Dosimetric benefits of intensity-modulated radiotherapy and volumetric-modulated arc therapy in the treatment of postoperative cervical cancer patients

被引:32
|
作者
Deng, Xia [1 ]
Han, Ce [1 ]
Chen, Shan [2 ]
Xie, Congying [1 ]
Yi, Jinling [1 ]
Zhou, Yongqiang [1 ]
Zheng, Xiaomin [1 ]
Deng, Zhenxiang [1 ]
Jin, Xiance [1 ]
机构
[1] Wenhzou Med Univ, Affiliated Hosp 1, Radiotherapy & Chemotherapy Dept, Wenzhou, Peoples R China
[2] Elekta Instrument Shanghai Ltd, Dept Clin Solut Support, Shanghai, Peoples R China
来源
基金
中国国家自然科学基金;
关键词
cervical cancer; intensity-modulated radiotherapy; volumetric-modulated arc therapy; whole pelvic conformal radiotherapy; WHOLE PELVIC RADIOTHERAPY; RADIATION-THERAPY; GYNECOLOGIC MALIGNANCIES; CONCURRENT CHEMOTHERAPY; IMRT; RISK; ENDOMETRIAL; INTERMEDIATE; CISPLATIN; BOWEL;
D O I
10.1002/acm2.12003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
As the advantage of using complex volumetric-modulated arc therapy (VMAT) in the treatment of gynecologic cancer has not yet been fully determined, the purpose of this study was to investigate the dosimetric advantages of VMAT by comparing directly with whole pelvic conformal radiotherapy (CRT) and intensity-modulated radiotherapy (IMRT) in the treatment of 15 postoperative cervical cancer patients. Four-field CRT, seven-field IMRT, and two-arc VMAT plans were generated for each patient with identical objective functions to achieve clinically acceptable dose distribution. Target coverage and OAR sparing differences were investigated through dose-volume histogram (DVH) analysis. Nondosimtric differences between IMRT and VMAT were also compared. Target coverage presented by V95% were 88.9% +/- 3.8%, 99.9% +/- 0.07%, and 99.9% +/- 0.1% for CRT, IMRT, and VMAT, respectively. Significant differences on conformal index (CI) and conformal number (CN) were observed with CIs of 0.37 +/- 0.07, 0.55 +/- 0.04, 0.61 +/- 0.04, and CNs of 0.33 +/- 0.06, 0.55 +/- 0.04, 0.60 +/- 0.04 for CRT, IMRT, and VMAT, respectively. IMRT and VMAT decreased the dose to bladder and rectum significantly compared with CRT. No significant differences on the Dmean, V45, and V30 of small bowel were observed among CRT, IMRT, and VMAT. However, VMAT (10.4 +/- 4.8 vs. 19.8 +/- 11.0, P = 0.004) and IMRT (12.3 +/- 5.0 vs. 19.8 +/- 11.0, P = 0.02) decreased V40, increased the Dmax of small bowel and the irradiation dose to femoral heads compared with CRT. VMAT irradiated less dose to bladder, rectum, small bowel and larger volume of health tissue with a lower dose (V5 and V10) compared with IMRT, although the differences were not statistical significant. In conclusion, VMAT and IMRT showed significant dosimetric advantages both on target coverage and OAR sparing compared with CRT in the treatment of postoperative cervical cancer. However, no significant difference between IMRT and VMAT was observed except for slightly better dose conformity, slightly less MU, and significant shorter delivery time achieved for VMAT.
引用
收藏
页码:25 / 31
页数:7
相关论文
共 50 条
  • [11] Outcomes of patients with anal cancer treated with volumetric-modulated arc therapy or intensity-modulated radiotherapy and concurrent chemotherapy
    Yucel, Serap
    Kadioglu, Huseyin
    Gural, Zeynep
    Akgun, Zuleyha
    Saglam, Esra Kaytan
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2021, 17 (01) : 51 - 55
  • [12] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Arc Therapy for Rectal Cancer
    Oskeroglu Kaplan, Sedenay
    Akboru, Halil
    Sarali, Yunus
    Altin, Suleyman
    Unsal, Mustafa
    TURK ONKOLOJI DERGISI-TURKISH JOURNAL OF ONCOLOGY, 2019, 34 (02): : 59 - 65
  • [13] Dosimetric Comparison to Organs at Risk Sparing Using Volumetric-Modulated Arc Therapy Versus Intensity-Modulated Radiotherapy in Postoperative Radiotherapy of Left-Sided Breast Cancer
    Qiao, L.
    Xie, J.
    Cheng, J.
    Liang, N.
    Deng, G.
    Zhang, J.
    Zhang, J.
    Luo, H.
    MEDICAL PHYSICS, 2015, 42 (06) : 3238 - 3238
  • [14] A Dosimetric Comparison of Volumetric-Modulated Arc Therapy to Intensity-Modulated Radiation Therapy in the Treatment of Locally Advanced Rectal Carcinoma
    Eldebawy E.
    Rashed Y.A.
    AlKhaldi M.
    Day E.
    Iranian Journal of Medical Physics, 2020, 17 (06) : 374 - 379
  • [15] Intensity-modulated radiotherapy or volumetric-modulated arc therapy in patients with head and neck cancer: Focus on salivary glands dosimetry
    Vallard, Alexis
    Guy, Jean-Baptiste
    Ndong, Sylvie Mengue
    Vial, Nicolas
    Rivoirard, Romain
    Auberdiac, Pierre
    Mery, Benoite
    Langrand-Escure, Julien
    Espenel, Sophie
    Moncharmont, Coralie
    Ben Mrad, Majed
    Diao, Peng
    Goyet, Dominique
    Magne, Nicolas
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2016, 38 (07): : 1028 - 1034
  • [16] Dosimetric comparison between step-shoot intensity-modulated radiotherapy and volumetric-modulated arc therapy for upper thoracic and cervical esophageal carcinoma
    Gao, Min
    Li, Qilin
    Ning, Zhonghua
    Gu, Wendong
    Huang, Jin
    Mu, Jinming
    Pei, Honglei
    MEDICAL DOSIMETRY, 2016, 41 (02) : 131 - 135
  • [17] A Dosimetric Study of Volumetric Arc Modulation with RapidArc Versus Intensity-modulated Radiotherapy in Cervical Cancer Patients
    Goswami, Brijesh
    Jain, Rakesh Kumar
    Yadav, Suresh
    Kumar, Sunil
    Oommen, Saji
    Manocha, Sapna
    Jadhav, Ganesh K.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2021, 15 (05)
  • [18] Dosimetric Comparison of Helical Tomotherapy, Volumetric-Modulated Arc Therapy, and Intensity-Modulated Proton Therapy for Angiosarcoma of the Scalp
    Mizuno, Tomoki
    Tomita, Natsuo
    Takaoka, Taiki
    Tomida, Masashi
    Fukuma, Hiroshi
    Tsuchiya, Takahiro
    Shibamoto, Yuta
    TECHNOLOGY IN CANCER RESEARCH & TREATMENT, 2021, 20
  • [19] Dosimetric analysis and comparison of volumetric-modulated arc therapy versus intensity-modulated radiation therapy for liver carcinoma
    Chiang, Bing-Hao
    Schnell, Erich
    Hibbitts, Kerry
    Herman, Terence
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (01) : 138 - 140
  • [20] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Lin, X.
    Sun, T.
    Yin, Y.
    Liu, T.
    Lu, J.
    MEDICAL PHYSICS, 2011, 38 (06) : 3683 - +