A combined sensor for simultaneous high resolution 2-D imaging of oxygen and trace metals fluxes

被引:40
|
作者
Stahl, Henrik [1 ]
Warnken, Kent W. [2 ]
Sochaczewski, Lukasz [2 ]
Glud, Ronnie N. [1 ,3 ,4 ]
Davison, William [2 ]
Zhang, Hao [2 ]
机构
[1] Dunstaffnage Marine Lab, Scottish Assoc Marine Sci, Oban PA34 4NB, Argyll, Scotland
[2] Univ Lancaster, Dept Environm Sci, Lancaster LA1 4YQ, England
[3] Univ So Denmark, Inst Biol, DK-5230 Odense M, Denmark
[4] Nord Ctr Earth Evolut NordCee, DK-5230 Odense M, Denmark
来源
关键词
DIFFUSIVE GRADIENTS; MARINE-SEDIMENTS; THIN-FILMS; PERFORMANCE-CHARACTERISTICS; PORE WATERS; SIMULTANEOUS RELEASE; GEL PROBES; DYNAMICS; O-2; MN;
D O I
10.4319/lom.2012.10.389
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
A new sandwich sensor, consisting of an O-2 planar optode overlain by a thin (90 mu m) DGT layer is presented. This sensor can simultaneously resolve 2-D O-2 dynamics and trace metal fluxes in benthic substrates at a high spatial resolution. The DGT layer accumulates metals on a small particle size (0.2 mu m) chelating resin and records the locally induced trace metal flux during the deployment, whereas the planar optode resolves the O-2 dynamic in near real time at the same location in the sediment. Despite its ultrathin composition, the DGT layer has high carrying capacity for trace metals with no saturation problems during application to typical coastal-or contaminated sediments. Combined with laser ablation, accumulated metal fluxes could be resolved at a resolution of similar to 200 mu m, whereas the O-2 images had a resolution of similar to 100 mu m. A 2-D diffusion-reaction model showed that the enhanced smearing and reduced response time of the O-2 signal associated with the additional DGT layer were marginal. To test sensor performance at realistic conditions, it was applied to an artificial burrow system consisting of permeable dialysis tubing flushed with oxygenated seawater. The measurements demonstrated localized mobilization of Ni, Cu, and Pb close to the burrow wall, where O-2 was elevated. The latter was also confirmed for Cu and Pb in natural sediments irrigated by the polychaete Hediste diversicolor. The sandwich sensor has great potential for investigating interrelations between O-2 d ynamics and metal mobilization in complex benthic systems such as burrows, rhizospheres, permeable sands, and microbial mats.
引用
收藏
页码:389 / 401
页数:13
相关论文
共 50 条
  • [21] High-Resolution 3-D Refractive Index Tomography and 2-D Synthetic Aperture Imaging of Live Phytoplankton
    Lee, SangYun
    Kim, Kyoohyun
    Mubarok, Adam
    Panduwirawan, Adisetyo
    Lee, KyeoReh
    Lee, Shinhwa
    Park, HyunJoo
    Park, YongKeun
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2014, 18 (06) : 691 - 697
  • [22] High-resolution computation of 2-D motion from sonogram
    Osanai, Y
    Tagawa, N
    Minagawa, A
    Moriya, T
    Minohara, S
    [J]. 2002 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2002, : 1777 - 1781
  • [23] A 2-D robust high-resolution frequency estimation approach
    Berthoumieu, Y
    El Ansari, M
    Aksasse, B
    Donias, M
    Najim, M
    [J]. SIGNAL PROCESSING, 2005, 85 (06) : 1165 - 1188
  • [24] 3-D Super-Resolution Ultrasound Imaging With a 2-D Sparse Array
    Harput, Sevan
    Tortoli, Piero
    Eckersley, Robert J.
    Dunsby, Chris
    Tang, Meng-Xing
    Christensen-Jeffries, Kirsten
    Ramalli, Alessandro
    Brown, Jemma
    Zhu, Jiaqi
    Zhang, Ge
    Leow, Chee Hau
    Toulemonde, Matthieu
    Boni, Enrico
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2020, 67 (02) : 269 - 277
  • [25] High resolution numerical simulation of the structure of 2-D gaseous detonations
    Mahmoudi, Y.
    Mazaheri, K.
    [J]. PROCEEDINGS OF THE COMBUSTION INSTITUTE, 2011, 33 : 2187 - 2194
  • [26] Quantitative 2-D proteomics imaging with high depth of coverage based upon high resolution separations and accurate mass measurements
    Smith, Richard D.
    Petyuk, Vlad
    Qian, Wei-Jun
    Camp, David G.
    Liu, Tao
    Adkins, Joshua A.
    [J]. ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2006, 231
  • [27] In-Pixel Aperture CMOS Image Sensor for 2-D and 3-D Imaging
    Choi, Byoung-Soo
    Kim, Sang-Hwan
    Lee, Jimin
    Seong, Donghyun
    Shin, Jang-Kyoo
    Lim, Jinyeon
    Chang, Seunghyuk
    Park, Jongho
    Lee, Sang-Jin
    Kyung, Chong-Min
    [J]. IEEE SENSORS JOURNAL, 2018, 18 (22) : 9163 - 9168
  • [28] High-resolution simultaneous voltage and Ca2+imaging
    Vogt, Kaspar E.
    Gerharz, Stephan
    Graham, Jeremy
    Canepari, Marco
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 2011, 589 (03): : 489 - 494
  • [29] Simultaneous 2-D analysis of multiple fluorescent probes using multispectral imaging microscopy
    Sabharwal, YS
    Hopkins, MF
    Lynch, RM
    Donaldson, LT
    [J]. SYSTEMS AND TECHNOLOGIES FOR CLINICAL DIAGNOSTICS AND DRUG DISCOVERY II, PROCEEDINGS OF, 1999, 3603 : 122 - 128
  • [30] Development and implementation of crossed-sine wavefront sensor for simultaneous high spatial resolution imaging
    Feng, Yan
    Henault, Francois
    Schreiber, Laura
    Spang, Alain
    [J]. ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION IV, 2020, 11451