Multi-wavelength spectrophotometric determination of Cr(VI) in water with ABTS

被引:36
|
作者
Fan, Wenjuan [1 ]
Qiao, Junlian [1 ]
Guan, Xiaohong [1 ,2 ]
机构
[1] Tongji Univ, Coll Environm Sci & Engn, State Key Lab Pollut Control & Resources Reuse, Shanghai 200092, Peoples R China
[2] Jinan Univ, Sch Environm, Guangzhou Key Lab Environm Exposure & Hlth, Guangzhou 510632, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
Cr(VI); ABTS; Oxidation; Determination; ATOMIC-ABSORPTION-SPECTROMETRY; TANNERY WASTE-WATER; HEXAVALENT CHROMIUM; CHEMILUMINESCENCE DETECTION; PHOTOMETRIC-DETERMINATION; OXIDATIVE-DEGRADATION; EMISSION-SPECTROMETRY; ORGANIC POLLUTANTS; HYDROGEN-PEROXIDE; NATURAL-WATERS;
D O I
10.1016/j.chemosphere.2016.11.153
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A new method for Cr(VI) (0.025-8.00 mg/L) determination based on the reaction of Cr(VI) and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) (ABTS) in aqueous solutions was developed. The colorless ABTS reacted with Cr(VI) under strong acidic conditions ([H+] = 3.0 or 6.0 M) producing a stable colored radical ABTS(center dot+), which could be measured spectrophotometrically at 415, 649 or 732 nm. The absorbance increase at these three wavelengths for ABTS(center dot+) generation were all linear (less than 1.0% deviation) with respect to the amount of added Cr(VI) and the sensitivity were 1.099 x 10(5), 3.720 x 10(4), and 4.150 x 10(4) M-1 cm(-1) of added Cr(VI) at 415, 649 or 732 nm, respectively. Cr(VI) of 0.025 mg/L below the discharge standard of drinking water could be detected with the method quantitatively and 0.002 mg/L Cr(VI) was determined qualitatively. The molar absorptivity of ABTS(center dot+) generated was determined to be (3.69 +/- 0.01) x 10(4) M-1 cm(-1) at 415 nm and the reaction between Cr(VI) and ABTS had a stoichiometric factor of 1:3 in excess of ABTS. The absorbance of generated ABTS(center dot+) was found to be stable in deionized water or wastewater and Cr(VI) spiked in wastewater could be determined accurately. The ABTS method also had a good anti-interference performance against Co(II) ions. Moreover, the ABTS method could be successfully used in the Cr(VI)-S(IV) system for Cr(VI) determination. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:460 / 467
页数:8
相关论文
共 50 条
  • [41] MULTI-WAVELENGTH DETERMINATION OF COBALT BY TUNGSTEN COIL ATOMIC EMISSION SPECTROMETRY
    Donati, George L.
    Gonzales, Mario H.
    Nobrega, Joaquim A.
    Jones, Bradley T.
    ANALYTICAL LETTERS, 2010, 43 (10-11) : 1723 - 1733
  • [42] Online Spectrophotometric Determination of Cr(III) and Cr(VI) in Tannery Wastewater by LPIC-FIA
    Chen Shujuan
    Liu, Ning
    Zhang, Xinshen
    Yang, Dongjing
    Pang, Hemei
    JOURNAL OF THE SOCIETY OF LEATHER TECHNOLOGISTS AND CHEMISTS, 2013, 97 (01): : 18 - 24
  • [43] RAPID SPECTROPHOTOMETRIC DETERMINATION OF URANIUM(VI) IN SEA-WATER
    SHIJO, Y
    SAKAI, K
    BUNSEKI KAGAKU, 1982, 31 (11) : E395 - E400
  • [44] Determination of trace Cr (III) and Cr (VI) in water samples with total differential spectrophotometric method after separation and preconcentration with levextrel resin
    Guo, FQ
    Huang, LF
    Liang, YZ
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2003, 31 (10) : 1250 - 1252
  • [45] Multi-wavelength spectrophotometric analysis for detection of xanthochromia in cerebrospinal fluid and accuracy for the diagnosis of subarachnoid hemorrhage
    Smith, Andrew
    Wu, Alan H. B.
    Lynch, Kara L.
    Ko, Nerissa
    Grenache, David G.
    CLINICA CHIMICA ACTA, 2013, 424 : 231 - 236
  • [46] Normalization of Quantitative Analysis for Bacteria Multi-Wavelength Transmission Spectroscopy in Water
    Hu Yuxia
    Zhao Nanjing
    Gan Tingting
    Duan Jingbo
    Meng Deshuo
    Liu Jianguo
    Liu Wenqing
    ACTA OPTICA SINICA, 2018, 38 (04)
  • [47] Measurement of dermal water content using a multi-wavelength optical sensor
    Mamouei, M.
    Qassem, M.
    Razban, M.
    Kyriacou, P. A.
    42ND ANNUAL INTERNATIONAL CONFERENCES OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY: ENABLING INNOVATIVE TECHNOLOGIES FOR GLOBAL HEALTHCARE EMBC'20, 2020, : 4353 - 4356
  • [48] SPECTROPHOTOMETRIC DETERMINATION OF MOLYBDENUM(VI)
    ARUNACHA.MK
    KUMARAN, MK
    TALANTA, 1974, 21 (05) : 355 - 358
  • [49] Wavelength interchange in multi-wavelength optical transport networks
    Baroni, S
    Korotky, SK
    Bayvel, P
    IOOC-ECOC 97 - 11TH INTERNATIONAL CONFERENCE ON INTEGRATED OPTICS AND OPTICAL FIBRE COMMUNICATIONS / 23RD EUROPEAN CONFERENCE ON OPTICAL COMMUNICATIONS, VOL 3, 1997, (448): : 164 - 167
  • [50] THE COMPLEXATION OF CR(III) AND CR(VI) WITH FLAVONES IN MICELLAR MEDIA AND ITS USE FOR THE SPECTROPHOTOMETRIC DETERMINATION OF CHROMIUM
    ALVAREZ, MJG
    GARCIA, MED
    SANZMEDEL, A
    TALANTA, 1989, 36 (09) : 919 - 923