Calibration of ultrasonic techniques using full matrix capture data for industrial inspection

被引:5
|
作者
Weston, M. [1 ,2 ]
Nageswaran, C. [1 ]
Sutcliffe, M. [1 ]
Peyton, A. [2 ]
Davis, C. [2 ]
Mudge, P. [1 ]
Wallace, P. [1 ]
机构
[1] TWI NDT Validat Ctr Wales, Margam SA13 2EZ, Port Talbot, Wales
[2] Univ Manchester, Manchester M13 9PL, Lancs, England
基金
英国工程与自然科学研究理事会;
关键词
Ultrasonic; full matrix capture; sequential phased array; calibration; wedge; sensitivity; techniques; modelling; CIVA; volumetric amplitude correction; ARRAY;
D O I
10.1784/insi.2012.54.11.602
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Standards and codes that govern the inspection of industrial components require the techniques selected for use to be calibrated using well-established methods. For ultrasonic techniques making use of data collected using the full matrix capture method to be accepted for use in industry, the methods by which the inspection system are to be calibrated must be well defined. This paper outlines the essential components of an ultrasonic system used for the inspection of a standard butt weld and presents the methods for calibrating the system where the techniques are based on the full matrix capture data. The calibration methods are developed to be as generic as possible in order to be widely applicable to techniques using full matrix capture data.
引用
收藏
页码:602 / +
页数:5
相关论文
共 50 条
  • [31] Multi-Frequency Time-Reversal-Based Imaging for Ultrasonic Nondestructive Evaluation Using Full Matrix Capture
    Fan, Chengguang
    Pan, Mengchun
    Luo, Feilu
    Drinkwater, Bruce W.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2014, 61 (12) : 2067 - 2074
  • [32] Stud bolt corrosion inspection blind trials using ultrasonic techniques
    Lee, R. J.
    Collett, N. J.
    Burch, S. F.
    INSIGHT, 2012, 54 (06) : 327 - 330
  • [34] Experience of WER primary circuit inspection using advanced ultrasonic techniques
    MartinezOna, R
    Funes, A
    Fernandez, FJ
    NDE IN THE NUCLEAR AND PRESSURE VESSEL INDUSTRIES, 1997, : 473 - 476
  • [35] Ultrasonic inspection of composite hydrogen reservoirs using frequency diversity techniques
    Zellouf, D
    Goyette, J
    Massicotte, D
    Bose, TK
    ULTRASONICS, 2001, 39 (03) : 203 - 209
  • [36] On the possibility of a priori validation of ultrasonic inspection techniques without using specimens
    V. G. Shcherbinskii
    Russian Journal of Nondestructive Testing, 2012, 48 : 623 - 637
  • [37] Adaptive Ultrasonic Full Matrix Capture Process for the Global Imaging of Complex Components with Curved Surfaces
    Miao, Wensong
    Liu, Ne
    Huang, Jingqiang
    Lu, Minghui
    SENSORS, 2024, 24 (01)
  • [38] Phased array ultrasonic imaging using angle beam virtual source full matrix capture-total focusing method
    Sumana
    Kumar, Anish
    NDT & E INTERNATIONAL, 2020, 116 (116)
  • [39] Early detection of high temperature hydrogen attack using the ultrasonic full matrix capture and advanced post-processing methods
    Dupont-Marillia, Frederic
    Krynicki, Joseph W.
    Belanger, Pierre
    NDT & E INTERNATIONAL, 2022, 130
  • [40] VARIABLE SPLIT APERTURE PROCESSING OF FULL MATRIX CAPTURE PHASED ARRAY DATA
    Long, R.
    Cawley, P.
    Russell, J.
    REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION, VOLS 30A AND 30B, 2011, 1335 : 819 - 826