Dead-band-free, real-time high-resolution microwave frequency measurement with a multi-comb laser

被引:0
|
作者
Li, Cui [1 ]
Zhao, Xin [1 ]
Li, Ruixiao [1 ]
Li, Ting [1 ]
Hu, Guoqing [1 ]
Yasui, Takeshi [3 ,4 ]
Zheng, Zheng [1 ,2 ]
机构
[1] Beihang Univ, Sch Elect & Informat Engn, Beijing 100083, Peoples R China
[2] Collaborat Innovat Ctr Geospatial Technol, 129 Luoyu Rd, Wuhan 430079, Hubei, Peoples R China
[3] Tokushima Univ, Grad Sch Sci & Technol, 2-1 Minami Josanjima, Tokushima 7708506, Japan
[4] JST, ERATO, MINOSHIMA Intelligent Opt Synthesizer Project, 2-1 Minami Josanjima, Tokushima 7708506, Japan
关键词
DUAL-WAVELENGTH;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Triple-comb pulses generated from one multi-wavelength mode-locked laser enable real-time microwave frequency measurement without the, 'dead-band'. limitation in previous dual-comb schemes. 1.5*10(-10) measurement accuracy is achieved at 20 GHz using a low-cost, compact fiber-optic setup.
引用
下载
收藏
页数:2
相关论文
共 50 条
  • [21] Direct, Real-time, High-resolution Beam profiler for High-power Laser
    Tsunekane, M.
    Sato, K.
    Takahashi, T.
    Yoshino, S.
    Yoshimori, N.
    Ohno, J.
    HIGH-POWER LASER MATERIALS PROCESSING: APPLICATIONS, DIAGNOSTICS, AND SYSTEMS IX, 2020, 11273
  • [22] HIGH-RESOLUTION LASER MICRO-RECORDING SYSTEM WITH REAL-TIME VIEWING
    CHENG, D
    MILLER, RC
    IEEE JOURNAL OF QUANTUM ELECTRONICS, 1973, QE 9 (06) : 676 - 677
  • [24] A high-resolution, four-band SAR testbed with real-time image formation
    Walker, B
    Sander, G
    Thompson, M
    Burns, B
    Fellerhoff, R
    Dubbert, D
    IGARSS '96 - 1996 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM: REMOTE SENSING FOR A SUSTAINABLE FUTURE, VOLS I - IV, 1996, : 1881 - 1885
  • [25] HIGH-RESOLUTION REAL-TIME ULTRASONOGRAPHY OF THE HEAD IN INFANCY
    BABCOCK, DS
    HAN, BK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 135 (03) : 641 - 641
  • [26] High-resolution real-time MRI for vascular interventions
    Terashima, M
    De la pena-Almageur, E
    Nayak, KS
    Yang, PC
    Pauly, JM
    Hu, BS
    McConnell, MV
    CIRCULATION, 2001, 104 (17) : 638 - 638
  • [27] A real-time high-resolution optical SAR processor
    Marchese, Linda
    Doucet, Michel
    Harnisch, Bernd
    Suess, Martin
    Bourqui, Pascal
    Legros, Mathieu
    Desnoyers, Nichola
    Guillot, Ludovic
    Mercier, Luc
    Savard, Maxime
    Martel, Anne
    Chateauneuf, Francois
    Bergeron, Alain
    RADAR SENSOR TECHNOLOGY XIV, 2010, 7669
  • [28] Real-time video mosaicing with a high-resolution microendoscope
    Bedard, Noah
    Quang, Timothy
    Schmeler, Kathleen
    Richards-Kortum, Rebecca
    Tkaczyk, Tomasz S.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (10): : 2428 - 2435
  • [29] A HIGH-RESOLUTION, NEAR REAL-TIME FREQUENCY ESTIMATOR FOR SUB-MICROSECOND PULSES
    MCCORMICK, WS
    IEEE INTERNATIONAL CONFERENCE ON SYSTEMS ENGINEERING ///, 1989, : 33 - 38
  • [30] HIGH-RESOLUTION REAL-TIME ULTRASOUND OF THE CAROTID BIFURCATION
    COOPERBERG, PL
    ROBERTSON, WD
    FRY, P
    SWEENEY, V
    JOURNAL OF CLINICAL ULTRASOUND, 1979, 7 (01) : 13 - 17