摘要
Purpose: We conducted this study toward validating confocal scanning laser Doppler flowmetry (SLDF), a new noninvasive technique for measuring retinal and optic nerve head hemodynamics. Methods: We designed a model flow system using a glass capillary coupled to a microlitre syringe driven by an infusion pump. Eleven capillaries with parallel walls (internal diameters ranging 705 to 25 mu m) were used. The capillaries were perfused with skim milk over a range of pump flow rates. At each flow rate, measurements were made with the Heidelberg Retina Flowmeter (HRF) to study the relationship between HRF-measured flow and actual flow. The initial experiments (n = 2) were conducted to establish the approximate velocity operating range of the HRF with single HRF measurements across a wide range of flow rates, whereas the subsequent experiments (n = 9) were concentrated within this operating range with five HRF measurements at each flow rate. Results: When pump flow rates were converted to actual velocity at the measurement point far the initial experiments, the velocity operating range of the HRF was similar to 0.08 to 1.0 mm/s. For velocities of >1 mm/s, HRF measured velocity was not linearly related to actual velocity. Within the operating range, there was a highly significant linear relationship between HRF-measured flow and actual flow (0.935 less than or equal to r less than or equal to 0.990, p < 0.001). When the curves of HRF-measured velocity versus actual velocity for the different experiments were plotted, they largely superimposed. The variability of the HRF measurements was between 3.57% and 4.05% and was independent of flow rate. Conclusions: SLDF measures reliably and linearly within a given operating range.
引用
收藏
页码:237 / 245
页数:9
相关论文
共 50 条
  • [41] Evaluation of skin blood flow by laser Doppler flowmetry
    Eun, HC
    CLINICS IN DERMATOLOGY, 1995, 13 (04) : 337 - 347
  • [42] Two-dimensional mapping of macular blood flow in high myopia by scanning laser doppler flowmetry
    Shih, YF
    Hwang, JK
    Wang, TH
    Lin, LLK
    Hung, PT
    Chen, MS
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 622 - 622
  • [43] Variability of measurements in the optic nerve head and peripapillary retinal blood flow by scanning laser Doppler flowmetry
    Chung, ES
    Kim, DM
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1210 - 1210
  • [44] Diurnal blood flow change of optic disc and macula in normal subjects by scanning laser Doppler flowmetry
    Wang, TH
    Hung, PT
    Hwang, JK
    Shih, YF
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1996, 37 (03) : 1218 - 1218
  • [45] Retinal blood flow in branch retinal vein occlusion using scanning laser doppler flowmetry.
    Avila, CP
    Mueller, AJ
    Bartsch, DU
    Freeman, WR
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1997, 38 (04) : 4885 - 4885
  • [46] Retinal blood flow measurements in branch retinal vein occlusion using scanning laser Doppler flowmetry
    Avila, CP
    Bartsch, DU
    Bitner, DG
    Cheng, LY
    Mueller, AJ
    Karavellas, MP
    Freeman, WR
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1998, 126 (05) : 683 - 690
  • [47] Depth of penetration of scanning laser Doppler flowmetry in the primate optic nerve
    Wang, L
    Cull, G
    Cioffi, GA
    ARCHIVES OF OPHTHALMOLOGY, 2001, 119 (12) : 1810 - 1814
  • [48] Reliability of retinal microcirculation measurements by scanning laser Doppler flowmetry in humans
    Bagnis, Alessandro
    Pontremoli, Roberto
    Iester, Michele
    JOURNAL OF HYPERTENSION, 2012, 30 (06) : 1265 - 1266
  • [49] Reliability of different image analysis methods for scanning laser Doppler flowmetry
    Kreis, Andreas J.
    Nguyen, Thanh
    Rogers, Sophie
    Wang, Jie Jin
    Harazny, Joanna
    Michelson, Georg
    Farouque, H. M. Omar
    Wong, Tien Y.
    CURRENT EYE RESEARCH, 2008, 33 (5-6) : 493 - 499
  • [50] Reproducibility of scanning laser Doppler flowmetry in the rat retina and optic nervehead
    Tsujikawa, A
    Kiryu, J
    Nonaka, A
    Yamashiro, K
    Ogura, Y
    Honda, Y
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2000, 44 (03) : 257 - 262