Concomitant placement of dialysis and infusion catheters in the right internal jugular vein in the intensive care setting: Is it safe?

被引:3
|
作者
Spitzer, Blake [1 ]
Kirkland, Kevin [1 ]
Reyes, Jared [1 ]
Helmer, Stephen D. [1 ,2 ]
Ammar, Chad [1 ]
Subbarao, Chivukula [1 ]
机构
[1] Univ Kansas, Sch Med, Dept Surg, Room 3082,929 N St Francis St, Wichita, KS 67214 USA
[2] Ascens Via Christi Hosp St Francis, Dept Med Educ, Wichita, KS USA
来源
JOURNAL OF VASCULAR ACCESS | 2021年 / 22卷 / 03期
关键词
Dialysis catheter; central venous catheter; thrombosis; line infection; VENOUS CATHETERS; HEMODIALYSIS; COMPLICATIONS; STENOSIS; THROMBOSIS;
D O I
10.1177/1129729820938209
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Purpose: This study examined the safety and efficacy of placing both a central venous dialysis catheter and a central venous catheter for infusion in the right internal jugular vein compared to only a central venous dialysis catheter. Methods: We conducted a retrospective chart review for all adult patients who underwent the placement of the right internal jugular dialysis catheter by a single surgeon. Patients were grouped based on whether they received a tunneled dual lumen dialysis catheter alone or in combination with a central venous infusion catheter in the right internal jugular vein. Catheter-related thrombosis, line infections, line malfunctions, pneumothorax, and need for line replacement were evaluated. Results: There were 97 patients in the dialysis catheter and central venous infusion line group and 63 patients in the dialysis catheter only group. The two groups were not different with regard to age (62.1 +/- 16.3 years vs 57.9 +/- 17.6 years) and gender (47.4% male vs 55.6% male). No significant differences were found in the incidence of thrombosis (1.0 % vs 0.0%,p > 0.999), line infection (2.1% vs 0.0%,p = 0.519), or line malfunctions (2.1% vs 0.0%,p = 0.516) in patients who did or did not have a central venous infusion catheter placed concomitantly with the dialysis catheter, respectively. No patients in either group had a pneumothorax. Conclusions: Although not currently utilized with frequency, these preliminary data indicate that placing both a dual lumen dialysis catheter and central venous infusion catheter in the right internal jugular simultaneously could be a viable option.
引用
收藏
页码:359 / 363
页数:5
相关论文
共 50 条
  • [21] Use of venography at insertion of tunnelled internal jugular vein dialysis catheters reveals significant occult stenosis.
    McIntyre, CW
    Chesterton, L
    Taal, MW
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 725A - 725A
  • [22] Studying alternative approaches for placement of cuffed hemodialysis catheters in hemodialysis patients with bilateral internal jugular vein occlusion
    Gouda, Zaghloul Elsafy
    Emara, Mahmoud Mohamed
    Elbarbary, Hany Said
    Koura, Mahmoud Abdel Aziz
    Elarbagy, Ahmed Rabie
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (03): : 250 - 259
  • [23] Titanium Greenfield filter placement: A retrospective analysis of filter tilting comparing access by right internal jugular vein with right femoral vein
    Zeni, PT
    Roberts, JA
    Price, M
    McFarland, DR
    Ferris, EJ
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1997, 169 (03) : 739 - 741
  • [24] INTERNAL JUGULAR VEIN (IJV) CANNULATION WITH 2 SILASTIC CATHETERS (CT) - A SAFE VASCULAR ACCESS FOR HEMODIALYSIS (HD)
    CANAUD, B
    BERAUD, JJ
    JOYEUX, H
    MION, C
    KIDNEY INTERNATIONAL, 1984, 26 (04) : 544 - 544
  • [25] Report of injury tom right internal jugular vein occurring during tunneled HD catheter placement coincidental with abnormality of internal jugular anatomy
    Morfesis, EA
    DIALYSIS & TRANSPLANTATION, 2004, 33 (10) : 642 - +
  • [26] Safe ECMO femoral decannulation by placement of inferior vena cava filter via internal jugular vein
    Castagna, Luigi
    Maggioni, Elena
    Coppo, Anna
    Cortinovis, Barbara
    Meroni, Veronica
    Sosio, Simone
    Vacirca, Francesco
    Leni, Davide
    Avalli, Leonello
    JOURNAL OF ARTIFICIAL ORGANS, 2016, 19 (03) : 297 - 300
  • [27] Safe ECMO femoral decannulation by placement of inferior vena cava filter via internal jugular vein
    Luigi Castagna
    Elena Maggioni
    Anna Coppo
    Barbara Cortinovis
    Veronica Meroni
    Simone Sosio
    Francesco Vacirca
    Davide Leni
    Leonello Avalli
    Journal of Artificial Organs, 2016, 19 : 297 - 300
  • [28] Internal jugular vein collapsibility index associated with hypovolemia in the intensive care unit patients
    Killu K.
    Coba V.
    Huang Y.
    Andrezejewski T.
    Dulchavsky S.
    Critical Ultrasound Journal, 2010, 2 (1) : 13 - 17
  • [29] Significance of ultrasound-assisted percutaneous cannulation of the internal jugular vein in intensive care
    Louis, C
    Helias, P
    Delacour, JL
    Floriot, C
    Tiberghien-Chatelain, F
    NEPHROLOGIE, 2001, 22 (08): : 513 - 515
  • [30] Predicting the optimal depth of ultrasound-guided right internal jugular vein central venous catheters in neonates
    Montes-Tapia, Fernando
    Hernandez-Trejo, Karla
    Garcia-Rodriguez, Fernando
    Jaime-Reyes, Julio
    Trevino-Garza, Consuelo
    Cardenas-del Castillo, Barbara
    Rodriguez-Balderrama, Isaias
    de la O-Cavazos, Manuel
    JOURNAL OF PEDIATRIC SURGERY, 2020, 55 (09) : 1920 - 1924