Theoretical Analysis of Resolution and Noise Properties of PET Image Reconstruction with and without Sinogram Blurring Modeling

被引:0
|
作者
Ahn, Sangtae [1 ]
机构
[1] GE Global Res, Niskayuna, NY 12309 USA
关键词
SPATIAL-RESOLUTION; MAXIMUM-LIKELIHOOD; TOMOGRAPHY;
D O I
暂无
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The detector response due to inter-crystal scatter, penetration and non-colinearity in PET can be modeled using blurring point spread functions (PSFs) in sinogram or image space. Incorporating PSFs into image reconstruction is expected to provide better image quality because of accurate system modeling. It has been widely observed that PSF-based reconstruction produces better spatial resolution with more pronounced overshoot/undershoot near edges and yields lower variance and more correlated image noise than non-PSF reconstruction. These findings have been mostly empirically made and there has not been much of rigorous explanation about the reason for the behaviors. In this study, we investigate the underlying mathematical structure of PSF-based and non-PSF image reconstruction and attempt to provide a mathematical explanation about the distinct behaviors they show. The local impulse response and the covariance of PSF-based and non-PSF penalized-likelihood image reconstruction are analyzed in continuous space to obtain useful insights. From the continuous-space analysis, we address why PSF-based reconstruction produces pronounced overshoot/undershoot near edges and what is the limitation of non-PSF reconstruction in achievable image resolution. In addition, it is analytically shown that PSF-based reconstruction results in spatially more correlated noise than non-PSF reconstruction at matched ensemble pixel variance. Finally, it is demonstrated that PSF-based reconstruction not only produces a lower pixel variance than non-PSF reconstruction at matched spatial resolution but also nearly achieves the minimum pixel variance for given spatial resolution.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Iterative reconstruction of Fourier-rebinned PET data using sinogram blurring function estimated from point source scans
    Tohme, Michel S.
    Qi, Jinyi
    MEDICAL PHYSICS, 2010, 37 (10) : 5530 - 5540
  • [22] SPATIAL RESOLUTION AND NOISE PROPERTIES OF REGULARIZED MOTION-COMPENSATED IMAGE RECONSTRUCTION
    Chun, Se Young
    Fessler, Jeffrey A.
    2009 IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: FROM NANO TO MACRO, VOLS 1 AND 2, 2009, : 863 - 866
  • [23] PET Image Reconstruction Incorporating 3D Mean-Median Sinogram Filtering
    Mokri, S. S.
    Saripan, M. I.
    Abd Rahni, A. A.
    Nordin, A. J.
    Hashim, S.
    Marhaban, M. H.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2016, 63 (01) : 157 - 169
  • [24] Scanner Dependent Noise Properties of the Q.Clear PET Image Reconstruction Tool
    Lantos, Judit
    Iagaru, Andrei
    Levin, Craig S.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [25] Influence of Iterative Reconstruction Algorithms on PET Image Resolution
    Karpetas, G. E.
    Michail, C. M.
    Fountos, G. P.
    Valais, I. G.
    Nikolopoulos, D.
    Kandarakis, I. S.
    Panayiotakis, G. S.
    INTERNATIONAL CONFERENCE ON BIO-MEDICAL INSTRUMENTATION AND RELATED ENGINEERING AND PHYSICAL SCIENCES (BIOMEP 2015), 2015, 637
  • [26] Neural Radiance Fields Enabled Continuous PET Image Modeling and High-Resolution Reconstruction
    Yang, Bao
    He, Pan
    Liu, Shenman
    Zhou, Linghong
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [27] NOISE AND RESOLUTION OF BAYESIAN RECONSTRUCTION FOR MULTIPLE IMAGE CONFIGURATIONS
    CHINN, G
    HUANG, SC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (06) : 2059 - 2063
  • [28] A direct sinogram-restoration method for fast image reconstruction in compact DOI-PET systems
    Kao, CM
    Chen, CT
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (01) : 208 - 214
  • [29] Statistical emission image reconstruction for randoms-precorrected PET scans using negative sinogram values
    Ahn, S
    Fessler, JA
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3062 - 3066
  • [30] Positron range modeling for statistical PET image reconstruction
    Bai, T
    Ruangma, A
    Laforest, R
    Tai, YC
    Leahy, RM
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2501 - 2505