Enhanced accuracy of the microwave field strength measurement in a CW-EPR by pulsed modulation technique

被引:3
|
作者
Rakvin, B. [1 ]
Caric, D. [1 ]
Kveder, M. [1 ]
机构
[1] Rudjer Boskovic Inst, Div Phys Chem, Bijenicka 54, Zagreb, Croatia
关键词
EPR spectroscopy; Microwave field strength; Modulation spectrum; Amplitude modulation EPR; Bloch-Siegert shift; ELECTRON-SPIN-RESONANCE; PARAMAGNETIC-RESONANCE; MAGNETIC-RESONANCE; SATURATION; SPECTRA;
D O I
10.1016/j.jmr.2018.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The microwave magnetic field strength, B-1, in the cavity of a conventional continuous wave electron paramagnetic resonance, CW-EPR, spectrometer was measured by employing modulation sidebands, MS, in the EPR spectrum. MS spectrum in CW-EPR is produced by applying the modulation frequency, omega(rf), which exceeds the linewidth, delta B, given in frequency units. An amplitude-modulated CW-EPR, AM-CW-EPR, was selected as detection method. Theoretical description of AM-CW-EPR spectrum was modified by adding Bloch-Siegert-like shift obtained by taking into account the cumulative effect of the non-resonant interactions between the driving fields and the spin system. This approach enables to enhance the precision of B1 measurement. In order to increase the sensitivity of the method when saturation effects, due to higher intensity of B1, decrease the resolution of AM-CW-EPR spectrum, detection at the second harmonic of CW-EPR has been employed. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [41] A High Accuracy of Magnetometer by Using Independent Directional Magnetic Field Measurement Technique
    Mano, Athirot
    Titiroongruang, Wisut
    AEROSPACE AND MECHANICAL ENGINEERING, 2014, 565 : 133 - 137
  • [42] Method for complex focal field measurement of a high-numerical-aperture lens under CW and pulsed conditions
    Univ of Amsterdam, Amsterdam, Netherlands
    Opt Commun, 1-3 (16-20):
  • [43] Method for complex focal field measurement of a high-numerical-aperture lens under CW and pulsed conditions
    Muller, M
    Buist, AH
    Brakenhoff, GJ
    Squier, J
    OPTICS COMMUNICATIONS, 1997, 138 (1-3) : 16 - 20
  • [44] ANTENNAS FOR MEASUREMENT OF MICROWAVE ELECTROMAGNETIC FIELD BY A LIGHT-MODULATED SCATTERING TECHNIQUE
    TOYONAGA, T
    HORI, M
    MIYAKE, M
    ELECTRONICS & COMMUNICATIONS IN JAPAN, 1972, 54 (11): : 46 - +
  • [45] Microwave Measurement Technique for Evaluating the Polarization of the Electromagnetic Field within a Reverberating Chamber
    Sorrentino, Antonio
    Gil, Jose J.
    Migliaccio, Maurizio
    Ferrara, Giuseppe
    Cappa, Sergio
    2017 INTERNATIONAL APPLIED COMPUTATIONAL ELECTROMAGNETICS SOCIETY SYMPOSIUM - ITALY (ACES), 2017,
  • [46] Cavity-enhanced microwave electric field measurement using Rydberg atoms
    Peng, Yandong
    Wang, Jinling
    Yang, Aihong
    Jia, Zhengmao
    Li, Dehua
    Chen, Bing
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA B-OPTICAL PHYSICS, 2018, 35 (09) : 2272 - 2277
  • [47] Fast and full-field measurement of brake squeal using pulsed ESPI technique
    Krupka, R
    Walz, T
    Ettemeyer, A
    OPTICAL ENGINEERING, 2003, 42 (05) : 1354 - 1358
  • [48] PULSED NMR BY RF TONE-BURST MODULATION - COMPARISON WITH FIELD MODULATION T1 MEASUREMENT TECHNIQUES
    LOOK, DC
    LOCKER, DR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1969, 14 (03): : 332 - &
  • [49] Phase modulation parallel optical delay detector for microwave angle-of-arrival measurement with accuracy monitored
    Cao, Z.
    Wang, Q.
    Lu, R.
    van den Boom, H. P. A.
    Tangdiongga, E.
    Koonen, A. M. J.
    OPTICS LETTERS, 2014, 39 (06) : 1497 - 1500
  • [50] Further development of the pulsed wire technique for magnetic field and focusing strength measurements in long undulators
    Osmanov, NS
    Tolmachev, SV
    Varfolomeev, AA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 407 (1-3): : 443 - 447