Pediatric transthoracic defibrillation: biphasic versus monophasic waveforms in an experimental model

被引:51
|
作者
Clark, CB [1 ]
Zhang, Y [1 ]
Davies, LR [1 ]
Karlsson, G [1 ]
Kerber, RE [1 ]
机构
[1] Univ Iowa, Ctr Cardiovasc, Iowa City, IA 52242 USA
关键词
defibrillation; waveforms; pediatrics; infants; pigs;
D O I
10.1016/S0300-9572(01)00398-7
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objectives: The purpose of this study was to determine and compare the efficacy of biphasic and monophasic waveforms in a porcine model of pediatric defibrillation. Background: The efficacy and safety of biphasic waveforms in children has not been established. Methods: We initially studied 27 piglets: 12 weighed 3-6 kg ('infants'), and 15 weighed 7-12 kg ('children'). Ventricular fibrillation (VF) was induced by rapid right ventricular pacing and maintained for 15 s. Transthoracic shocks of 7-100 J energy were given using monophasic (5 ms truncated exponential) and biphasic (5 ms positive, 5 ms negative pulse, truncated exponential) waveforms. A second study of four 'infant' and four 'child' piglets utilized the same protocol but with a 10 ms instead of 5 ms monophasic truncated exponential shock waveform compared with the 10 ms biphasic waveform. Results: For both biphasic and monophasic waveforms, shock success rate (termination of VF) rose steadily as energy was increased. In the first study in the 'infant' 3-6 kg group, the 10 ms biphasic waveforms were superior to 5 ms monophasic waveforms at 10, 20, and 30 J energies, and in the 'child' 7-12 kg group at 20 and 30 J energies (P < 0.05). High success rates ( > 80%) were achieved by 20 J (4 J/kg) biphasic waveform shocks in the 'infant' piglets and 30 J (3 J/kg) biphasic waveform shocks in the 'child' piglets. In the second study using a 10 ms monophasic waveform, we found similar results. Pulseless electrical activity occurred in two animals following biphasic shocks and in two animals following monophasic shocks. Conclusions: Biphasic waveforms proved superior to monophasic waveforms in both infant and child models. High success rates were achieved with low-energy biphasic shocks. Biphasic waveform defibrillation is a promising advance in pediatric resuscitation. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:159 / 163
页数:5
相关论文
共 50 条
  • [31] Modelling transthoracic defibrillation waveforms
    Krasteva, V
    Cansell, A
    Daskalov, I
    JOURNAL OF MEDICAL ENGINEERING & TECHNOLOGY, 2000, 24 (02) : 63 - 67
  • [32] Modelling transthoracic defibrillation waveforms
    Krasteva, V.
    Cansell, A.
    Daskalov, I.
    Journal of Medical Engineering and Technology, 2000, 24 (02): : 63 - 67
  • [33] Arrhythmogenicity of monophasic and biphasic PFA waveforms in a porcine model
    Kumru, Hanife Tugba
    Mattison, Lars
    Tarakji, Khaldoun G.
    Verma, Atul
    Sigg, Daniel C.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2024,
  • [34] Monophasic versus biphasic transthoracic countershock after prolonged ventricular fibrillation in a swine model
    Niemann, JT
    Burian, D
    Garner, D
    Lewis, RJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 36 (03) : 932 - 938
  • [35] Comparative efficacy of monophasic and biphasic waveforms for transthoracic cardioversion of atrial fibrillation and atrial flutter
    Gurevitz, OT
    Ammash, NM
    Malouf, JF
    Chandrasekaran, K
    Rosales, AG
    Ballman, KV
    Hammill, SC
    White, RD
    Gersh, BJ
    Friedman, PA
    AMERICAN HEART JOURNAL, 2005, 149 (02) : 316 - 321
  • [36] Rounded versus standard biphasic waveforms for catheter atrial defibrillation
    Harbinson, MT
    Trouton, T
    Imam, Z
    Allen, JD
    Dempsey, G
    Anderson, JMC
    Adgey, AAJ
    HEART, 1996, 75 (05) : 82 - 82
  • [37] Effect of electrode polarity on internal defibrillation with monophasic and biphasic waveforms using an endocardial lead system
    Huang, J
    KenKnight, BH
    Walcott, GP
    Walker, RG
    Smith, WA
    Ideker, RE
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1997, 8 (02) : 161 - 171
  • [38] Immediate termination of fibrillation is more likely with biphasic truncated exponential versus monophasic damped sine waveforms used for external defibrillation
    Tovar, OH
    Snyder, DE
    George, AR
    Jones, JL
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 39 (05) : 336A - 336A
  • [40] TRUNCATED BIPHASIC PULSES FOR TRANSTHORACIC DEFIBRILLATION
    BARDY, GH
    GLINER, BE
    KUDENCHUK, PJ
    POOLE, JE
    DOLACK, GL
    JONES, GK
    ANDERSON, J
    TROUTMAN, C
    JOHNSON, G
    CIRCULATION, 1995, 91 (06) : 1768 - 1774