Development of Failure Detection System Based on Vibration Signal for Smart Artificial Heart: in Vitro Study

被引:0
|
作者
Tsujimura, Shinichi [1 ]
Kuwabara, Takashi [1 ]
Koguchi, Harutoshi [1 ]
Yamane, Takashi [2 ]
Tsutsui, Tatsuo [3 ]
Sankai, Yoshiyuki [1 ]
机构
[1] Univ Tsukuba, Syst & Informat Engn, 1-1-1 Tennoudai, Tsukuba, Ibaraki 3058573, Japan
[2] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki, Japan
[3] Univ Tsukuba, Inst Clin Med, Tsukuba, Ibaraki, Japan
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To realize safe and effective medical treatment for patients with implantable artificial hearts, we have developed a smart artificial heart (SAH). The SAH can grasp the mechanical condition of the artificial heart and the physiological condition of the patient. The purpose of this study is to develop a failure detection system based on the vibration signal from artificial heart in order to enhance the ability of failure detection for the SAH. We suppose this vibration signal reflects not only the mechanical condition of the artificial heart but also a part or the physiological condition of the patient. The developed failure detection system is composed of a vibration sensor unit and a failure detection algorithm. The algorithm has a standard frequency pattern, which Is made from the vibration signal of good condition of both the artificial heart and patient. Observing the difference from the standard frequency pattern, the algorithm detects failure conditions. Therefore, this algorithm does not need prior knowledge of vibration characteristics corresponding to failures. After confirming that the vibration signal are affected by pump speed and pulsation in two kinds of mock circulatory loops, we performed thrombogenesis detection by using the failure detection system in mock circulatory loop with sheep blood. As a result, this system indicated a possibility of detecting the Initial sign of thrombogenesis earlier than current signal. In conclusion, we think that this failure detection system can cooperate with other sensor systems of the SAH and enhance the ability of failure detection for the SAH.
引用
收藏
页码:697 / +
页数:2
相关论文
共 50 条
  • [21] A Smart System of Malware Detection Based on Artificial Immune Network and Deep Belief Network
    Dung Hoang Le
    Nguyen Thanh Vu
    Tuan Dinh Le
    INTERNATIONAL JOURNAL OF INFORMATION SECURITY AND PRIVACY, 2021, 15 (01) : 1 - 25
  • [22] Development and clinical validation of an artificial intelligence-based decision support system for predicting risk, diagnosis, and progression of heart failure (STRATIFYHF): a study protocol
    Charman, S.
    Okwose, N. C.
    Groenewegen, A.
    Tafelmeier, M.
    Banerjee, P.
    Fernandez, O.
    Zamorano, J. L.
    Bravo, M. Jimenez-Blanco
    Maier, L. S.
    Olivotto, I.
    Rutten, F. H.
    Mant, J.
    Velicki, L.
    Seferovic, P. M.
    Jakovljevic, D. G.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 166 - 166
  • [23] Vibration signal acquisition and computer simulation detection of mechanical equipment failure
    Wang, Yonggang
    Jagota, Vishal
    Makhatha, Mamookho Elizabeth
    Kumar, Pawan
    NONLINEAR ENGINEERING - MODELING AND APPLICATION, 2022, 11 (01): : 207 - 214
  • [24] In vitro controllability of the MagScrew total artificial heart system
    Weber, S
    Doi, K
    Massiello, AL
    Byerman, BP
    Takagaki, M
    Fukamachi, K
    Donahue, A
    Chapman, P
    Hirschman, G
    Vitale, N
    Smith, WA
    ASAIO JOURNAL, 2002, 48 (06) : 606 - 611
  • [25] Intelligent Vibration Signal Diagnostic System Using Artificial Neural Network
    Lin, Chang-Ching
    Shieh, Shien-Chii
    ICICTA: 2009 SECOND INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTATION TECHNOLOGY AND AUTOMATION, VOL I, PROCEEDINGS, 2009, : 346 - 349
  • [26] Vibration Signal Based Abnormal Gait Detection and Recognition
    Chen, Juanjuan
    Wang, Chengliang
    Liu, Yiluo
    IEEE ACCESS, 2024, 12 : 89845 - 89855
  • [27] Heart failure detection from electrocardiogram using artificial intelligence
    Ranjbar, A. Arian
    Ravn, J.
    Schirmer, H.
    EUROPEAN JOURNAL OF HEART FAILURE, 2024, 26 : 603 - 603
  • [28] Study of the Ballistocardiogram signal in life detection system based on radar
    Lu Guohua
    Wang Jianqi
    Yue Yu
    Jing Xijing
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 2191 - 2194
  • [29] An artificial intelligence-based smart health system for biological cognitive detection based on wireless telecommunication
    Babu, Manikam
    Jesudas, Thangaraju
    COMPUTATIONAL INTELLIGENCE, 2022, 38 (04) : 1365 - 1378
  • [30] Development and assessment of machine learning based heart disease detection using imbalanced heart sound signal
    Rath, Adyasha
    Mishra, Debahuti
    Panda, Ganapati
    Pal, Madhumita
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2022, 76