Transcranial Doppler test for evaluation of cerebral artery embolism - Microemboli detection

被引:3
|
作者
Jovanovic, Zagorka B. [1 ]
Pavlovic, Aleksandra M. [1 ]
Zidverc-Trajkovic, Jasna J. [1 ]
Mijajlovic, Milija M. [1 ]
Radojicic, Aleksandra P. [1 ]
Covickovic-Sternic, Nadezda M. [1 ]
机构
[1] Klin Ctr Srbije, Inst Neurol, Belgrade 11000, Serbia
关键词
microembolic signals; transcranial Doppler; embolic stroke; TIA;
D O I
10.2298/SARH0806302J
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
About one third of ischaemic cerebrovascular diseases have embolic properties. Because of that, transcranial Doppler (TCD) test for detection of microembolic signals (MES), as the only one method for detection of microemboli, is a very important test for the evaluation of cerebral artery embolism. Cerebral emboli are particles of thrombus or atheromatous plaque, platelet aggregates, lipid or air particles in cerebral circulation, which can occlude arterioles and cause ischaemic transient attack (TIA) or stroke. Most frequently, they derive from exulcerated plaques of the carotid bifurcation or the aortic arch, from the atrial thrombus, prosthetic heart valves, as well as during carotid endarterectomy, arterial stent, aortocoronary by-pass. For MES detection, bilateral monitoring of a. cerebri mediae (ACM) is performed with each probe held in place over a temporal bone. MES are represented as brightly coloured embolic tracks as they pass through the insonated arteries. A computer hard disk provides continuous recording that is replayed for counting embolic signals. Colour intensity or acoustic range indicate the size and structure of MES. MES in the range of one ACM indicate the source of embolism on the ipsilateral carotid artery, while the bilateral detection of MES suggests a cardiogenic source. Indications for TCD detection of MES are the evaluation of pathogenesis and risk for embolic stroke or TIA and assessing the source of embolism. We started applying this method at the Institute of Neurology in Belgrade 2 years ago. We have investigated 78 patients till today and detected MES in 23 patients (28.7%). The Report of the Therapeutics and Technology Assessment Subcommittee of the American Academy of Neurology, 2004, considers that TCD is probably useful for detection of cerebral MES in various cardiovascular and cerebrovascular disorders and procedures.
引用
收藏
页码:302 / 306
页数:5
相关论文
共 50 条
  • [21] THE DETECTION OF MICROEMBOLI IN THE MIDDLE CEREBRAL-ARTERY DURING CARDIOPULMONARY BYPASS - A TRANSCRANIAL DOPPLER ULTRASOUND INVESTIGATION USING MEMBRANE AND BUBBLE OXYGENATORS
    PADAYACHEE, TS
    PARSONS, S
    THEOBOLD, R
    LINLEY, J
    GOSLING, RG
    DEVERALL, PB
    ANNALS OF THORACIC SURGERY, 1987, 44 (03): : 298 - 302
  • [22] Effect of antiplatelet therapy on cerebral microemboli evaluated by transcranial Doppler ultrasonography
    Sakaguchi, M
    Nagatsuka, K
    Naritomi, H
    Sawada, T
    STROKE, 1996, 27 (01) : 80 - 80
  • [23] Detection of microemboli by transcranial Doppler sonography after carotid endarterectomy
    Akiyama, Y
    Todaka, T
    Nomura, M
    Sawada, M
    Morimoto, M
    Kojima, A
    Hashimoto, N
    Yoshimoto, H
    Nagatsuka, K
    NEUROLOGICAL SURGERY, 1997, 25 (09): : 791 - 794
  • [24] Detection and differentiation of cerebral microemboli in patients undergoing major orthopaedic surgery using transcranial Doppler ultrasound
    Kietaibl, C.
    Engel, A.
    Menih, I. Horvat
    Huepfl, M.
    Erdoes, G.
    Kubista, B.
    Ullrich, R.
    Windhager, R.
    Markstaller, K.
    Klein, K. U.
    BRITISH JOURNAL OF ANAESTHESIA, 2017, 118 (03) : 400 - 406
  • [25] Transcranial doppler detection of circulating cerebral microemboli [Detektion zirkulierender cerebraler mikroemboli mittels transkranieller dopplersonographie]
    Reinecke H.
    Nabavi D.G.
    Allroggen A.
    Droste D.W.
    Breithardt G.
    Ringelstein E.B.
    Zeitschrift für Kardiologie, 2001, 90 (1): : 43 - 51
  • [26] Cerebral Artery Vasospasm Detection Using Transcranial Doppler Signal Analysis
    Elzaafarany, Khaled
    Aly, Moustafa H.
    Kumar, Gyanendra
    Nakhmani, Arie
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (08) : 2191 - 2202
  • [27] Transcranial Doppler sonography evaluation of anterior cerebral artery hypoplasia or aplasia
    Kwon, HM
    Lee, YS
    JOURNAL OF THE NEUROLOGICAL SCIENCES, 2005, 231 (1-2) : 67 - 70
  • [28] TRANSCRANIAL DOPPLER SONOGRAPHY IN THE CASE OF CEREBRAL ARTERIAL EMBOLISM
    SOLARO, M
    MANCINI, G
    SPALLONI, A
    ZANETTE, EM
    GIORNALE DI NEUROPSICOFARMACOLOGIA, 1995, 17 (05): : 125 - 128
  • [29] Cerebral microemboli detected by transcranial doppler in patients treated with extracorporeal membrane oxygenation
    Marinoni, M.
    Migliaccio, M. L.
    Trapani, S.
    Bonizzoli, M.
    Gucci, L.
    Cianchi, G.
    Gallerini, A.
    Buoninsegni, L. Tadini
    Cramaro, A.
    Valente, S.
    Chiostri, M.
    Peris, A.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2016, 60 (07) : 934 - 944
  • [30] INCIDENCE OF TRANSCRANIAL DOPPLER-DETECTED CEREBRAL MICROEMBOLI IN PATIENTS REFERRED FOR ECHOCARDIOGRAPHY
    TONG, DC
    BOLGER, A
    ALBERS, GW
    STROKE, 1994, 25 (11) : 2138 - 2141