Enhanced accuracy of the microwave field strength measurement in a CW-EPR by pulsed modulation technique

被引:3
|
作者
Rakvin, B. [1 ]
Caric, D. [1 ]
Kveder, M. [1 ]
机构
[1] Rudjer Boskovic Inst, Div Phys Chem, Bijenicka 54, Zagreb, Croatia
关键词
EPR spectroscopy; Microwave field strength; Modulation spectrum; Amplitude modulation EPR; Bloch-Siegert shift; ELECTRON-SPIN-RESONANCE; PARAMAGNETIC-RESONANCE; MAGNETIC-RESONANCE; SATURATION; SPECTRA;
D O I
10.1016/j.jmr.2018.01.006
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The microwave magnetic field strength, B-1, in the cavity of a conventional continuous wave electron paramagnetic resonance, CW-EPR, spectrometer was measured by employing modulation sidebands, MS, in the EPR spectrum. MS spectrum in CW-EPR is produced by applying the modulation frequency, omega(rf), which exceeds the linewidth, delta B, given in frequency units. An amplitude-modulated CW-EPR, AM-CW-EPR, was selected as detection method. Theoretical description of AM-CW-EPR spectrum was modified by adding Bloch-Siegert-like shift obtained by taking into account the cumulative effect of the non-resonant interactions between the driving fields and the spin system. This approach enables to enhance the precision of B1 measurement. In order to increase the sensitivity of the method when saturation effects, due to higher intensity of B1, decrease the resolution of AM-CW-EPR spectrum, detection at the second harmonic of CW-EPR has been employed. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:123 / 127
页数:5
相关论文
共 50 条
  • [1] MEASUREMENT OF MICROWAVE FIELD-STRENGTH IN ELECTRON-SPIN-RESONANCE BY A PULSED MODULATION TECHNIQUE
    PERIC, M
    RAKVIN, B
    DULCIC, A
    JOURNAL OF MAGNETIC RESONANCE, 1985, 65 (02) : 215 - 221
  • [2] Modulation sidebands spectra within inhomogeneous CW-EPR line detected by double modulation EPR spectroscopy
    Rakvin, B.
    Caric, D.
    Kveder, M.
    JOURNAL OF MAGNETIC RESONANCE, 2019, 307
  • [3] EXCHANGE OF CHLORIDE BY BROMIDE IN THE MANGANESE PHOTOSYSTEM-II COMPLEX STUDIED BY CW-EPR AND PULSED-EPR
    BOUSSAC, A
    CHEMICAL PHYSICS, 1995, 194 (2-3) : 409 - 418
  • [4] Comparison of CW-EPR and ESEEM technique for determination of water permeability profile in liposome membranes
    V. Noethig-Laslo
    P. Cevc
    D. Arčon
    M. Šentjurc
    Applied Magnetic Resonance, 2004, 27 : 303 - 309
  • [5] Calibration ruler for CW-EPR distance measurement using diradical molecule of rigid structure
    Dong, Guofu
    Wang, Hongyao
    Cong, Jianbo
    Wang, Changzhen
    Guo, Junwang
    Zhang, Tong
    Yang, Jingkui
    Yang, Guoshan
    Wu, Ke
    ACTA BIOCHIMICA ET BIOPHYSICA SINICA, 2015, 47 (05) : 342 - 348
  • [6] Comparison of CW-EPR and ESEEM technique for determination of water permeability profile in liposome membranes
    Noethig-Laslo, V
    Cevc, P
    Arcon, D
    Sentjurc, M
    APPLIED MAGNETIC RESONANCE, 2004, 27 (1-2) : 303 - 309
  • [7] Investigating the Structure and Topology of the Pinholin Membrane Protein Using Pulsed Deer and CW-EPR Spectroscopic Techniques
    Lorigan, Gary A.
    Ahammad, Tanbir
    Khan, Rasal
    BIOPHYSICAL JOURNAL, 2020, 118 (03) : 395A - 395A
  • [8] A NEW TECHNIQUE FOR ACCURATE MEASUREMENT AND ADJUSTMENT OF THE PHASE OF THE MICROWAVE PULSE IN PULSED EPR SPECTROSCOPY
    OHBA, Y
    SATOH, R
    KIKUCHI, T
    YAMAUCHI, S
    IWAIZUMI, M
    JOURNAL OF MAGNETIC RESONANCE SERIES A, 1993, 103 (03) : 282 - 287
  • [9] Accuracy enhanced microwave frequency measurement based on the machine learning technique
    Shi, Difei
    Li, Guangyi
    Jia, Zhiyao
    Wen, Jun
    Li, Ming
    Zhu, Ninghua
    Li, Wei
    OPTICS EXPRESS, 2021, 29 (13) : 19515 - 19524
  • [10] Unsaturated lipid bilayers at cryogenic temperature: librational dynamics of chain-labeled lipids from pulsed and CW-EPR
    Aloi, Erika
    Guzzi, Rita
    Bartucci, Rosa
    PHYSICAL CHEMISTRY CHEMICAL PHYSICS, 2019, 21 (34) : 18699 - 18705