Assessment of shoulder position variation and its impact on IMRT and VMAT doses for head and neck cancer

被引:26
|
作者
Neubauer, Emily [1 ]
Dong, Lei [1 ]
Followill, David S. [1 ]
Garden, Adam S. [2 ]
Court, Laurence E. [1 ]
White, R. Allen [3 ]
Kry, Stephen F. [1 ]
机构
[1] Univ Texas MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
[2] Univ Texas MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas MD Anderson Canc Ctr, Dept Bioinformat & Computat Biol, Houston, TX 77030 USA
来源
RADIATION ONCOLOGY | 2012年 / 7卷
关键词
Head and Neck; shoulder shifts; IMRT; VMAT; setup; shoulder; MODULATED ARC THERAPY; RADIOTHERAPY;
D O I
10.1186/1748-717X-7-19
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: For radiotherapy of the head and neck, 5-point mask immobilization is used to stabilize the shoulders. Still, the daily position of the shoulders during treatment may be different from the position in the treatment plan despite correct isocenter setup. The purpose of this study was to determine the interfractional displacement of the shoulders relative to isocenter over the course of treatment and the associated dosimetric effect of this displacement. Methods: The extent of shoulder displacements relative to isocenter was assessed for 10 patients in 5-point thermoplastic masks using image registration and daily CT-on-rails scans. Dosimetric effects on IMRT and VMAT plans were evaluated in Pinnacle based on simulation CTs modified to represent shoulder shifts between 3 and 15 mm in the superior-inferior, anterior-posterior, and right-left directions. The impact of clinically observed shoulder shifts on the low-neck dose distributions was examined. Results: Shoulder motion was 2-5 mm in each direction on average but reached 20 mm. Superior shifts resulted in coverage loss, whereas inferior shifts increased the dose to the brachial plexus. These findings were generally consistent for both IMRT and VMAT plans. Over a course of observed shifts, the dose to 99% of the CTV decreased by up to 101 cGy, and the brachial plexus dose increased by up to 72 cGy. Conclusions: he position of the shoulder affects target coverage and critical structure dose, and may therefore be a concern during the setup of head and neck patients, particularly those with low neck primary disease.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Variation of Neck Position With Image-guided Radiotherapy For Head And Neck Cancer
    Ove, Roger
    Cavalieri, Ronaldo
    Noble, Darin
    Russo, Suzanne M.
    AMERICAN JOURNAL OF CLINICAL ONCOLOGY-CANCER CLINICAL TRIALS, 2012, 35 (01): : 1 - 5
  • [32] IMRT/VMAT-SIB technique chemoradiation in locally advanced head and neck cancer: toxicity results
    Deodato, F.
    Cilla, S.
    Macchia, G.
    Grifa, F.
    Torre, G.
    Nuzzo, M.
    Mattiucci, G. C.
    Sallustio, G.
    Di Lullo, L.
    Micciche, F.
    Tagliaferri, L.
    Monari, F.
    Ntreta, M.
    Parmeggiani, C.
    Cortesi, A.
    Farioli, A.
    Cammelli, S.
    Frezza, G.
    Valentini, V.
    Morganti, A. G.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S501 - S502
  • [33] 3D conformal, IMRT and VMAT for the treatment of head and neck cancer: a brief literature review
    Afrin, Kazi T. T.
    Ahmad, Salahuddin
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2022, 21 (02) : 259 - 262
  • [34] Evaluation of IMRT and VMAT for Head-and-Neck Cancer With Flattening Filter-free (FFF) Beams
    Wu, Q.
    Yoo, S.
    Das, S.
    Yin, F.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2012, 84 (03): : S863 - S863
  • [35] Automated plan quality assessment tool for head and neck cancer VMAT plans
    van Bruggen, I.
    de Ronde, E.
    Steenbakkers, R.
    van den Hoek, A.
    van Zon-Meijer, T.
    Oldehinkel, E.
    Langendijk, J.
    Kierkels, R.
    Both, S.
    Korevaar, E.
    RADIOTHERAPY AND ONCOLOGY, 2021, 161 : S1427 - S1428
  • [36] Daily CBCT Reveals Shoulder Movement and Its Dosimetric Effects During Head and Neck IMRT
    Liu, C.
    Siddiqui, F.
    Chetty, I.
    Mao, W.
    MEDICAL PHYSICS, 2017, 44 (06) : 3052 - 3052
  • [37] Acute Radiation Dermatitis in Head and Neck Patients Treated With VMAT Versus IMRT
    Sapir, E.
    Bredfeldt, J.
    Schipper, M.
    Masi, K.
    Matuszak, M. M.
    Eisbruch, A.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E617 - E617
  • [38] Verification of patient position by daily electronic portal imaging in patients with head and neck cancer treated with imrt verification of patient position by daily electronic portal imaging in patients with head and neck cancer treated with IMRT
    Pehlivan, B.
    Bourhis, J.
    Pichenot, C.
    Auperin, A.
    Lefkopolous, D.
    Arriagada, R.
    RADIOTHERAPY AND ONCOLOGY, 2006, 81 : S355 - S356
  • [39] Evaluation of shoulder disability questionnaires used for the assessment of shoulder disability after neck dissection for head and neck cancer
    Goldstein, David P.
    Ringash, Jolie
    Bissada, Eric
    Jaquet, Yves
    Irish, Jonathan
    Chepeha, Douglas
    Davis, Aileen M.
    HEAD AND NECK-JOURNAL FOR THE SCIENCES AND SPECIALTIES OF THE HEAD AND NECK, 2014, 36 (10): : 1453 - 1458
  • [40] Constant dose rate VMAT and step-and-shoot IMRT in head and neck cancer: a comparative plan analysis
    Didona, A.
    Zucchetti, C.
    Dipilato, A. C.
    Iacco, M.
    Panizza, M. B.
    Frattegiani, A.
    Bini, V.
    Aristei, C.
    Tarducci, R.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S790 - S791