Comparative biomechanical and radiological characterization of osseointegration of a biodegradable magnesium alloy pin and a copolymeric control for osteosynthesis

被引:34
|
作者
Lindtner, Richard A. [1 ]
Castellani, Christoph [2 ]
Tangl, Stefan [3 ,4 ]
Zanoni, Gerald [5 ]
Hausbrandt, Peter [2 ]
Tschegg, Elmar K. [6 ]
Stanzl-Tschegg, Stefanie E. [7 ]
Weinberg, Annelie-Martina [2 ]
机构
[1] Med Univ Innsbruck, Dept Trauma Surg & Sports Med, A-6020 Innsbruck, Austria
[2] Med Univ Graz, Dept Pediat & Adolescent Surg, A-8036 Graz, Austria
[3] Med Univ Vienna, Dept Oral Surg, Karl Donath Lab Hard Tissue & Biomat Res, A-1090 Vienna, Austria
[4] Med Univ Graz, Inst Cell Biol Histol & Embryol, A-8010 Graz, Austria
[5] AUVA Res Ctr, Ludwig Boltzmann Inst Expt & Clin Traumatol, A-1200 Vienna, Austria
[6] Vienna Univ Technol, Inst Solid State Phys, Lab Mat Sci, A-1040 Vienna, Austria
[7] Univ Nat Resources & Appl Life Sci, Inst Phys & Mat Sci, A-1190 Vienna, Austria
关键词
Magnesium alloy; Biodegradable implants; In vivo test; Osseointegration; Mechanical test; BONE-IMPLANT INTERFACE; IN-VITRO CORROSION; ORTHOPEDIC IMPLANTS; FRACTURE FIXATION; VIVO CORROSION; DEGRADATION; BIOCOMPATIBILITY; TITANIUM; DEVICES; STENTS;
D O I
10.1016/j.jmbbm.2013.08.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Magnesium alloys offer great advantages as degradable implant material for pediatric fracture fixation and hold the potential to overcome certain critical shortcomings inherent to currently used degradable (co)polymers. Besides good biocompatibility and appropriate degradation kinetics, sufficient implant anchorage in host bone is critical to prevent implant failure. Bone-implant anchorage of biodegradable magnesium alloys, however, has not yet been related and compared to that of copolymers, their degradable counterparts currently in clinical use. The aim of this study, therefore, was to comparatively assess bone-implant interface strength and the amount of pen-implant bone of a biodegradable magnesium alloy pin (Mg-Y-Nd-HRE) and a self-reinforced copolymeric control (85/15 poly (L-lactic-co-glycolic acid)). To this purpose, push-out testing, microfocus computed tomography (mu CT), histological and scanning electron microscopic examination was performed after 4, 12 and 24 weeks of transcortical implantation in 72 rats. Biomechanical testing revealed significantly higher ultimate shear strength for the magnesium alloy pins than for the copolymeric controls at all 3 timepoints (P <= 0.001 for all comparisons). As evaluated by mu CT, the amount of bone present near the interface and in a wider radius (up to 0.5 mm) around it was higher in the magnesium alloy implants at 4 weeks, without significant differences at 12 and 24 weeks. Histological examination confirmed direct bone-to-implant contact for both implant types. In vivo degradation of implants did not induce any noticeable local or systemic inflammation. This data suggests that the investigated degradable magnesium alloy rod exhibits markedly superior bone-implant interface strength and a greater amount of peri-implant bone than a self-reinforced copolymeric control currently in use; thus it fulfills a crucial prerequisite for its successful clinical deployment as an alternative degradable orthopedic implant material. Further studies, however, are warranted to evaluate the long-term degradation behavior and biocompatibility of the investigated degradable magnesium-based alloy. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:232 / 243
页数:12
相关论文
共 22 条
  • [11] Preparation and characterization of fluoride conversion coating on biodegradable AZ31B magnesium alloy
    Yan, T. (yantting@gmail.com), 1600, National Institute of Optoelectronics (16): : 5 - 6
  • [12] Characterization of indigenously coated biodegradable magnesium alloy primed through novel additive manufacturing assisted investment casting
    Prakash, Chander
    Singh, Sunpreet
    Ramakrishna, Seeram
    MATERIALS LETTERS, 2020, 275
  • [13] Utilizing Synchrotron Radiation for the Characterization of Biodegradable Magnesium Alloys-From Alloy Development to the Application as Implant Material
    Zeller-Plumhoff, Berit
    Tolnai, Domonkos
    Wolff, Martin
    Greving, Imke
    Hort, Norbert
    Willumeit-Roemer, Regine
    ADVANCED ENGINEERING MATERIALS, 2021, 23 (11)
  • [14] Metal-organic complex coating for enhanced corrosion control and biocompatibility on biodegradable magnesium alloy for orthopaedic implants
    Wang, Jiacheng
    Dou, Zhenglong
    Xia, Li
    Huang, Nan
    JOURNAL OF MATERIALS CHEMISTRY B, 2024, 12 (23) : 5661 - 5677
  • [15] Combined anodizing and picosecond laser treatment to control the corrosion rate of biodegradable magnesium alloy AZ31
    O'Brien, Barry J.
    Carroll, William M.
    Conneely, Alan J.
    O'Connor, Gerard M.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART L-JOURNAL OF MATERIALS-DESIGN AND APPLICATIONS, 2014, 228 (04) : 278 - 287
  • [16] Synthesis and Characterization of Polyvinyl Alcohol/Chitosan-Reinforced TiO2 Composite Coating on Biodegradable Magnesium Alloy
    Siddiqui, Muhammad Ali
    Asghar, Muhammad Sajid Ali
    Alam, Syed Shahzaib
    Iqbal, Nimra
    Ullah, Ihsan
    Chen, Junxiu
    Shar, Muhammad Ali
    Alhazaa, Abdulaziz
    Yang, Ke
    Siyal, Sajid Hussain
    JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2025,
  • [17] Preparation and characterization of corrosion inhibitor-loaded micro-arc oxidation/plga composite coating on biodegradable magnesium alloy
    Shi M.-J.
    Li W.-J.
    Ma X.-S.
    Zhu S.-J.
    Guan S.-K.
    Surface Technology, 2021, 50 (02): : 30 - 38
  • [18] Experimental Characterization and Numerical Modeling of the Corrosion Effect on the Mechanical Properties of the Biodegradable Magnesium Alloy WE43 for Orthopedic Applications
    Saconi, Felipe
    Diaz, Geraldine Hincapie
    Vieira, Andre Costa
    Ribeiro, Marcelo Leite
    MATERIALS, 2022, 15 (20)
  • [19] Uniforming outer diameter by control of microstructural evolution for biodegradable ZM21 magnesium alloy tube during dieless drawing
    Du, Peihua
    Kishimoto, Takuma
    Furushima, Tsuyoshi
    JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 2023, 312
  • [20] Characterization of micro-arc oxidation coating post-treated by hydrofluoric acid on biodegradable ZK60 magnesium alloy
    Lin, Xiao
    Tan, Lili
    Wan, Peng
    Yu, Xiaoming
    Yang, Ke
    Hu, Zhuangqi
    Li, Yangde
    Li, Weirong
    SURFACE & COATINGS TECHNOLOGY, 2013, 232 : 899 - 905