An improved robot calibration method using the modified adjoint error model based on POE

被引:6
|
作者
Jiang, Zizhen [1 ,2 ]
Gao, Wenbin [1 ,2 ]
Yu, Xiaoliu [1 ,2 ]
机构
[1] Anhui Univ Technol, Sch Mech Engn, Maanshan, Peoples R China
[2] Anhui Prov Key Lab Special Heavy Load Robot, Maanshan, Peoples R China
基金
中国国家自然科学基金;
关键词
Product of exponentials (POE); adjoint error model; kinematic calibration; identification; IDENTIFICATION;
D O I
10.1080/01691864.2020.1810772
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
The robot calibration exists many excellent performances by using the POE formula, but it demands extra works to deal with the problems of the joint twist constrains. Thus, the Adjoint error model is proposed to solve these problems, which can be developed further. In this paper, we have modified the Adjoint error model and improved the calibration method. On the one hand, we conduct the formula entirely for the serial robot based on the modified Adjoint error model, so as to give an explicit and unified calibration model. On the other, the method of updating kinematic parameters is also simplified, comparing the previous calibration methods with the Adjoint error model, which can improve the convergence rate and optimize our calibration process. For verifying this method, the simulations on the typical robots of PUMA 560 and SCARA are presented, and the results show that this method has evident superiorities.
引用
下载
收藏
页码:1229 / 1238
页数:10
相关论文
共 50 条
  • [41] Error estimation and grid adaptation using Euler adjoint method
    Kim, Hyoung-Jin
    Takano, Yoshimichi
    Nakahashi, Kazuhiro
    Journal of Aircraft, 1600, 43 (05): : 1317 - 1324
  • [42] Determination of optimal samples for robot calibration based on error similarity
    Tian Wei
    Mei Dongqi
    Li Pengcheng
    Zeng Yuanfan
    Hong Peng
    Zhou Wei
    CHINESE JOURNAL OF AERONAUTICS, 2015, 28 (03) : 946 - 953
  • [43] Determination of optimal samples for robot calibration based on error similarity
    Tian Wei
    Mei Dongqi
    Li Pengcheng
    Zeng Yuanfan
    Hong Peng
    Zhou Wei
    Chinese Journal of Aeronautics, 2015, (03) : 946 - 953
  • [44] Improved method for robot hand-eye system calibration
    Lei, Yunhong
    Wu, Pingdong
    Ma, Shuyuan
    Chen, Zhilong
    Gaojishu Tongxin/Chinese High Technology Letters, 2007, 17 (09): : 934 - 937
  • [45] Improved channel error calibration method for the azimuth multichannel SAR
    Zuo S.
    Sun G.
    Xing M.
    1600, Science Press (44): : 13 - 18
  • [46] A camera calibration method based on nonlinear model and improved planar pattern
    Zhang, YQ
    Wang, ZY
    PROCEEDINGS OF THE 8TH JOINT CONFERENCE ON INFORMATION SCIENCES, VOLS 1-3, 2005, : 707 - 712
  • [47] A novel robot kinematic calibration method based on common perpendicular line model
    Shen, Chen
    Chen, Youping
    Chen, Bing
    Qiao, Yu
    INDUSTRIAL ROBOT-THE INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH AND APPLICATION, 2018, 45 (06): : 766 - 775
  • [48] A new calibration method for enhancing robot position accuracy by combining a robot model-based identification approach and an artificial neural network-based error compensation technique
    Hoai-Nhan Nguyen
    Phu-Nguyen Le
    Kang, Hee-Jun
    ADVANCES IN MECHANICAL ENGINEERING, 2019, 11 (01)
  • [49] Accounting for model error in data assimilation using adjoint models
    Griffith, AK
    Nichols, NK
    COMPUTATIONAL DIFFERENTIATION: TECHNIQUES, APPLICATIONS, AND TOOLS, 1996, : 195 - 204
  • [50] Sensitivity analysis based method for robot calibration
    Kaizerman, S.
    Zak, G.
    Benhabib, B.
    Fenton, R.G.
    Journal of Mechanical Design, Transactions Of the ASME, 1994, 116 (02): : 607 - 613