Technical Note: Algebraic iterative image reconstruction using a cylindrical image grid for tetrahedron beam computed tomography

被引:1
|
作者
Kim, Joshua [1 ,2 ]
Ionascu, Dan [3 ]
Zhang, Tiezhi [2 ,3 ]
机构
[1] Oakland Univ, Dept Phys, Rochester, MI 48309 USA
[2] TetraImaging Inc, Troy, MI 48098 USA
[3] William Beaumont Hosp, Dept Radiat Oncol, Royal Oak, MI 48073 USA
关键词
CBCT; TBCT; image reconstruction; SART; TECHNIQUE SART; SYSTEM; ART;
D O I
10.1118/1.4812886
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To accelerate iterative algebraic reconstruction algorithms using a cylindrical image grid. Methods: Tetrahedron beam computed tomography (TBCT) is designed to overcome the scatter and detector problems of cone beam computed tomography (CBCT). Iterative algebraic reconstruction algorithms have been shown to mitigate approximate reconstruction artifacts that appear at large cone angles, but clinical implementation is limited by their high computational cost. In this study, a cylindrical voxelization method on a cylindrical grid is developed in order to take advantage of the symmetries of the cylindrical geometry. The cylindrical geometry is a natural fit for the circular scanning trajectory employed in volumetric CT methods such as CBCT and TBCT. This method was implemented in combination with the simultaneous algebraic reconstruction technique (SART). Both two- and three-dimensional numerical phantoms as well as a patient CT image were utilized to generate the projection sets used for reconstruction. The reconstructed images were compared to the original phantoms using a set of three figures of merit (FOM). Results: The cylindrical voxelization on a cylindrical reconstruction grid was successfully implemented in combination with the SART reconstruction algorithm. The FOM results showed that the cylindrical reconstructions were able to maintain the accuracy of the Cartesian reconstructions. In three dimensions, the cylindrical method provided better accuracy than the Cartesian methods. At the same time, the cylindrical method was able to provide a speedup factor of approximately 40 while also reducing the system matrix storage size by 2 orders of magnitude. Conclusions: TBCT image reconstruction using a cylindrical image grid was able to provide a significant improvement in the reconstruction time and a more compact system matrix for storage on the hard drive and in memory while maintaining the image quality provided by the Cartesian voxelization on a Cartesian grid. (C) 2013 American Association of Physicists in Medicine.
引用
收藏
页数:12
相关论文
共 50 条
  • [21] Novel iterative image reconstruction algorithm for electrical capacitance tomography: Directional algebraic reconstruction technique
    Kim, Ji Hoon
    Choi, Bong Yeol
    Kim, Kyung Youn
    IEICE TRANSACTIONS ON FUNDAMENTALS OF ELECTRONICS COMMUNICATIONS AND COMPUTER SCIENCES, 2006, E89A (06): : 1578 - 1584
  • [22] Tetrahedron Beam Computed Tomography: A New Design of Online Imaging System for Image Guided Radiotherapy
    Zhang, T.
    Schulze, D.
    MEDICAL PHYSICS, 2008, 35 (06)
  • [23] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Bittencourt, Marcio Sommer
    Schmidt, Bernhard
    Seltmann, Martin
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner Guenther
    Achenbach, Stephan
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (07): : 1081 - 1087
  • [24] Iterative reconstruction in image space (IRIS) in cardiac computed tomography: initial experience
    Márcio Sommer Bittencourt
    Bernhard Schmidt
    Martin Seltmann
    Gerd Muschiol
    Dieter Ropers
    Werner Günther Daniel
    Stephan Achenbach
    The International Journal of Cardiovascular Imaging, 2011, 27 : 1081 - 1087
  • [25] Dual source and dual detector arrays tetrahedron beam computed tomography for image guided radiotherapy
    Kim, Joshua
    Lu, Weiguo
    Zhang, Tiezhi
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (03): : 615 - 630
  • [26] Iterative Image Reconstruction Algorithm with Parameter Estimation by Neural Network for Computed Tomography
    Kojima, Takeshi
    Yoshinaga, Tetsuya
    ALGORITHMS, 2023, 16 (01)
  • [27] Radiation Dose Reduction in Computed Tomography: Implementation of an Iterative Image Reconstruction Method
    Chartrand-Lefebvre, Carl
    Prosmanne, Odile
    Belair, Manon
    Therasse, Eric
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2013, 64 (04): : 386 - 386
  • [28] Hardware Acceleration of Iterative Image Reconstruction for X-Ray Computed Tomography
    Kim, Jung Kuk
    Zhang, Zhengya
    Fessler, Jeffrey A.
    2011 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING, 2011, : 1697 - 1700
  • [29] Improved image quality of helical computed tomography of the head in children by iterative reconstruction
    Ono, Shun
    Niwa, Tetsu
    Yanagimachi, Noriharu
    Yamashita, Tomohiro
    Okazaki, Takashi
    Nomura, Takakiyo
    Hashimoto, Jun
    Imai, Yutaka
    JOURNAL OF NEURORADIOLOGY, 2016, 43 (01) : 31 - 36
  • [30] Tetrahedron Beam Computed Tomography (TBCT): A Novel Online Imaging System for Image Guided Radiotherapy
    Zhang, T.
    Xu, X.
    Schulze, D.
    Yan, D.
    Martinez, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 75 (03): : S636 - S637