资源调查与水利规划];
学科分类号
081501 ;
摘要
A sensitive spectrophotometric determination of fluoride in drinking water has been developed using aluminium complexes of triphenylmethane dyes (chrome azurol B and malachite green) as spectrophotometric reagents. The method allowed a reliable determination of fluoride in the range of 0.5-4.0 mg.l(-1) for chrome azurol B and 0.0-2.0 mg.l(-1) for malachite green. The molar absorptivity for the complexes of chrome azurol B at 582 nm and malachite green at 622 nm is 1.44 x 10(4) and 2.56 x 10(4) l.mol(-1).cm(-1), respectively. The sensitivity, detection limit, quantitation limit, and percentage recovery for 1.5 mg.l(-1) fluoride for the method using chrome azurol B were found to be 0.125 +/- 0.003 mu g.ml(-1), 0.2 mg.l(-1), 0.5 mg.l(-1), and 97.1 +/- 4.2, respectively, and for malachite green were 0.143 +/- 0.002 mu g.ml(-1), 0.1 mg.l(-1), 0.3 mg.l(-1), and 97.9 +/- 4.1, respectively.
引用
收藏
页码:543 / 548
页数:6
相关论文
共 50 条
  • [41] COMBINED ALUMINIUM SULFATE/HYDROXIDE PROCESS FOR FLUORIDE REMOVAL FROM DRINKING WATER
    Zewge, Feleke
    BULLETIN OF THE CHEMICAL SOCIETY OF ETHIOPIA, 2016, 30 (03) : 391 - 401
  • [42] Spectrophotometric determination of hydrogen peroxide in water by oxidative decolorization of azo dyes using Fenton system
    Wang, Daiyao
    Qiu, Shiyi
    Wang, Mengyun
    Pan, Siwen
    Ma, Hongfang
    Zou, Jing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 221
  • [43] The impact of aluminum, fluoride, and aluminum–fluoride complexes in drinking water on chronic kidney disease
    Hewa M. S. Wasana
    Gamage D. R. K. Perera
    Panduka S. De Gunawardena
    Jayasundera Bandara
    Environmental Science and Pollution Research, 2015, 22 : 11001 - 11009
  • [44] DETERMINATION OF AN ACCEPTABLE NATURAL FLUORIDE CONCENTRATION IN DRINKING-WATER
    VANWYK, PJ
    SNYMAN, WD
    LOUW, AJ
    VANWYK, CW
    JOURNAL OF DENTAL RESEARCH, 1984, 63 (04) : 596 - 596
  • [45] Field determination of fluoride in drinking water using a polymeric aluminium complex of 5-(2-carboxyphenylazo)-8-hydroxyquinoline impregnated paper
    Barghouthi, Zaher
    Amereih, Sameer
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2013, 93 (05) : 565 - 577
  • [46] Sensitive Spectrophotometric Method for Determination of Trace Aluminium in Water Samples by Morin
    Yuan Dong
    Fu Dayou
    FRONTIERS OF GREEN BUILDING, MATERIALS AND CIVIL ENGINEERING, PTS 1-8, 2011, 71-78 : 2173 - 2176
  • [47] Spectrophotometric determination of polyacrylamide in aqueous solutions using cationic dyes
    Chmilenko, FA
    Korobova, IV
    Nazarenko, SV
    JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 59 (02) : 124 - 128
  • [48] Spectrophotometric Determination of Polyacrylamide in Aqueous Solutions Using Cationic Dyes
    F. A. Chmilenko
    I. V. Korobova
    S. V. Nazarenko
    Journal of Analytical Chemistry, 2004, 59 : 124 - 128
  • [49] EXTRACTIVE SPECTROPHOTOMETRIC DETERMINATION OF DIURETICS USING BASIC-DYES
    PRASAD, TNV
    SASTRY, BS
    RAO, EV
    SASTRY, CSP
    PHARMAZIE, 1987, 42 (02): : 135 - 136
  • [50] Kinetic Spectrophotometric Method for 4-nitrophenol Determination in Drinking Water
    Miletic, A. S.
    Pecev-Marinkovic, E. T.
    Grahovac, Z. M.
    Pavlovic, A. N.
    Tosic, S. B.
    Misic, I. D. Rasic
    JOURNAL OF ANALYTICAL CHEMISTRY, 2019, 74 (06) : 521 - 527