Ex vivo investigations of laser auricular cartilage reshaping with carbon dioxide spray cooling in a rabbit model

被引:5
|
作者
Wu, Edward C. [1 ]
Sun, Victor [1 ]
Manuel, Cyrus T. [1 ]
Protsenko, Dmitriy E. [1 ]
Jia, Wangcun [1 ]
Nelson, J. Stuart [1 ]
Wong, Brian J. F. [1 ]
机构
[1] Univ Calif Irvine, Beckman Laser Inst & Med Clin, Irvine, CA 92612 USA
基金
美国国家卫生研究院;
关键词
Facial plastic surgery; Macrotia; Carbon dioxide spray; Laser cartilage reshaping; NASAL SEPTAL CARTILAGE; PORT-WINE STAIN; ER-YAG LASER; MECHANICAL-BEHAVIOR; STRESS-RELAXATION; ELASTIC-MODULUS; CRYOGEN; PORCINE; IRRADIATION; RESPONSES;
D O I
10.1007/s10103-012-1250-9
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Laser cartilage reshaping (LCR) with cryogen spray cooling is a promising modality for producing cartilage shape change while reducing cutaneous thermal injury. However, LCR in thicker tissues, such as auricular cartilage, requires higher laser power, thus increasing cooling requirements. To eliminate the risks of freeze injury characteristic of high cryogen spray pulse rates, a carbon dioxide (CO2) spray, which evaporates rapidly from the skin, has been proposed as the cooling medium. This study aims to identify parameter sets which produce clinically significant reshaping while producing minimal skin thermal injury in LCR with CO2 spray cooling in ex vivo rabbit auricular cartilage. Excised whole rabbit ears were mechanically deformed around a cylindrical jig and irradiated with a 1.45-mu m wavelength diode laser (fluence 12-14 J/cm(2) per pulse, four to six pulse cycles per irradiation site, five to six irradiation sites per row for four rows on each sample) with concomitant application of CO2 spray (pulse duration 33-85 ms) to the skin surface. Bend angle measurements were performed before and after irradiation, and the change quantified. Surface temperature distributions were measured during irradiation/cooling. Maximum skin surface temperature ranged between 49.0 to 97.6 A degrees C following four heating/cooling cycles. Significant reshaping was achieved with all laser dosimetry values with a 50-70 A degrees C difference noted between controls (no cooling) and irradiated ears. Increasing cooling pulse duration yielded progressively improved gross skin protection during irradiation. CO2 spray cooling may potentially serve as an alternative to traditional cryogen spray cooling in LCR and may be the preferred cooling medium for thicker tissues. Future studies evaluating preclinical efficacy in an in vivo rabbit model are in progress.
引用
收藏
页码:1475 / 1482
页数:8
相关论文
共 50 条
  • [21] Laser-mediated cartilage reshaping with feedback-controlled cryogen spray cooling: Biophysical properties and viability
    Karamzadeh, AM
    Rasouli, A
    Tanenbaum, BS
    Milner, TE
    Nelson, JS
    Wong, BJF
    LASERS IN SURGERY AND MEDICINE, 2001, 28 (01) : 1 - 10
  • [22] Carbon Dioxide Laser-Assisted Cartilage Reshaping Otoplasty: A New Technique for Prominent Ears
    Ragab, Ahmed
    LARYNGOSCOPE, 2010, 120 (07): : 1312 - 1318
  • [23] Minimizing superficial thermal injury using bilateral cryogen spray cooling during laser reshaping of composite cartilage grafts
    Chang, Cheng-Jen
    Cheng, Sally M. H.
    Chiu, Lynn L.
    Wong, Brian J. F.
    Ting, Keen
    LASERS IN SURGERY AND MEDICINE, 2008, 40 (07) : 477 - 482
  • [24] Transmucosal irradiation of septal cartilage with 1.45 laser in ex-vivo rabbit and porcine models
    Protsenko, Dmitry E.
    Wong, Brian J. F.
    LASERS IN SURGERY AND MEDICINE, 2008, : 8 - 8
  • [25] DETERMINING UPPER THERAPEUTIC DOSIMETRY AND CRYOGEN COOLING PARAMETERS FOR LASER CARTILAGE RESHAPING IN THE NEW ZEALAND WHITE RABBIT AURICLE
    Chlebicki, Cara
    Protsenko, Dmitry
    Holden, Paul
    Wong, Brian
    LASERS IN SURGERY AND MEDICINE, 2009, : 1 - 1
  • [26] MECHANICAL STABILITY OF AURICULAR TISSUE FOLLOWING LASER EAR RESHAPING WITH CRYOGEN SPRAY COOLING IN THE NEW ZEALAND WHITE RABBITS USING THE CANDELA SMOOTHBEAM DIODE LASER
    Protsenko, Dmitry
    Chlebicki, Cara
    Wong, Brian
    LASERS IN SURGERY AND MEDICINE, 2009, : 2 - 2
  • [27] Quantification of laser-induced cartilage injury by confocal microscopy in an ex vivo model
    Mainil-Varlet, P
    Monin, D
    Weiler, C
    Grogan, S
    Schaffner, T
    Züger, B
    Frenz, M
    JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2001, 83A (04): : 566 - 571
  • [28] THE BIOLOGICAL EFFECTS OF CARBON-DIOXIDE LASER-SURGERY ON RABBIT ARTICULAR-CARTILAGE
    VANGSNESS, CT
    SMITH, CF
    MARSHALL, GJ
    SWEENEY, JR
    JOHANSEN, E
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1995, (310) : 48 - 51
  • [29] Histomorphological transformation of the auricular cartilage after carbon dioxide laser-assisted Mustardé otoplasty. An experimental study
    Igor Janík
    Ivo Stárek
    Zdeněk Hložek
    Jiří Hubáček
    Radko Novotný
    Jana Dvořáčková
    Lasers in Medical Science, 2009, 24 : 433 - 437
  • [30] Histomorphological transformation of the auricular cartilage after carbon dioxide laser-assisted Mustard, otoplasty. An experimental study
    Janik, Igor
    Starek, Ivo
    Hlozek, Zdenek
    Hubacek, Jiri
    Novotny, Radko
    Dvorackova, Jana
    LASERS IN MEDICAL SCIENCE, 2009, 24 (03) : 433 - 437