Optimization of PV/Wind/Battery stand-alone system, using hybrid FPA/SA algorithm and CFD simulation, case study: Tehran

被引:78
|
作者
Tahani, Mojtaba [1 ]
Babayan, Narek [1 ]
Pouyaei, Arman [1 ]
机构
[1] Univ Tehran, Fac New Sci & Technol, Tehran, Iran
关键词
Hybrid system; Hybrid algorithm; Optimization; CFD; LPSP; GLOBAL SOLAR-RADIATION; WIND PRESSURES; HEAT-PUMP; MODELS; TURBINES; DESIGN; SHAPE; FLOW;
D O I
10.1016/j.enconman.2015.10.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
Renewable energy hybrid systems are a promising technology toward sustainable and clean development. Due to stochastic behavior of renewable energy sources, optimization of their convertors has great importance for increasing system's reliability and efficiency and also in order to decrease the costs. In this research study, it was aimed to study the utilization of an optimized hybrid PV/Wind/Battery system for a three story building, with an inclined surface on the edge of its roof, located in Tehran, capital of Iran. For this purpose, a new evolutionary based optimization technique, namely hybrid FPA/SA algorithm was developed, in order to maximize system's reliability and minimize system's costs. The new algorithm combines the approaches which are utilized in Flower Pollination Algorithm (FPA) and Simulated Annealing (SA) algorithm. The developed algorithm was validated using popular benchmark functions. Moreover the influence of PV panels tilt angle (which is equal to the slope of inclined part of the roof) is studied on the wind speed by using computational fluid dynamics (CFD) simulation. The outputs of CFD simulations are utilized as inputs for modeling wind turbine performance. The Loss of Power Supply Probability (LPSP) and Payback time are considered as objective functions, and PV panel tilt angle, number of PV panels and number of batteries are selected as decision variables. The results showed that if the tilt angle for PV panels is set equal to 30 and the number of PV panels is selected equal to 11 the fastest payback time which is 12 years and two months and maximum cumulative savings with LPSP equal to 3.28% will occur. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:644 / 659
页数:16
相关论文
共 50 条
  • [21] Stand-Alone Hybrid Renewable Energy System Simulation and Optimization Using Imperialist Competitive Algorithm
    Mirbagheri, S. Mina
    Mirbagheri, S. Zahra
    Mokhlis, Hazlie
    2014 INTERNATIONAL CONFERENCE ON POWER SYSTEM TECHNOLOGY (POWERCON), 2014, : 1127 - 1134
  • [22] OPTIMIZATION AND MODELING OF A STAND-ALONE WIND/PV HYBRD ENERGY SYSTEM
    El Badawe, Mohamed
    Iqbal, Tariq
    Mann, George K. I.
    2012 25TH IEEE CANADIAN CONFERENCE ON ELECTRICAL & COMPUTER ENGINEERING (CCECE), 2012,
  • [23] Performance evaluation of metaheuristic techniques for optimal sizing of a stand-alone hybrid PV/wind/battery system
    Fares, Dalila
    Fathi, Mohamed
    Mekhilef, Saad
    APPLIED ENERGY, 2022, 305
  • [24] Optimal Power Management Controller for a Stand-alone Solar PV/Wind/Battery Hybrid Energy System
    Kumaravel, S.
    Ashok, S.
    ENERGY SOURCES PART A-RECOVERY UTILIZATION AND ENVIRONMENTAL EFFECTS, 2015, 37 (04) : 407 - 415
  • [25] Optimal Design of Stand-Alone PV/Wind Generator and Diesel System by Using Individual Particle Optimization Algorithm
    Ahmari-Nezhad, A.
    Abbaspour-Tehrani-Fard, A.
    Ehsan, M.
    Fotuhi-Firuzabad, M.
    Abroshan, M.
    INTERNATIONAL REVIEW OF ELECTRICAL ENGINEERING-IREE, 2012, 7 (05): : 5474 - 5486
  • [26] A Type-1 fuzzy logic algorithm to manage the flow of energy in a stand-alone PV/Wind/Battery hybrid system
    Faquir, Sanaa
    Yahyaouy, Ali
    Tairi, Hamid
    Sabor, Jalal
    2015 INTELLIGENT SYSTEMS AND COMPUTER VISION (ISCV), 2015,
  • [27] Power control and simulation of a building integrated stand-alone hybrid PV-wind-battery system in Kasuga City, Japan
    Shaqour, Ayas
    Farzaneh, Hooman
    Yoshida, Yuichiro
    Hinokuma, Tatsuya
    ENERGY REPORTS, 2020, 6 : 1528 - 1544
  • [28] Size optimization of a stand-alone solar-wind-battery hybrid system for net zero energy buildings: A case study
    Sadeghibakhtiar, Elaheh
    Naeimi, Afshin
    Naderi, Shayan
    Pignatta, Gloria
    Behbahaninia, Ali
    ENERGY AND BUILDINGS, 2024, 313
  • [29] Control System Simulation for Stand-Alone Hybrid Wind Diesel System
    Rajasekaran, Vigneshwaran
    Merabet, Adel
    Ibrahim, Hussein
    Beguenane, Rachid
    Thongam, Jogendra S.
    2013 IEEE ELECTRICAL POWER & ENERGY CONFERENCE (EPEC), 2013,
  • [30] Multi-Objective Optimization of a Stand-alone Hybrid PV/wind/battery/diesel Micro-grid
    Omar, Ahmed Shaban
    Mohamed, Al-Attar Ali
    Senjyu, Tomonobu
    Hemeida, A. M.
    2019 IEEE CONFERENCE ON POWER ELECTRONICS AND RENEWABLE ENERGY (IEEE CPERE), 2019, : 391 - 396