Application of surge arresters for the protection of SF6 substations

被引:1
|
作者
Hamza, ASHA
机构
[1] Electrical Engineering Department, Faculty of Engineering, Shoubra, Cairo
关键词
electrical power systems; gas insulated substation; protection; surge arresters;
D O I
10.1016/0196-8904(96)00015-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
Sulphur hexafluoride (SF6) gas-insulated substations (GIS) are exposed to the same types of overvoltages as conventional substations, such as lightning overvoltages, switching overvoltages and temporary overvoltages. Possible means to limit overvoltages in a GIS are active gap (SIG) surge arresters and metal oxide (ZnO) surge arresters. The objective of this work is to study the effects of the system configuration on the performance of these two types of overvoltage limiting devices. The results obtained from the study are presented and discussed, and some general conclusions are suggested. Copyright (C) 1996 Elsevier Science Ltd
引用
收藏
页码:131 / 149
页数:19
相关论文
共 50 条
  • [21] The Influence of Atmospheric Overvoltages on High-Voltage SF6 Substations
    Vukasovic, Vedran
    Baus, Zoran
    Barukcic, Marinko
    INTERNATIONAL JOURNAL OF ELECTRICAL AND COMPUTER ENGINEERING SYSTEMS, 2011, 2 (01) : 17 - 24
  • [22] SURGE PROTECTION OF AN SF6 GAS-INSULATED SUBSTATION SUPPLIED BY PIPE-TYPE CABLES
    KOEPFINGER, JL
    BACVAROV, DC
    ROCAMORA, RG
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1978, 97 (06): : 2282 - 2290
  • [23] A RESONANT SURGE FIELD-TEST FOR SF6 SWITCHGEAR
    BOGGS, SA
    KIRKBY, P
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1981, 100 (04): : 1881 - 1884
  • [24] LIGHTNING AND SURGE PROTECTION OF SUBSTATIONS - REPLY
    CARPENTER, RB
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1995, 31 (01) : 173 - 174
  • [26] Electrical Faults Mastery in High Voltage SF6 Insulated Substations.
    Bernard, Gilles
    RGE, Revue Generale de l'Electricite, 1982, (04): : 231 - 249
  • [27] Substations SF6 circuit breakers: Reliability evaluation based on equipment condition
    Vianna, Elaine A. L.
    Abaide, Aizenira R.
    Canha, Luciane N.
    Miranda, Vladimiro
    ELECTRIC POWER SYSTEMS RESEARCH, 2017, 142 : 36 - 46
  • [28] EXPERIENCE WITH SF6 GAS-INSULATED SUBSTATIONS AND PROPOSALS FOR IMPROVED RELIABILITY
    LINDSAY, C
    HICK, M
    IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (09): : 2596 - 2604
  • [29] ESTIMATION OF BURN-THROUGH PROBABILITY IN SF6 INSULATED SUBSTATIONS.
    Chu, F.Y.
    Ford, G.L.
    Law, C.K.
    SAE Preprints, 1981,
  • [30] Environmental and economic impact of SF6 leakage on ENEL-CODENSA substations
    Castro Aranda, Ferley
    Garcia, Rodolfo
    Ceron Piamba, Andres Felipe
    Mailhe, Benjamin
    REVISTA INTERNACIONAL DE METODOS NUMERICOS PARA CALCULO Y DISENO EN INGENIERIA, 2022, 38 (02):