Small Animal Optical Multispectral Cerenkov Tomography

被引:0
|
作者
Spinelli, Antonello E. [1 ]
Kuo, Chaincy [2 ]
Rice, Brad W. [2 ]
Calandrino, Riccardo [1 ]
Marzola, Pasquina [3 ]
Sbarbati, Andrea [3 ]
Boschi, Federico [3 ]
机构
[1] Ist Sci San Raffaele, Dept Med Phys, Via Olgettina 60, I-20132 Milan, Italy
[2] PerkinElmer Co, Alameda, CA 94501 USA
[3] Univ Verona, Dept Morphol Biomed Sci, Sect Anat & Histol, I-37100 Verona, Italy
关键词
LUMINESCENCE TOMOGRAPHY;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A novel pre-clinical imaging modality called Cerenkov luminescence imaging (CLI) has been recently introduced for small animals in vivo imaging. CLI is based on the detection of optical Cerenkov radiation generated by beta particles as they travel into the animal tissues with energy greater than Cerenkov threshold. The main goal of this work is the development of a novel optical image reconstruction method called multi spectral Cerenkov luminescence tomography (msCLT). The starting point of the msCLT reconstruction scheme is a set of 2D planar images acquired using several narrow bandpass filters. Because of the different tissues absorption at different wavelengths this provide distinctive information content that can be used for image reconstruction. More precisely the msCLT algorithm is based on a regularized iterative non-negative scheme in order to find the unknown source intensity solution, the theoretical Cerenkov emission spectrum was also included in the algorithm. In order to investigate the performances of the msCLT approach in vitro and in vivo imaging using (32)p-ATP were performed by using the IVIS 200 (Caliper, a PerkinElmer company). A set of spatial resolution measurements were performed using a small capillary source placed between several slices of chicken breast at different depths. The spatial resolution obtained from the msCLT reconstructed images of the capillary showed that the FWHM is 1.5 mm for a source placed at 6 mm depth. In order to investigate the in vivo performances of the msCLT reconstruction method, a control nude mice injected with 10 MBq of 32P-ATP were imaged. Whole body MRI was acquired to provide an anatomical localization of the Cerenkov emission. msCLT reconstructed images co-registered with MRI images showed that the Cerenkov emission regions matches well with anatomical regions, such as the brain, heart and abdomen. These results were also confirmed by ex vivo imaging of organs such as intestine, brain, heart and ribs.
引用
收藏
页码:4462 / 4466
页数:5
相关论文
共 50 条
  • [41] Optimizing in vivo small animal Cerenkov luminescence imaging (vol 17, 040506, 2012)
    Spinelli, Antonello E.
    Boschi, Federico
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (05)
  • [42] Persistent luminescence tomography for small animal imaging
    Cao, Xu
    Gong, Yuzhu
    Li, Yang
    Zhu, Shouping
    Zhang, Xuanxuan
    Zhan, Yonghua
    Kang, Fei
    Wang, Jing
    Liang, Jimin
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (03): : 1466 - 1476
  • [43] COMPUTER-TOMOGRAPHY IN SMALL ANIMAL NEUROLOGY
    LANG, J
    HUBER, P
    VANDEVELDE, M
    SCHWEIZER ARCHIV FUR TIERHEILKUNDE, 1988, 130 (04): : 167 - 183
  • [44] A three-dimensional multispectral fluorescence optical tomography imaging system for small animals based on a conical mirror design
    Li, Changqing
    Mitchell, Gregory S.
    Dutta, Joyita
    Ahn, Sangtae
    Leahy, Richard M.
    Cherry, Simon R.
    OPTICS EXPRESS, 2009, 17 (09): : 7571 - 7585
  • [45] Optical calibration protocol for an x-ray and optical multimodality tomography system dedicated to small-animal examination
    Da Silva, Anabela
    Leabad, Mehdi
    Driol, Clemence
    Bordy, Thomas
    Debourdeau, Mathieu
    Dinten, Jean-Marc
    Peltie, Philippe
    Rizo, Philippe
    APPLIED OPTICS, 2009, 48 (10) : D151 - D162
  • [46] Multispectral photoacoustic tomography for detection of small tumors inside biological tissues
    Hirasawa, Takeshi
    Okawa, Shinpei
    Tsujita, Kazuhiro
    Kushibiki, Toshihiro
    Fujita, Masanori
    Urano, Yasuteru
    Ishihara, Miya
    PHOTONS PLUS ULTRASOUND: IMAGING AND SENSING 2018, 2018, 10494
  • [47] Multispectral analysis of unstained human tissue using optical projection tomography
    Wedden, Sarah
    Mitchell, Lisa
    Boyd, Graeme
    Sharpe, James
    Robertson, Katherine
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2006, 126 (04) : 633 - 634
  • [48] Chromophore decomposition in multispectral time-resolved diffuse optical tomography
    Zouaoui, Judy
    Di Sieno, Laura
    Herve, Lionel
    Pifferi, Antonio
    Farina, Andrea
    Dalla Mora, Alberto
    Derouard, Jacques
    Dinten, Jean-Marc
    BIOMEDICAL OPTICS EXPRESS, 2017, 8 (10): : 4772 - 4787
  • [49] Small-animal optical imaging
    Ntziachristos, Vasilis
    Culver, Joseph P.
    Rice, Bradley W.
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)
  • [50] Multispectral guided fluorescence diffuse optical tomography using upconverting nanoparticles
    Svenmarker, Pontus
    Xu, Can T.
    Liu, Haichun
    Wu, Xia
    Andersson-Engels, Stefan
    APPLIED PHYSICS LETTERS, 2014, 104 (07)