Digital position sensitive discrimination for 2-dimensional scintillation detectors

被引:0
|
作者
Engels, R
Reinartz, R
Reinhart, P
Schelten, J
Halling, H
机构
关键词
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The energy sensitivity of a two-dimensional scintillation gamma detector based on position sensitive photomultipliers has been minimized by a digital differential discrimination unit. Since the photomultiplier gain is position-dependent by 50%, a discrimination unit has been developed where digital upper and lower discrimination levels are set due to the position-dependent photomultiplier gain obtained from calibration measurements. Depending on the spatial resolution there can be up to 65.536 position-sensitive discriminator levels defining energy windows. By this method, narrow discriminator windows can be used for reducing the low and high energy quanta without effecting the sensitivity of the detector. The new discrimination method, its performance and test measurements with gamma rays will be described. Furthermore experimental results are presented.
引用
收藏
页码:721 / 723
页数:3
相关论文
共 50 条
  • [41] Recursive algorithms for digital implementation of neutron/gamma discrimination in liquid scintillation detectors
    Nakhostin, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 672 : 1 - 5
  • [42] Simple algorithms for digital pulse-shape discrimination with liquid scintillation detectors
    Alharbi, T.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 50 - 55
  • [43] THE NEW SCINTILLATION MATERIAL CSI AND ITS APPLICATION TO POSITION-SENSITIVE DETECTORS
    KUBOTA, S
    MURAKAMI, H
    RUAN, JZ
    IWASA, N
    SAKURAGI, S
    HASHIMOTO, S
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 645 - 649
  • [44] EFFICIENCY AND POSITION-RESOLUTION OF 2-DIMENSIONAL POSITION-SENSITIVE MULTIWIRE PROPORTION COUNTERS
    BOLGER, JE
    BRAITHWAITE, WJ
    HOLTKAMP, DB
    KALLNE, J
    THIESSEN, HA
    MORRIS, CL
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (09): : 1169 - 1169
  • [45] NEW STRUCTURE OF 2-DIMENSIONAL POSITION-SENSITIVE SEMICONDUCTOR DETECTOR AND APPLICATION
    YAMAMOTO, K
    YAMAGUCHI, S
    TERADA, Y
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1985, 32 (01) : 438 - 442
  • [46] A DIGITAL DIVIDER WITH EXTENSION BITS FOR POSITION-SENSITIVE DETECTORS
    KOIKE, M
    HASEGAWA, K
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 272 (03): : 840 - 843
  • [47] 2-DIMENSIONAL POSITION-SENSITIVE PHOTODETECTOR FOR HIGH-PRECISION ALIGNMENT
    ARTEMOV, YP
    BAKUMOV, LA
    BLAGIKH, VP
    KHESED, EA
    KHLYAVICH, YL
    MEASUREMENT TECHNIQUES, 1976, 19 (08) : 1111 - 1113
  • [48] Position sensitive detectors
    Huo, Zhen
    Tang, Shicai
    Bandaoti Guangdian/Semiconductor Optoelectronics, 19 (01): : 60 - 66
  • [49] AN ANALYSIS FOR THE ASSESSMENT OF POSITION DISTORTION FOR FAST EXCITATION IN 2-DIMENSIONAL POSITION-SENSITIVE DEVICES (PSDS)
    DUTTA, AK
    HATANAKA, Y
    SOLID-STATE ELECTRONICS, 1991, 34 (08) : 875 - 882
  • [50] Investigation of scintillation light multiplexing for PET detectors based on position sensitive avalanche photodiodes
    Habte, Frezghi
    Olcott, Peter D.
    Levin, Craig S.
    Foudray, Angela M. K.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2027 - 2030