Reevaluation of the efficacy of preoperative computed tomography-guided hook wire localization: A retrospective analysis

被引:39
|
作者
Yao, Fei [1 ]
Wang, Jian [1 ,2 ]
Yao, Ju [1 ]
Xu, Lei [1 ]
Wang, Jian [1 ,2 ]
Gao, Libing [2 ]
机构
[1] Nanjing Med Univ, Dept Thorac Surg, Affiliated Jiangning Hosp, 168 Gushan Rd, Nanjing 211100, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Dept Radiol, Affiliated Jiangning Hosp, Nanjing, Jiangsu, Peoples R China
关键词
Hook wire localization; Video-assisted thoracic surgery; Pneumothorax; ASSISTED THORACOSCOPIC SURGERY; PULMONARY NODULES; RISK-FACTORS; CT; SAFETY; PNEUMOTHORAX; BRONCHOSCOPY; MANAGEMENT; STATEMENT; RESECTION;
D O I
10.1016/j.ijsu.2018.01.014
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background: Small pulmonary nodules (SPNs) often cannot be accurately located during video-assisted thoracoscopic (VATS) resection, and preoperative computed tomography (CT)-guided localization performed using hook wire placement can be helpful. However, recent studies revealed a trend towards more frequent and severe complications occurring in association with hook wire insertion. The aim of this study is to reevaluate the safety, and reliability of the preoperative CT-guided hook wire localization technique and also identify the risk factors for localization-related pneumothorax. Methods: This retrospective study enrolled 95 patients (with 105 pulmonary nodules) who underwent preoperative CT-guided hook wire localization and followed VATS resection from January 2013 to September 2016. Univariate and multivariate logistic regression analyses were used to identify factors associated with localization-related pneumothorax. Results: All the 105 nodules were successfully localized. Two (1.9%) hook wires dislodged before VATS resection. Mean largest diameter of the nodules was 10.1 mm (range, 3-19 mm). Mean depth from the nearest pleural surface was 11.2 mm (range, 2-38 mm). Mean needle insertion depth was 24.3 mm (range, 4-49 mm), and mean procedure time was 17.3 min (range, 7-48 min). Asymptomatic pneumothorax was observed in 18 patients (18.9%) and hemorrhage in 7 patients (7.4%). Multivariate logistic regression analysis revealed the number of needle insertions (OR 8.893, p = 0.019) as the only significant independent risk factor of pneumothorax. Conclusions: CT-guided hook wire localization is a safe, reliable and convenient technique and can be applied widely to facilitate the resection of SPNs. Simultaneous localization for multiple nodules in ipsilateral lung may be associated with a higher risk of localization-related pneumothorax.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [21] Pre-operative localization of solitary pulmonary nodule with computed tomography-guided hook wire: Experience with 181 patients
    Hanauer, M.
    Perentes, J.
    Krueger, T.
    Ris, H. B.
    Bize, P.
    Schmidt, S.
    Lovis, A.
    Gonzalez, M.
    BRITISH JOURNAL OF SURGERY, 2014, 101 : 22 - 23
  • [22] Systemic air embolism after computed tomography-guided hook wire localization: two case reports and literature review
    Yi, Jung Hoon
    Choi, Pil Jo
    Bang, Jung Hee
    Jeong, Sang Seok
    Cho, Joo Hyun
    JOURNAL OF THORACIC DISEASE, 2018, 10 (01) : E59 - E64
  • [23] Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients
    Hanauer, Matthieu
    Perentes, Jean Yannis
    Krueger, Thorsten
    Ris, Hans-Beat
    Bize, Pierre
    Schmidt, Sabine
    Gonzalez, Michel
    JOURNAL OF CARDIOTHORACIC SURGERY, 2016, 11
  • [24] Pre-operative localization of solitary pulmonary nodules with computed tomography-guided hook wire: report of 181 patients
    Matthieu Hanauer
    Jean Yannis Perentes
    Thorsten Krueger
    Hans-Beat Ris
    Pierre Bize
    Sabine Schmidt
    Michel Gonzalez
    Journal of Cardiothoracic Surgery, 11
  • [25] Presurgical computed tomography-guided localization of lung ground glass nodules: comparing hook-wire and indocyanine green
    Han, Rui
    Wang, Long-Fei
    Teng, Fei
    Lin, Jia
    Xian, Yu-Tao
    Lu, Yun
    Wu, An-Le
    WORLD JOURNAL OF SURGICAL ONCOLOGY, 2024, 22 (01)
  • [26] Presurgical computed tomography-guided localization of lung ground glass nodules: comparing hook-wire and indocyanine green
    Rui Han
    Long-Fei Wang
    Fei Teng
    Jia Lin
    Yu-Tao Xian
    Yun Lu
    An-Le Wu
    World Journal of Surgical Oncology, 22
  • [27] Percutaneous computed tomography-guided localization of pulmonary nodules with hook wire prior to video-assisted thoracoscopic surgery
    Manouvelou, Stamo
    Mosa, Eftychia
    Tolia, Maria
    Tsoukalas, Nikolaos
    Nikolaou, Michail
    Nikolaou, Georgios
    Dountsis, Apostolos
    Andriotis, Efthymios
    Vasilikos, Konstantinos
    Kyrgias, George
    JOURNAL OF BUON, 2019, 24 (01): : 267 - 272
  • [28] Preoperative computed tomography-guided localization for lung nodules: localization needle versus coil
    Huang, Ya-Yong
    Liu, Xia
    Shi, Yi-Bing
    Wang, Tao
    MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2022, 31 (06) : 948 - 953
  • [29] Computed tomography-guided wire localization - An intraoperative tool for head and neck resections
    Horne, SK
    Park, GC
    Dahlen, RT
    Brennan, J
    ARCHIVES OF OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2002, 128 (02) : 187 - 189
  • [30] Computed tomography-guided preoperative localization of small lung nodules with indocyanine green
    Nagai, Keisuke
    Kuriyama, Keiko
    Inoue, Atsuo
    Yoshida, Yuriko
    Takami, Koji
    ACTA RADIOLOGICA, 2018, 59 (07) : 830 - 835