For radio interferometric arrays with a sufficient number of redundant spacings the multiplicity of measurements of the same sky visibility can be used to determine both the antenna gains as well as the true visibilities. Many of the earlier approaches to this problem focused on linearized versions of the relation between the measured and the true visibilities. Here, we propose to use a standard non-linear minimization algorithm to solve for both the antenna gains as well as the true visibilities. We show through simulations done in the context of the ongoing upgrade to the Ooty Radio Telescope that the non-linear minimization algorithm is fast compared to the earlier approaches. Further, unlike the most straightforward linearized approach, which works with the logarithms of the visibilities and the gains, the non-linear minimization algorithm leads to unbiased solutions. Finally, we present error estimates for the estimated gains and visibilities. Monte Carlo simulations establish that the estimator is indeed statistically efficient, achieving the Cramer-Rao bound.
引用
收藏
页码:524 / 531
页数:8
相关论文
共 50 条
  • [21] ERROR PROPAGATION IN CALIBRATION CURVES - LINEAR, TRANSFORMED LINEARIZED AND NON-LINEAR CALIBRATIONS
    EBEL, SRG
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1983, 185 (MAR): : 74 - PEST
  • [22] Internal charge injection for the calibration of DEPFETs with non-linear amplification
    Aschauer, Stefan
    Lechner, Peter
    Porro, Matteo
    Sandow, Christian
    Weidenspointner, Georg
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 475 - 481
  • [23] LOWEST LIMIT OF RELIABLE ASSAY MEASUREMENT WITH NON-LINEAR CALIBRATION
    SCHWARTZ, LM
    ANALYTICAL CHEMISTRY, 1983, 55 (08) : 1424 - 1426
  • [24] A simple non-linear technique for secondary calibration of ultrasonic probes
    Gaete-Garreton, L
    Hernandez, YV
    Montoya-Vitini, F
    Juarez, JAG
    SENSORS AND ACTUATORS A-PHYSICAL, 1998, 69 (01) : 68 - 71
  • [25] Non-linear calibration leads to improved correspondence between uncertainties
    Andersen, Jens E. T.
    CHEMIA ANALITYCZNA, 2007, 52 (04): : 715 - 735
  • [26] Application of non-linear automatic optimization techniques for calibration of HSPF
    Iskra, Igor
    Droste, Ronald
    WATER ENVIRONMENT RESEARCH, 2007, 79 (06) : 647 - 659
  • [27] Best non-linear approximation of calibration characteristics of temperature sensors
    Popov, Ya.B.
    Engineering Simulation, 2000, 17 (04): : 599 - 604
  • [28] Robust metric calibration of non-linear camera lens distortion
    Ricolfe-Viala, Carlos
    Sanchez-Salmeron, Antonio-Jose
    PATTERN RECOGNITION, 2010, 43 (04) : 1688 - 1699
  • [29] Research on the Application of PSO Algorithm in Non-linear Camera Calibration
    Wang, Dechao
    Tu, Yaqing
    Zhang, Tienan
    2008 7TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION, VOLS 1-23, 2008, : 4495 - 4499
  • [30] Non-linear feature extraction by redundancy reduction in an unsupervised stochastic neural network
    Deco, G
    Parra, L
    NEURAL NETWORKS, 1997, 10 (04) : 683 - 691