Nasal nitric oxide: A comparison of measurement techniques

被引:50
|
作者
Silkoff, PE [1 ]
Chatkin, J [1 ]
Qian, W [1 ]
Chakravorty, S [1 ]
Gutierrez, C [1 ]
Furlott, H [1 ]
McClean, P [1 ]
Rai, S [1 ]
Zamel, N [1 ]
Haight, J [1 ]
机构
[1] Natl Jewish Med & Res Ctr, Denver, CO 80206 USA
来源
AMERICAN JOURNAL OF RHINOLOGY | 1999年 / 13卷 / 03期
关键词
D O I
10.2500/105065899781389803
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Nasal nitric oxide measurement may be a surrogate marker of upper airway inflammation. There is, however, no standardized measurement technique; and this led us to examine measurement techniques for acceptability and reproducibility In five subjects we examined the flow dependence of nasal NO. In 13 healthy volunteers, nasal NO was measured on-line by five methods: 1) Tidal nasal and oral breathing: NO sampling during exclusive nasal followed by exclusive oral tidal breathing; 2) Fixed flow exhalation: NO sampling during exclusive nasal followed by exclusive oral exhalation at 100 mL/second from total lung capacity, 3) Nasal-oral aspiration: air aspirated from the mouth via both nares at 100 mL/second with glottis closure; 4) Aspiration from one nares: air aspirated from one nares at 3.3 mL/second using nitric oxide analyzer sample line with velum closure; 5) Nasal Insufflation: NO sampled at one nares as air insufflated into the other nares at a flow of 100 mL/second with velum closure. Acceptability of all methods was assessed by subjects and technicians. Nasal NO concentration showed a significant inverse correlation with transnasal flow rate. All methods showed excellent reproducibility as assessed by the intraclass correlation coefficient except tidal breathing, which showed highly variable breath-to-breath NO levels, although mean breath values were reproducible. Mean nasal NO concentrations with methods 1, 2, 3, 4, and 5 were 32.1, 50.2, 62.8 1381, and 60.0 ppb, respectively. Velum closure was not always achieved in methods 4 and 5 whereas methods I and 2 required separate nasal and oral procedures. Method 5 had reduced acceptability. NO concentrations were similar with methods that used the same airflow (2, 3. and 5). Nasal NO can be sampled in different ways with excellent reproducibility. In view of the flow dependence of nasal NO, it is vital to use a constant flow rate, and lower airway NO contribution must be excluded or subtracted The fixed flow exhalation appears to be the preferred method as it is highly reproducible and acceptable.
引用
收藏
页码:169 / 178
页数:10
相关论文
共 50 条
  • [1] A comparison of nasal nitric oxide measurement modes
    Deschamp, Ashley R.
    Schornick, Leah
    Clem, Charles
    Hazucha, Milan
    Shapiro, Adam J.
    Davis, Stephanie D.
    PEDIATRIC PULMONOLOGY, 2017, 52 (11) : 1381 - 1382
  • [2] Measurement of nasal nitric oxide
    Corbelli, Regula
    Hammer, Juerg
    PAEDIATRIC RESPIRATORY REVIEWS, 2007, 8 (03) : 269 - 272
  • [3] Unilateral nasal nitric oxide measurement after nasal surgery
    Qian, W
    Chatkin, JM
    Djupesland, PG
    McClean, P
    Zamel, N
    Irish, JC
    Haight, JSJ
    ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2000, 109 (10): : 952 - 957
  • [4] Measurement of nitric oxide in human nasal airway
    Imada, M
    Iwamoto, J
    Nonaka, S
    Kobayashi, Y
    Unno, T
    EUROPEAN RESPIRATORY JOURNAL, 1996, 9 (03) : 556 - 559
  • [5] NO way! Nasal nitric oxide measurement in infants
    Lucas, Jane S.
    Walker, Woolf T.
    EUROPEAN RESPIRATORY JOURNAL, 2018, 51 (06)
  • [6] Measurement Of Nasal and Exhaled Nitric Oxide In Chronic Rhinosinusitis and Its Comparison According To The Presence Of Nasal Polyps
    Bae, Woo Yong
    Jung, Jin-A.
    Nam, Young-Hee
    JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2014, 133 (02) : AB129 - AB129
  • [7] Advantages of unilateral nasal nitric oxide measurement vs bilateral measurement
    Qian, W
    Chatkin, JM
    Diupesland, PG
    McClean, P
    Zamel, N
    Irish, J
    Haight, J
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (03) : A865 - A865
  • [8] AN INTERCOMPARISON OF NITRIC-OXIDE MEASUREMENT TECHNIQUES
    HOELL, JM
    GREGORY, GL
    MCDOUGAL, DS
    CARROLL, MA
    MCFARLAND, M
    RIDLEY, BA
    DAVIS, DD
    BRADSHAW, J
    RODGERS, MO
    TORRES, AL
    JOURNAL OF GEOPHYSICAL RESEARCH-ATMOSPHERES, 1985, 90 (D7) : 2843 - 2851
  • [9] Exhaled and nasal nitric oxide measurement in the evaluation of chronic cough
    Maniscalco, Mauro
    Fuschillo, Salvatore
    Gaudiosi, Carlo
    De Felice, Alberto
    Martucci, Michele
    Motta, Andrea
    NITRIC OXIDE-BIOLOGY AND CHEMISTRY, 2019, 83 : 19 - 23
  • [10] Quantitative measurement of nasal production of nitric oxide in awake humans
    Jenkins, IR
    Langlois, D
    ANAESTHESIA AND INTENSIVE CARE, 1995, 23 (06) : 702 - 705