Biomechanical comparison of two stabilization techniques for unstable sacral fractures

被引:23
|
作者
Bodzay, Tamas [1 ]
Szita, Janos [1 ]
Mano, Sandor [2 ,3 ]
Kiss, Laszlo [3 ]
Jonas, Zoltan [3 ]
Frenyo, Sandor [1 ]
Csernatony, Zoltan [2 ,3 ]
机构
[1] Peterfy Hosp, Ctr Trauma, H-1081 Budapest, Hungary
[2] Univ Debrecen, Lab Biomech, H-4012 Debrecen, Hungary
[3] Univ Debrecen, Dept Orthopaed, Med & Hlth Sci Ctr, H-4012 Debrecen, Hungary
关键词
FIXATION;
D O I
10.1007/s00776-012-0246-4
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of the study was to assess the stability provided by an ilio-iliac dorsal plate fixation technique using an AO narrow DCP on the pelvic brim in vertically and rotationally unstable type-C pelvic ring injuries. We examined 12 fresh cadaver pelvises in a single limb stance load. A type-C pelvic ring injury (a type I lateral sacral fracture in the classification of Denis with symphysis pubis rupture) was performed on the cadaver specimen and fixed with a four-hole narrow dynamic compression plate to stabilize the symphysis pubis rupture; the sacrum fracture was stabilized either anteriorly with two 3-hole reconstruction plates ("anterior plate osteosynthesis") or with a posterior fixation using a 12-hole narrow DCP. A cyclic load of between 100 and 250 N was applied to the fifth lumbar vertebra of the specimen. An extensometer was attached to both sides of the sacrum fracture to detect movements at the fracture site. We were able to achieve usable measurements in nine specimens. Three measurements were performed on each specimen, and the movements recorded at the fracture gap in trans-sacral plate fixation were higher than or similar to those observed for anterior plate synthesis in 23 out of 27 cases. Dorsal ilio-iliac bridge plate fixation provides somewhat reduced stability compared to anterior plate fixation, but the difference is not significant.
引用
收藏
页码:574 / 579
页数:6
相关论文
共 50 条
  • [21] Biomechanical comparison of four triangular osteosynthesis fixations for unilateral vertical sacral fractures
    Ma, Yupeng
    Zhao, Yong
    Hong, Huanyu
    Huang, Tao
    Li, Yu
    SCIENTIFIC REPORTS, 2023, 13 (01)
  • [22] Minimally invasive stabilization of sacral fractures
    Decker, S.
    Krettek, C.
    Stuebig, T.
    UNFALLCHIRURG, 2020, 123 (10): : 774 - 782
  • [23] The locking attachment plate for proximal fixation of periprosthetic femur fractures—a biomechanical comparison of two techniques
    Mark Lenz
    Markus Windolf
    Thomas Mückley
    Gunther O. Hofmann
    Michael Wagner
    Robert G. Richards
    Karsten Schwieger
    Boyko Gueorguiev
    International Orthopaedics, 2012, 36 : 1915 - 1921
  • [24] Biomechanical Comparison of 4 Fixation Techniques of Sacral Pedicle Screw in Osteoporotic Condition
    Yu, Bin-Sheng
    Zhuang, Xin-Ming
    Zheng, Zhao-Min
    Zhang, Jia-Fang
    Li, Ze-Min
    Lu, William W.
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (06): : 404 - 409
  • [25] Fixation of Greater Tuberosity Fractures A Biomechanical Comparison of Three Techniques
    Ishak, Charbel
    Sahajpal, Deenesh
    Chiang, Alexis
    Atallah, William
    Kummer, Frederick
    Jazrawi, Laith M.
    BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2006, 63 (3-4): : 98 - 99
  • [26] BIOMECHANICAL COMPARISON OF TRANS-SACRAL AND TRIANGULAR OSTEOSYNTHESIS IN A VERTICALLY UNSTABLE PELVIC FRACTURE MODEL
    Zamorano, David P.
    Min, Kyong S.
    Wahba, George
    Garcia, Ivan
    Bahtia, Nitin N.
    Lee, Thay Q.
    PROCEEDINGS OF THE 4TH FRONTIERS IN BIOMEDICAL DEVICES CONFERENCE AND EXPOSITION - 2009, 2009, : 105 - 106
  • [27] Transverse fractures of the olecranon: a biomechanical comparison of three fixation techniques
    Sadri, Hassan
    Stern, Richard
    Singh, Michael
    Linke, Berend
    Hoffmeyer, Pierre
    Schwieger, Karsten
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2011, 131 (01) : 131 - 138
  • [28] Transverse fractures of the olecranon: a biomechanical comparison of three fixation techniques
    Hassan Sadri
    Richard Stern
    Michael Singh
    Berend Linke
    Pierre Hoffmeyer
    Karsten Schwieger
    Archives of Orthopaedic and Trauma Surgery, 2011, 131 : 131 - 138
  • [29] Biomechanical comparison between two shotputting techniques
    Hilby, Darcy L.
    Bates, Barry T.
    Journal of Biomechanics, 1989, 22 (10)
  • [30] A biomechanical comparison of multidirectional nail and locking plate fixation in unstable olecranon fractures
    Argintar, Evan
    Martin, Benjamin D.
    Singer, Andrea
    Hsieh, Adam H.
    Edwards, Scott