Nasal nitric oxide: A comparison of measurement techniques

被引:50
|
作者
Silkoff, PE [1 ]
Chatkin, J [1 ]
Qian, W [1 ]
Chakravorty, S [1 ]
Gutierrez, C [1 ]
Furlott, H [1 ]
McClean, P [1 ]
Rai, S [1 ]
Zamel, N [1 ]
Haight, J [1 ]
机构
[1] Natl Jewish Med & Res Ctr, Denver, CO 80206 USA
来源
AMERICAN JOURNAL OF RHINOLOGY | 1999年 / 13卷 / 03期
关键词
D O I
10.2500/105065899781389803
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Nasal nitric oxide measurement may be a surrogate marker of upper airway inflammation. There is, however, no standardized measurement technique; and this led us to examine measurement techniques for acceptability and reproducibility In five subjects we examined the flow dependence of nasal NO. In 13 healthy volunteers, nasal NO was measured on-line by five methods: 1) Tidal nasal and oral breathing: NO sampling during exclusive nasal followed by exclusive oral tidal breathing; 2) Fixed flow exhalation: NO sampling during exclusive nasal followed by exclusive oral exhalation at 100 mL/second from total lung capacity, 3) Nasal-oral aspiration: air aspirated from the mouth via both nares at 100 mL/second with glottis closure; 4) Aspiration from one nares: air aspirated from one nares at 3.3 mL/second using nitric oxide analyzer sample line with velum closure; 5) Nasal Insufflation: NO sampled at one nares as air insufflated into the other nares at a flow of 100 mL/second with velum closure. Acceptability of all methods was assessed by subjects and technicians. Nasal NO concentration showed a significant inverse correlation with transnasal flow rate. All methods showed excellent reproducibility as assessed by the intraclass correlation coefficient except tidal breathing, which showed highly variable breath-to-breath NO levels, although mean breath values were reproducible. Mean nasal NO concentrations with methods 1, 2, 3, 4, and 5 were 32.1, 50.2, 62.8 1381, and 60.0 ppb, respectively. Velum closure was not always achieved in methods 4 and 5 whereas methods I and 2 required separate nasal and oral procedures. Method 5 had reduced acceptability. NO concentrations were similar with methods that used the same airflow (2, 3. and 5). Nasal NO can be sampled in different ways with excellent reproducibility. In view of the flow dependence of nasal NO, it is vital to use a constant flow rate, and lower airway NO contribution must be excluded or subtracted The fixed flow exhalation appears to be the preferred method as it is highly reproducible and acceptable.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 50 条
  • [21] Comparison of nasal nitric oxide in allergic versus nonallergic rhinitis
    Kavut, Baccioglu A.
    Gungor, O.
    Kalpaklioglu, F.
    ALLERGY, 2013, 68 : 185 - 185
  • [22] Sleep-disordered breathing children. Measurement of nasal nitric oxide and fractional exhaled nitric oxide
    Huang, Y.
    Zou, Y.
    Mai, F.
    Zhang, X.
    Liu, Y.
    Lin, X.
    HNO, 2016, 64 (03) : 169 - 174
  • [23] Measurement of nasal nitric oxide by hand-held and stationary devices
    Montella, Silvia
    Alving, Kjell
    Maniscalco, Mauro
    Sofia, Matteo
    De Stefano, Sara
    Raia, Valeria
    Santamaria, Francesca
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2011, 41 (10) : 1063 - 1070
  • [24] Clinical Application of Nasal Nitric Oxide Measurement in Pediatric Airway Diseases
    Manna, Angelo
    Montella, Silvia
    Maniscalco, Mauro
    Maglione, Marco
    Santamaria, Francesca
    PEDIATRIC PULMONOLOGY, 2015, 50 (01) : 85 - 99
  • [25] Nasal nitric oxide measurement variability to establish a standard for reliable results
    Beydon, Nicole
    ERJ OPEN RESEARCH, 2022, 8 (02)
  • [26] The value of nasal nitric oxide measurement in the diagnosis of primary ciliary dyskinesia
    Zhang Xiang
    Wang Xinglan
    Li Huimin
    Wang Wei
    Zhao Shunying
    儿科学研究(英文), 2019, 3 (04) : 209 - 210-211-212-213
  • [27] Nasal nitric oxide in children: A novel measurement technique and normal values
    Daya, H
    Qian, W
    McClean, P
    Haight, J
    Zamel, N
    Papsin, BC
    Forte, V
    LARYNGOSCOPE, 2002, 112 (10): : 1831 - 1835
  • [28] Nasal nitric oxide (NO) interferes measurement of exhaled NO during exercise.
    Ogawa, K
    Nakano, H
    Ide, H
    Imada, M
    Iwamoto, J
    FASEB JOURNAL, 1997, 11 (03): : 296 - 296
  • [29] Measurement of nasal nitric oxide: evaluation of six different sampling methods
    de Winter-de Groot, K. M.
    van der Ent, C. K.
    EUROPEAN JOURNAL OF CLINICAL INVESTIGATION, 2009, 39 (01) : 72 - 77
  • [30] The value of nasal nitric oxide measurement in the diagnosis of primary ciliary dyskinesia
    Zhang, Xiang
    Wang, Xinglan
    Li, Huimin
    Wang, Wei
    Zhao, Shunying
    PEDIATRIC INVESTIGATION, 2019, 3 (04) : 209 - 213