关键词
Dual mobility; Total hip arthroplasty; Retrieval; Wear; Long-term; FOLLOW-UP; ARTHROPLASTY; PROSTHESIS; DISLOCATION; SOCKET;
D O I
10.1007/s00264-017-3525-z
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Dual mobility THA implantations are increasing. THA survival of more than 15 years is considered long-term survival based on the Charnley prosthesis, which has a median wear rate of 39 to 98 mm(3)/year. What is the median wear rate of dual mobility THA cups and its repartition on the liner volume? What are the factors influencing dual mobility wear? Methods Thirty-five explants were analysed. The liners were entirely mapped with a fully automatic stripe light scanner that uses green LED light. Results The liners had a median wear rate of 38 mm(3)/year. The distribution of the wear between the two bearings varied greatly. No factor was found influencing wear volumes. Conclusions The median annual wear of dual mobility liners is at least as low as the wear of cemented polyethylene liners and lower than equivalent cementless liners. The two articulations of the dual mobility THA do not cause more wear.
引用
下载
收藏
页码:41 / 47
页数:7
相关论文
共 50 条
  • [41] The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation
    Nam Hoon Moon
    Min Uk Do
    Jung Shin Kim
    Jae Seung Seo
    Won Chul Shin
    Scientific Reports, 12
  • [42] Low Rate of Dislocation of Dual-mobility Cups in Primary Total Hip Arthroplasty
    Combes, Antoine
    Migaud, Henri
    Girard, Julien
    Duhamel, Alain
    Fessy, Michel Henri
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2013, 471 (12) : 3891 - 3900
  • [43] The usefulness of dual mobility cups in primary total hip arthroplasty patients at a risk of dislocation
    Moon, Nam Hoon
    Do, Min Uk
    Kim, Jung Shin
    Seo, Jae Seung
    Shin, Won Chul
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [44] Long-Term Results of the CLS Acetabular Cup in Primary Total Hip Replacement
    Rozkydal, Z.
    Janicek, P.
    Tomas, T.
    Florian, Z.
    ACTA CHIRURGIAE ORTHOPAEDICAE ET TRAUMATOLOGIAE CECHOSLOVACA, 2009, 76 (02) : 90 - 97
  • [45] Long-Term Effectiveness of Total Hip Replacement with the Collum Femoris Preserving Prosthesis
    You, Rui-jin
    Zheng, Wen-zhong
    Chen, Kun
    Lv, Hong-sheng
    Huang, Dian-feng
    Xiao, Yi-zeng
    Yang, De-yu
    Su, Zhai-quan
    CELL BIOCHEMISTRY AND BIOPHYSICS, 2015, 72 (01) : 43 - 47
  • [46] LONG-TERM RESULTS OF TOTAL HIP-REPLACEMENT IN ANKYLOSING-SPONDYLITIS
    BALDURSSON, H
    BRATTSTROM, H
    OLSSON, TH
    ACTA ORTHOPAEDICA SCANDINAVICA, 1987, 58 (03): : 305 - 305
  • [47] Wear of dual-mobility cups: a review article
    Di Laura, Anna
    Hothi, Harry
    Battisti, Clement
    Cerquiglini, Arianna
    Henckel, Johann
    Skinner, John
    Hart, Alister
    INTERNATIONAL ORTHOPAEDICS, 2017, 41 (03) : 625 - 633
  • [48] Long-term implant fixation and stress-shielding in total hip replacement
    Sumner, D. R.
    JOURNAL OF BIOMECHANICS, 2015, 48 (05) : 797 - 800
  • [49] Long-Term Effectiveness of Total Hip Replacement with the Collum Femoris Preserving Prosthesis
    Rui-jin You
    Wen-zhong Zheng
    Kun Chen
    Hong-sheng Lv
    Dian-feng Huang
    Yi-zeng Xiao
    De-yu Yang
    Zhai-quan Su
    Cell Biochemistry and Biophysics, 2015, 72 : 43 - 47
  • [50] Wear of dual-mobility cups: a review article
    Anna Di Laura
    Harry Hothi
    Clement Battisti
    Arianna Cerquiglini
    Johann Henckel
    John Skinner
    Alister Hart
    International Orthopaedics, 2017, 41 : 625 - 633