Distal Chevron Osteotomy vs The Simple, Effective, Rapid, Inexpensive Technique (SERI) for Mild to Moderate Isolated Hallux Valgus: A Randomized Controlled Study

被引:3
|
作者
Palmanovich, Ezequiel [1 ]
Ohana, N. [1 ]
David, Segal [1 ]
Small, I [2 ]
Hetsroni, I [1 ]
Amar, E. [2 ]
Sharfman, Z. T. [3 ]
Segal, D. [1 ]
Atzmon, R. [4 ]
机构
[1] Sackler Fac Med, Meir Med Ctr, Dept Orthopaed Surg, Kefar Sava, Israel
[2] Tel Aviv Univ, Sackler Fac Med, Tel Aviv Med Ctr, Dept Orthopaed Surg, Tel Aviv, Israel
[3] Dept Orthopaed Surg Montefiore, Bronx, NY USA
[4] Ben Gurion Univ Negev, Fac Hlth & Sci, Assuta Med Ctr, Dept Orthopaed Surg, Ashdod, Israel
关键词
SERI; Chevron; Minimal invasive surgery; Hallux valgus; METATARSAL OSTEOTOMY;
D O I
10.1007/s43465-020-00209-0
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Hallux valgus is a common foot deformity that leads to functional disability with serious sequelae. Minimally invasive surgery is often used to treat hallux valgus in order to reduce wound complications and improve recovery time. The objective of this study was to compare a Simple, Effective, Rapid, Inexpensive (SERI) technique with a simple Chevron technique in patients with minimum of 1-year follow-up. Methods and Materials Between the years 2014-2015, we performed a prospective study comparing the SERI minimally invasive technique to treat symptomatic hallux valgus with a standard chevron osteotomy technique. All procedures were performed by a single fellowship trained foot and ankle surgeon. Twenty-one patients were randomized to the SERI cohort and 15 to the standard Chevron technique. Results The mean preoperative intermetatarsal angle (IMA) of the SERI group was 14.8 +/- 1.9 (11.9-22.9). The mean preoperative IMA of the Chevron control group was 13.3 +/- 2.3 (10.4-18.2) (p = 0.038). The mean IMA two weeks after the surgery was 6.0 +/- 2.3 (2.4-12) in the SERI group, and 6.1 +/- 3 (2.6-13.1) in the control group. At the two-week and 1-year follow-up, there was no significant difference found in the IMA between the two groups (p = 0.871). The mean hallux valgus angle reduction was 11.85 +/- 4.88 (3-20.8) and 11.09 +/- 6.51 (- 1.1 to 22.5) in the SERI and Chevron groups, respectively (p = 0.69). Neither groups reported symptomatic transfer metatarsalgia throughout the follow-up period. The SERI group had increased metatarsophalangeal joint (MTPJ) motion (p < 0.001); however, all other parameters with similar. Conclusion The SERI technique provided comparable outcomes at up to 1-year follow-up when compared with a standard Chevron osteotomy for moderate hallux valgus. This study demonstrated good reproducible results using the SERI technique for moderate hallux valgus. Trial Registration Approved by local IRB at MMC.
引用
收藏
页码:110 / 118
页数:9
相关论文
共 22 条
  • [21] Piezoelectric tools versus traditional oscillating saw for distal linear osteotomy in hallux valgus correction: Triple-blinded, randomized controlled study
    Mosca, Massimiliano
    Russo, Alessandro
    Caravelli, Silvio
    Massimi, Simone
    Vocale, Emanuele
    Grassi, Alberto
    Censoni, Davide
    Fuiano, Mario
    Zaffagnini, Stefano
    [J]. FOOT AND ANKLE SURGERY, 2022, 28 (03) : 300 - 306
  • [22] A comparison of proximal and distal Chevron osteotomy, both with lateral soft-tissue release, for moderate to severe hallux valgus in patients undergoing simultaneous bilateral correction A PROSPECTIVE RANDOMISED CONTROLLED TRIAL
    Lee, K. B.
    Cho, N. Y.
    Park, H. W.
    Seon, J. K.
    Lee, S. H.
    [J]. BONE & JOINT JOURNAL, 2015, 97B (02): : 202 - 207