Critical load of slender elastomeric seismic isolators: An experimental perspective

被引:33
|
作者
Cardone, Donatello [1 ]
Perrone, Giuseppe [1 ]
机构
[1] Univ Basilicata, DiSGG, I-85100 Potenza, Italy
关键词
Seismic isolation; Elastomeric bearings; Critical load; Shear strain; Buckling; ISOLATION BEARINGS; STABILITY;
D O I
10.1016/j.engstruct.2012.02.031
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
One of the most important aspects of the seismic response of elastomeric isolators is their stability under large shear strains. The bearing capacity of elastomeric isolators, indeed, progressively degrades while increasing horizontal displacement. This may greatly influence the design of elastomeric isolators, especially in high seismicity regions, where slender elastomeric isolators subjected to large horizontal displacements are a common practice. In the current design approach the critical load is evaluated based on the Haringx theory, modified to account for large shear strains by approximate correction factors. In this paper the critical behavior of a pair of slender elastomeric devices is experimentally evaluated at different strain amplitudes, ranging from approximately 50% to 150%. The experimental results are then compared to the predictions of a number of semi-empirical and theoretical formulations. The main conclusion of this study is that current design approaches are overly conservative for slender elastomeric seismic isolators, since they underestimate their critical load capacity at moderate-to-large shear strain amplitudes. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:198 / 204
页数:7
相关论文
共 50 条
  • [1] Critical tension-shear load of elastomeric seismic isolators: An experimental perspective
    Shen, Chao-yong
    Tan, Ping
    Cui, Jie
    Ma, Yu-hong
    Huang, Xiang-yun
    ENGINEERING STRUCTURES, 2016, 121 : 42 - 51
  • [2] Elastomeric seismic protection isolators for bridges
    Kobayashi, E.
    Kaneko, K.
    International Polymer Science and Technology, 2012, 39 (08)
  • [3] Fiber reinforced elastomeric isolators for the seismic isolation of bridges
    Al-Anany, Yasser M.
    Tait, Michael J.
    COMPOSITE STRUCTURES, 2017, 160 : 300 - 311
  • [4] Elastomeric seismic-protection isolators for buildings and bridges
    Toshio Nishi
    Nobuo Murota
    Chinese Journal of Polymer Science, 2013, 31 : 50 - 57
  • [5] Elastomeric seismic-protection isolators for buildings and bridges
    Nishi, Toshio
    Murota, Nobuo
    CHINESE JOURNAL OF POLYMER SCIENCE, 2013, 31 (01) : 50 - 57
  • [6] Effects of air temperature on the cyclic behavior of elastomeric seismic isolators
    Cardone, Donatello
    Gesualdi, Giuseppe
    Nigro, Domenico
    BULLETIN OF EARTHQUAKE ENGINEERING, 2011, 9 (04) : 1227 - 1255
  • [7] Effects of air temperature on the cyclic behavior of elastomeric seismic isolators
    Donatello Cardone
    Giuseppe Gesualdi
    Domenico Nigro
    Bulletin of Earthquake Engineering, 2011, 9 : 1227 - 1255
  • [8] Current Status of Seismic Isolation and Technology of Elastomeric Isolators in Japan
    Toshio Nishi
    Naruhiko Mashita
    Nobuo Murota
    中国橡胶, 2012, 28 (04) : 10 - 12
  • [9] Experimental performance of unbonded polyester and carbon fiber reinforced elastomeric isolators under bidirectional seismic excitation
    Losanno, Daniele
    Madera Sierra, Ingrid E.
    Spizzuoco, Mariacristina
    Marulanda, Johannio
    Thomson, Peter
    ENGINEERING STRUCTURES, 2020, 209
  • [10] Performance of elastomeric seismic isolators under long-period earthquakes
    Abrar, O.
    Tuhta, S.
    MAGAZINE OF CIVIL ENGINEERING, 2022, 110 (02):