Comparison of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible - A computed tomography-based three-dimensional finite element analysis

被引:81
|
作者
Barao, V. A. R. [1 ,3 ]
Delben, J. A. [1 ]
Lima, J. [2 ]
Cabral, T. [2 ]
Assuncao, W. G. [1 ]
机构
[1] Univ Estadual Paulista UNESP, Aracatuba Dent Sch, Dept Dent Mat & Prosthodont, Sao Paulo, Brazil
[2] Smarttech Co, Sao Paulo, Brazil
[3] State Univ Campinas UNICAMP, Piracicaba Dent Sch, Dept Prosthodont & Periodontol, Sao Paulo, Brazil
基金
巴西圣保罗研究基金会;
关键词
Dental Implants; Overdenture; Fixed full-arch prosthesis; Biomechanics; Finite element analysis; IMMEDIATELY LOADED IMPLANTS; MARGINAL BONE LOSS; BIOMECHANICAL EVALUATION; ENDOSSEOUS IMPLANTS; ANCHORAGE SYSTEMS; COMPLETE DENTURE; DENTAL IMPLANTS; ORAL IMPLANTS; FOLLOW-UP; STRAINS;
D O I
10.1016/j.jbiomech.2013.02.008
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A finite element analysis was used to compare the effect of different designs of implant-retained overdentures and fixed full-arch implant-supported prosthesis on stress distribution in edentulous mandible. Four models of an human mandible were constructed. In the OR (O'ring) group, the mandible was restored with an overdenture retained by four unsplinted implants with O'ring attachment; in the BC (bar-clip) -C and BC groups, the mandibles were restored with overdentures retained by four splinted implants with bar-clip anchor associated or not with two distally placed cantilevers, respectively; in the FD (fixed denture) group, the mandible was restored with a fixed full-arch four-implant-supported prosthesis. Models were supported by the masticatory muscles and temporomandibular joints. A 100-N oblique load was applied on the left first molar. Von Mises (sigma(vM)), maximum (sigma(max)) and minimum (sigma(min)) principal stresses (in MPa) analyses were obtained. BC-C group exhibited the highest stress values (sigma(vM) = 398.8, sigma(max) = 580.5 and sigma(min) = -455.2) while FD group showed the lowest one (sigma(vM) =128.9, sigma(max) = 580.5 and sigma(min) = -172.1). Within overdenture groups, the use of unsplinted implants reduced the stress level in the implant/prosthetic components (59.4% for sigma(vM) 66.2% for sigma(max) and 57.7% for sigma(min) versus BC-C group) and supporting tissues (maximum stress reduction of 72% and 79.5% for sigma(max), and 15.7% and 85.7% for sigma(min) on the cortical and trabecular bones, respectively). Cortical bone exhibited greater stress concentration than the trabecular bone for all groups. The use of fixed implant dentures and removable dentures retained by unsplinted implants to rehabilitate edentulous mandible reduced the stresses in the periimplant bone tissue, mucosa and implant/prosthetic components. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1312 / 1320
页数:9
相关论文
共 50 条
  • [1] Stress evaluation of different implant lengths on atrophic edentulous mandibles with fixed full-arch implant-supported prosthesis: a finite element analysis
    Benevides, Fernanda
    Cimoes, Renata
    Vajgel, Andre
    Wilmersdorf, Ramiro Brito
    Farias Vajgel, Bruna de Carvalho
    [J]. COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2021, 24 (04) : 358 - 374
  • [2] Influence of implant distribution on the biomechanical behaviors of mandibular implant-retained overdentures: a three-dimensional finite element analysis
    Xiaoling Liao
    Ruitao Cao
    Juan Zhong
    Chunxia Chen
    Shaoxia Pan
    [J]. BMC Oral Health, 24
  • [3] Influence of implant distribution on the biomechanical behaviors of mandibular implant-retained overdentures: a three-dimensional finite element analysis
    Liao, Xiaoling
    Cao, Ruitao
    Zhong, Juan
    Chen, Chunxia
    Pan, Shaoxia
    [J]. BMC ORAL HEALTH, 2024, 24 (01)
  • [4] Influence of implant number on the biomechanical behaviour of mandibular implant-retained/supported overdentures: A three-dimensional finite element analysis
    Liu, Jingyin
    Pan, Shaoxia
    Dong, Jing
    Mo, Zhongjun
    Fan, Yubo
    Feng, Hailan
    [J]. JOURNAL OF DENTISTRY, 2013, 41 (03) : 241 - 249
  • [5] Effect of Framework in an Implant-Supported Full-Arch Fixed Prosthesis: 3D Finite Element Analysis
    Menini, Maria
    Pesce, Paolo
    Bevilacqua, Marco
    Pera, Francesco
    Tealdo, Tiziano
    Barberis, Fabrizio
    Pera, Paolo
    [J]. INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2015, 28 (06) : 627 - 630
  • [6] Mandibular Flexure and Peri-Implant Bone Stress Distribution on an Implant-Supported Fixed Full-Arch Mandibular Prosthesis: 3D Finite Element Analysis
    Martin-Fernandez, Elena
    Gonzalez-Gonzalez, Ignacio
    deLlanos-Lanchares, Hector
    Andres Mauvezin-Quevedo, Mario
    Brizuela-Velasco, Aritza
    Alvarez-Arenal, Angel
    [J]. BIOMED RESEARCH INTERNATIONAL, 2018, 2018
  • [7] Mandibular Flexure and Crestal Bone Stress Distribution on an Implant-Supported Fixed Full Arch Mandibular Prosthesis: Finite Element Analysis in Three Dimensions
    Sharma, Suraj
    Jain, Shashikala
    Gupta, Himanshu
    Gavara, Sai Govind
    Panwar, Pratibha
    Grover, Ramanjeet Kaur
    [J]. CUREUS JOURNAL OF MEDICAL SCIENCE, 2023, 15 (05)
  • [8] Finite element analysis of the effect of cantilever and implant length on stress distribution in an implant-supported fixed prosthesis
    Sertgoz, A
    Guvener, S
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 1996, 76 (02): : 165 - 169
  • [9] A comparative evaluation of stress distribution between an All-on-Four implant-supported prosthesis and the Trefoil implant-supported prosthesis: A three-dimensional finite element analysis study
    Murugaian, Jaisudhaa
    Ganesan, Lambodaran
    Shankar, M. S. Sathya
    Annapoorni, H.
    [J]. THE JOURNAL OF INDIAN PROSTHODONTIC SOCIETY, 2022, 22 (01) : 56 - 64
  • [10] Three-dimensional finite element analysis of occlusal splint and implant connection on stress distribution in implant-supported fixed dental prosthesis and peri-implantal bone
    Marsico, Vivian dos Santos
    Lehmann, Roberto Brunow
    de Assis Claro, Cristiane Aparecida
    Amaral, Marina
    Vitti, Rafael Pino
    Claro Neves, Ana Christina
    da Silva Concilio, Lais Regiane
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2017, 80 : 141 - 148