Miniaturized System with a Facile Isothermal Amplification Microfluidic Chip for Rapid Detection of Zika Viruses

被引:0
|
作者
Chen, Xing [1 ]
Zhang, Lu-lu [1 ]
Cui, Da-fu [1 ]
Yin, Hong [2 ]
机构
[1] Chinese Acad Sci, Inst Elect, State Key Lab Transducer Tech, Beijing 100190, Peoples R China
[2] Chinese Acad Inspect & Quarantine, Beijing 100123, Peoples R China
来源
PROCEEDINGS OF THE 2ND INTERNATIONAL CONFERENCE ON BIOMEDICAL AND BIOLOGICAL ENGINEERING 2017 (BBE 2017) | 2017年 / 4卷
基金
美国国家科学基金会;
关键词
Microfluidic chips; Loop-mediated is other mal amplification (LAMP); Formatting; Miniaturized System;
D O I
暂无
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
A real-time fluorescence detection biomedical miniaturized system with a disposable microfluidic chip was developed for loop-mediated isothermal amplification (LAMP) reactions. The miniaturized system was developed consisting of a mini heating plate, a temperature sensor, a temperature controller and an adjustable mechanical stage. Based on experimental result, the temperature of the heating plate is evenly distributed, and the error of the temperature is less than 1.3%. The microfluidic chip was designed and fabricated by MEMS technology and thin-casting method. The volume of the LAMP reaction was changed from 25 mu L to 2 mu L. The volume of the LAMP reaction was optimized. The nucleic acid of Zika viruses was amplified and detected in real-time mode with our miniatureized system by using above microfluidic chip. From the experiment results, the detection range was from 100 copies to 10(6) copies. This biomedical system has the potential for point-of-care diagnostics (POCT) with the many advantages, such as not high cost, short analysis and detection time, not much reagent and sample consumption and so on.
引用
收藏
页码:404 / 409
页数:6
相关论文
共 50 条
  • [31] Droplet Microfluidic Chip Based Nucleic Acid Amplification and Real-Time Detection of Influenza Viruses
    Prakash, R.
    Pabbaraju, K.
    Wong, S.
    Wong, A.
    Tellier, R.
    Kaler, K. V. I. S.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (02) : B3083 - B3093
  • [32] Rapid isothermal amplification and visual detection of DNA
    Tan, E
    Wong, J
    Niemz, A
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 230 : U409 - U409
  • [33] Rapid and simultaneous detection of common childhood diarrhea viruses by microfluidic-FEN1-assisted isothermal amplification with ultra-high specificity and sensitivity
    Ye, Xin
    Fan, Linlin
    Zhang, Lei
    Wang, Dan
    Ma, Yanfen
    Kong, Jilie
    Fang, Wenjie
    Hu, Jian
    Wang, Xiaoqin
    BIOSENSORS & BIOELECTRONICS, 2024, 264
  • [34] Rapid Detection of Methanol in an Integration Microfluidic Chip
    Wang Yao-Nan
    Liou Ching-Liang
    Wu Ming-Chang
    Tsai Chien-Hsiung
    Fu Lung-Ming
    MEMS/NEMS NANO TECHNOLOGY, 2011, 483 : 364 - +
  • [35] Rapid and simultaneous detection of multiple pathogens in the lower reproductive tract during pregnancy based on loop-mediated isothermal amplification-microfluidic chip
    Xu, Xiaofang
    Jia, Yiguo
    Li, Ruolin
    Wen, Yuting
    Liang, Yuchen
    Lao, Guangjie
    Liu, Xiaojuan
    Zhou, Wei
    Liu, Huawei
    Xie, Jiang
    Wang, Xiaoxia
    Xu, Wenming
    Sun, Qun
    BMC MICROBIOLOGY, 2022, 22 (01)
  • [36] MscI restriction enzyme cooperating recombinase-aided isothermal amplification for the ultrasensitive and rapid detection of low-abundance EGFR mutations on microfluidic chip
    Xu, Shiqi
    Wang, Xinjie
    Wu, Chengyuan
    Zhu, Xueting
    Deng, Xinyi
    Wu, Yue
    Liu, Ming
    Huang, Xingxu
    Wu, Lina
    Huang, He
    BIOSENSORS & BIOELECTRONICS, 2024, 247
  • [37] Rapid Detection of Bacterial Pathogens Causing Lower Respiratory Tract Infections via Microfluidic-Chip-Based Loop-Mediated Isothermal Amplification
    Lai, Jin-Xin
    Qin, Yu-Rong
    Liao, Yi-Wen
    Si, Yu-Ting
    Yuan, Quan
    Huang, Shi-Mei
    Tang, Yu-Rong
    Wang, Ji-Liang
    Wang, Liang
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (205):
  • [38] Rapid and simultaneous detection of multiple pathogens in the lower reproductive tract during pregnancy based on loop-mediated isothermal amplification-microfluidic chip
    Xiaofang Xu
    Yiguo Jia
    Ruolin Li
    Yuting Wen
    Yuchen Liang
    Guangjie Lao
    Xiaojuan Liu
    Wei Zhou
    Huawei Liu
    Jiang Xie
    Xiaoxia Wang
    Wenming Xu
    Qun Sun
    BMC Microbiology, 22
  • [39] Integrated Microfluidic Droplet Digital Isothermal Amplification Enabled Rapid Detection of Urinary Tract Infection Bacteria
    Zou, Jing-Jing
    Li, Zhu-Jun
    Liu, Yun-Fan
    Ouyang, Xiu-Yun
    Wang, Yu
    Cai, Dong-Yang
    He, Xiao-Wei
    Liu, Da-Yu
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2022, 50 (08) : 1158 - 1167
  • [40] Ultrasmall volume molecular isothermal amplification in microfluidic chip with advanced surface processing
    Huang, Guoliang
    Ma, Li
    Yang, Xiaoyong
    Yang, Xu
    9TH INTERNATIONAL CONFERENCE ON PHOTONICS AND IMAGING IN BIOLOGY AND MEDICINE (PIBM 2010), 2011, 277