Critical load of slender elastomeric seismic isolators: An experimental perspective

被引:33
|
作者
Cardone, Donatello [1 ]
Perrone, Giuseppe [1 ]
机构
[1] Univ Basilicata, DiSGG, I-85100 Potenza, Italy
关键词
Seismic isolation; Elastomeric bearings; Critical load; Shear strain; Buckling; ISOLATION BEARINGS; STABILITY;
D O I
10.1016/j.engstruct.2012.02.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the most important aspects of the seismic response of elastomeric isolators is their stability under large shear strains. The bearing capacity of elastomeric isolators, indeed, progressively degrades while increasing horizontal displacement. This may greatly influence the design of elastomeric isolators, especially in high seismicity regions, where slender elastomeric isolators subjected to large horizontal displacements are a common practice. In the current design approach the critical load is evaluated based on the Haringx theory, modified to account for large shear strains by approximate correction factors. In this paper the critical behavior of a pair of slender elastomeric devices is experimentally evaluated at different strain amplitudes, ranging from approximately 50% to 150%. The experimental results are then compared to the predictions of a number of semi-empirical and theoretical formulations. The main conclusion of this study is that current design approaches are overly conservative for slender elastomeric seismic isolators, since they underestimate their critical load capacity at moderate-to-large shear strain amplitudes. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [21] Seismic Isolation of a Shear Wall Structure Using Rectangular Fiber-Reinforced Elastomeric Isolators
    Osgooei, Peyman M.
    Tait, Michael J.
    Konstantinidis, Dimitrios
    JOURNAL OF STRUCTURAL ENGINEERING, 2016, 142 (02)
  • [22] Experimental determination of the natural vibration frequency of elastomeric vibration isolators used in shipbuilding
    Titova, Yuliyana F.
    Yakovlev, Stanislav N.
    Polyakhov, Dmitry N.
    Krakhmaleva, Olga A.
    Andreev, Aleksandr N.
    MARINE INTELLECTUAL TECHNOLOGIES, 2024, (03):
  • [23] Experimental fire response of seismic elastomeric bearings
    Lucon, Massimiliano
    Baragatti, Paolo
    Possidente, Luca
    Tondini, Nicola
    ENGINEERING STRUCTURES, 2022, 254
  • [24] International investigation of shear displacement capacity of various elastomeric seismic-protection isolators for buildings
    Toshio Nishi
    Shigenobu Suzuki
    Masami Aoki
    Takeshi Sawada
    Shigeo Fukuda
    Journal of Rubber Research, 2019, 22 : 33 - 41
  • [25] Experimental assessment of utilizing fiber reinforced elastomeric isolators as bearings for bridge applications
    Al-Anany, Yasser M.
    Tait, Michael J.
    COMPOSITES PART B-ENGINEERING, 2017, 114 : 373 - 385
  • [26] International investigation of shear displacement capacity of various elastomeric seismic-protection isolators for buildings
    Nishi, Toshio
    Suzuki, Shigenobu
    Aoki, Masami
    Sawada, Takeshi
    Fukuda, Shigeo
    JOURNAL OF RUBBER RESEARCH, 2019, 22 (01) : 33 - 41
  • [27] Assessment of low temperature exposure for design and evaluation of elastomeric bridge bearings and seismic isolators in Canada
    Guay, Louis-Pierick
    Bouaanani, Najib
    CANADIAN JOURNAL OF CIVIL ENGINEERING, 2016, 43 (09) : 851 - 863
  • [28] Stretch-Stress Behavior of Elastomeric Seismic Isolators with Different Rubber Materials: Numerical Insight
    Milani, G.
    Milani, F.
    JOURNAL OF ENGINEERING MECHANICS-ASCE, 2012, 138 (05): : 416 - 429
  • [29] Simplified Approximations for Critical Design Parameters of Rectangular Fiber-Reinforced Elastomeric Isolators
    Van Engelen, Niel C.
    Konstantinidis, Dimitrios
    Tait, Michael J.
    JOURNAL OF ENGINEERING MECHANICS, 2017, 143 (08)
  • [30] Assessment of Seismic Load Capacity of a Slender Masonry Clock Tower
    Sozen, Sahin
    PERIODICA POLYTECHNICA-CIVIL ENGINEERING, 2022, 66 (02): : 491 - 501