Seismic behaviour and design code provisions for predicting the capacity of ductile slender reinforced masonry shear walls

被引:5
|
作者
Robazza, B. R. [1 ]
Brzev, S. [2 ]
Yang, T. Y. [2 ]
Elwood, K. J. [3 ]
Anderson, D. L. [2 ]
McEwen, B. [4 ]
机构
[1] Univ British Columbia, Dept Civil Engn, 2329 W Mall, Vancouver, BC V6T 1Z4, Canada
[2] Univ British Columbia, 2329 W Mall, Vancouver, BC V6T 1Z4, Canada
[3] Univ Auckland, Private Bag 92019, Auckland 1142, New Zealand
[4] Canadian Masonry Contractors Assoc, BC Chapter, 3636 East 4th Ave, Vancouver, BC V5M 1M3, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
STABILITY;
D O I
10.1016/j.engstruct.2020.110992
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Ductile slender reinforced masonry shear walls (DSRMSWs) designed and detailed according to modern seismic design provisions, such as those prescribed by the Canadian masonry design code CSA S304-14, are expected to demonstrate ductile performance when subjected to earthquake effects. These walls have shown good energy dissipation characteristics similar to ductile slender reinforced concrete (RC) shear walls and are used as the seismic-force-resisting system (SFRS) for contemporary buildings in Canada and other countries. These walls are usually slender, with clear height-to-thickness (h(u)/t(w)) ratios that can exceed 20, and height-to-length (h(u)/L-w) aspect ratios usually greater than 1.5. Experimental studies have shown that the response of DSRMSWs subjected to in-plane simulated seismic loading is often affected by multiple failure modes. The initial failure mode often transitions into other failure modes that may govern the response of the DSRMSWs at high ductility demand levels. It is essential that designers understand the prominent DSRMSW failure modes and how they interact with one another to ensure the adequate seismic performance of DSRMSWs. Seismic design and detailing provisions for DSRMSWs contained in international design codes aim for a ductile, well-controlled flexure-dominant seismic response and preclude the occurrence of undesirable shear-dominant failure modes. However, the interaction between various failure modes is usually only accounted for implicitly. The capacity predictions for DSRMSWs based on in-plane ductile failure modes vary between different masonry design codes in terms of the methodology, complexity level, and material resistance factors. This paper provides a detailed comparison of the capacity predictions from the following international codes: CSA S304-14 (Canada); TMS 402/602-16 (USA); NZS 4230:2004 (New Zealand); and Eurocodes 6 and 8 - EN 1996-1-1:2005/EN 1998-1:2004 (EU). The assessment focuses on the following six in-plane flexure-dominant failure modes: (i) ductile flexure, (ii) shear-flexure, (iii) sliding, (iv) toe-crushing, (v) rocking/bond-slip, and (vi) lateral instability, observed in a series of eight full-scale, fully-grouted DSRMSW specimens tested under reversed cyclic loading. The specimens were characterized by varying h(u)/L-w and h(u)/t(w) ratios, the amount and distribution of reinforcement, cross-sectional shape, axial stress level, and type of cyclic loading protocol. The results of this study provide a systematic comparison of the DSRMSW capacity predictions from the different international masonry design codes.
引用
收藏
页数:17
相关论文
共 50 条
  • [31] Seismic Behaviour of Composite Steel Fibre Reinforced Concrete Shear Walls
    Boita, Ioana-Emanuela
    Dan, Daniel
    Stoian, Valeriu
    WORLD MULTIDISCIPLINARY CIVIL ENGINEERING-ARCHITECTURE-URBAN PLANNING SYMPOSIUM - WMCAUS, 2017, 245
  • [32] Seismic performance of shear -critical prefabricated reinforced masonry shear walls with innovative vertical joint connections
    Zhang, Zhiming
    Wang, Fenglai
    Chi, Bin
    ENGINEERING STRUCTURES, 2020, 219
  • [33] Development of seismic fragility functions for close-spaced reinforced masonry shear walls
    Ghaseminia, Seyed Meghdad
    Zahra, Tatheer
    Eslamnia, Hadi
    Thamboo, Julian
    Derakhshan, Hossein
    Thambiratnam, David P.
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [34] Seismic assessment of existing RC shear walls non-compliant with current code provisions
    Christidis, Konstantinos
    Vougioukas, Emmanouil
    Trezos, Konstantinos G.
    MAGAZINE OF CONCRETE RESEARCH, 2013, 65 (17) : 1059 - 1072
  • [35] Effect of boundary element detailing on the seismic performance of reinforced concrete masonry shear walls
    Albutainy, Mohammed
    Galal, Khaled
    ENGINEERING STRUCTURES, 2024, 300
  • [36] Seismic behaviour of L- and T-shaped unreinforced masonry shear walls
    Mordant, C.
    Denoel, V
    Degee, H.
    BRICK AND BLOCK MASONRY: TRENDS, INNOVATIONS AND CHALLENGES, 2016, : 1767 - 1775
  • [37] Seismic design and detailing of reinforced cement concrete buildings including code provisions
    Journal of the Institution of Engineers (India): Civil Engineering Division, 2002, 83 (AUG.): : 93 - 104
  • [38] Seismic performance and height limits of ductile reinforced masonry shear wall buildings with boundary elements
    Aly, Nader
    Galal, Khaled
    ENGINEERING STRUCTURES, 2019, 190 : 171 - 188
  • [39] Study on seismic performance and analysis of shear bearing capacity of damaged brick masonry walls reinforced by single-sided TRC
    Yin S.
    Qu F.
    Wang F.
    Wang B.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2023, 44 : 107 - 115
  • [40] Justification of ACI 446 code provisions for shear design of reinforced concrete beams
    Department of Civil Engineering and Materials Science, Northwestern University, Evanston, IL, United States
    不详
    不详
    不详
    不详
    ACI Struct J, 2007, 5 (601-610):