Casper vs. Closed-Cell Stent Carotid Artery Stenting Randomized Trial

被引:7
|
作者
Vanzin, Jose Ricardo [1 ,4 ]
de Castro-Afonso, Luis Henrique [4 ]
Santos, Moema Nene [2 ]
Manzato, Luciano Bambini [1 ]
Nakiri, Guilherme Seizem [4 ]
Monsignore, Lucas Moretti [4 ]
Trivelato, Felipe Padovani [3 ,4 ]
Rezende, Marco Tulio Salles [3 ,4 ]
Pontes-Neto, Octavio Marques [4 ]
Abud, Daniel Giansante [4 ]
机构
[1] Fed Univ South Frontier, Med Sch Passo Fundo, Div Intervent Neuroradiol, Rua Teixeira Soares 640, BR-99080020 Passo Fundo, RS, Brazil
[2] Fed Univ South Frontier, Med Sch Passo Fundo, Div Hematol, Passo Fundo, RS, Brazil
[3] Felicio Rocho Hosp, Div Intervent Neuroradiol, Belo Horizonte, MG, Brazil
[4] Univ Sao Paulo, Med Sch Ribeirao Preto, Div Intervent Neuroradiol, Ribeirao Preto, SP, Brazil
关键词
Carotid artery angioplasty stenting; Embolic protection devices; Casper stent; Ischemic brain lesions; Magnetic resonance imaging; LAYER MICROMESH STENT; BRAIN-LESIONS; ENDARTERECTOMY; PLAQUE; MULTICENTER; PROTECTION; GUIDELINES; DESIGN;
D O I
10.1007/s00062-020-00937-8
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective The aim of this trial was to compare the efficacy of closed-cell stents with Casper stents during carotid angioplasty stenting (CAS). Methods This was a randomized superiority trial in which 88 patients were enrolled. The primary end points were the incidence, number, and size of new ischemic brain lesions after CAS under distal embolic protection devices (EPD). The secondary end points included stroke, transient ischemic attack (TIA) and myocardial infarction (MI). Ischemic brain lesions were assessed by a diffusion-weighted magnetic resonance image (DW-MRI). Neurological outcomes were evaluated by means of the National Institutes of Health scale score (NIHSS) and the modified Rankin scale (mRS). Results Compared with closed-cell stents (n = 47), Casper stents (n = 41), resulted in no significant reduction in the incidence (44.7% versus 39%,P = 0.592), number (1.3 +/- 1.8 versus 0.9 +/- 1.5,p = 0.444), and size (3.9 +/- 5.8 mm versus 2.8 +/- 4.1 mm, p = 0.353) of new ischemic brain lesions. The global rate of stroke/TIA/MI was (2/88, 2.3%). Two TIA occurred during the hospitalization period, one in each group (1/41, 2.4% vs 1/47, 2.1%). One patient of the Casper group had an asymptomatic in-stent thrombosis. One patient of the control group had a MI (1/47, 2.1%) after discharge. Conclusion The Casper stents did not show superiority in the rate of incidence, number and size of new silent ischemic brain lesions detect by DW-MRI when compared to close cell stents during CAS under distal EPD.
引用
收藏
页码:843 / 852
页数:10
相关论文
共 50 条
  • [31] Carotid Artery Stenosis New Data on Carotid Stenting vs. Endarterectomy
    Leithaeuser, Boris
    AKTUELLE KARDIOLOGIE, 2016, 5 (03) : 167 - U72
  • [32] Regarding "Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting"
    de Borst, Gert J.
    Moll, Frans L.
    Vos, Jan Abert
    JOURNAL OF VASCULAR SURGERY, 2009, 50 (02) : 476 - 477
  • [33] Efficacy of post-dilatation during carotid artery stenting for unstable plaque using closed-cell design stent evaluated by optical coherence tomography
    Harada, Kei
    Kajihara, Masahito
    Sankoda, Yukihiro
    Taniguchi, Syunsuke
    JOURNAL OF NEURORADIOLOGY, 2019, 46 (06) : 384 - 389
  • [34] Randomized Controlled Trial of Cilostazol Addition for In-Stent Restenosis After Carotid Artery Stenting
    Yamagami, Hiroshi
    Ozaki, Tomohiko
    Ogasawara, Kuniaki
    Nagata, Izumi
    Matsumaru, Yuji
    Yoshimura, Shinichi
    Sasaki, Makoto
    Nagatsuka, Kazuyuki
    Minematsu, Kazuo
    Nagai, Yoji
    Sakai, Chiaki
    Matsumoto, Yasushi
    Ezura, Masayuki
    Ishihara, Hideyuki
    Sakai, Nobuyuki
    STROKE, 2024, 55 (12) : 2776 - 2785
  • [35] Carotid Artery Stenting With Dual-Layer Stent Expanding Evidence With a Randomized Trial COMMENT
    Stabile, Eugenio
    Gerardi, Donato
    JACC-CARDIOVASCULAR INTERVENTIONS, 2021, 14 (21) : 2388 - 2390
  • [36] Carotid artery surgery vs. stent: A cardiovascular perspective
    Alhaddad, IA
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (03) : 377 - 384
  • [37] Clinical trial of carotid artery stenting using dual-layer CASPER stent for carotid endarterectomy in patients at high and normal risk in the Japanese population
    Imamura, Hirotoshi
    Sakai, Nobuyuki
    Matsumoto, Yasushi
    Yamagami, Hiroshi
    Terada, Tomoaki
    Fujinaka, Toshiyuki
    Yoshimura, Shinichi
    Sugiu, Kenji
    Ishii, Akira
    Matsumaru, Yuji
    Izumi, Takashi
    Oishi, Hidenori
    Higashi, Toshio
    Iihara, Koji
    Kuwayama, Naoya
    Ito, Yasushi
    Nakamura, Masato
    Hyodo, Akio
    Ogasawara, Kuniaki
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2021, 13 (06) : 524 - 529
  • [38] Reduction of cerebral DWI lesion burden after carotid artery stenting using the CASPER stent system
    Broussalis, Erasmia
    Griessenauer, Christoph
    Mutzenbach, Sebastian
    Pikija, Slaven
    Jansen, Hendrik
    Stevanovic, Valdo
    Killer-Oberpfalzer, Monika
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (01) : 62 - +
  • [39] Carotid artery stenting vs. carotid endarterectomy: a comparative non-randomized study in two university hospitals
    Bakouni, Hamzah
    Nahas, Mohamad A.
    CHIRURGIA-ITALY, 2019, 32 (04): : 172 - 179
  • [40] Regarding "Open-cell versus closed-cell stent design differences in blood flow velocities after carotid stenting" Reply
    Pierce, Damon Scott
    Rosero, Eric B.
    Timaran, Carlos H.
    JOURNAL OF VASCULAR SURGERY, 2009, 50 (02) : 477 - 477