Integral energy performance characterization of semi-transparent photovoltaic elements for building integration under real operation conditions

被引:73
|
作者
Olivieri, L. [1 ]
Caamano-Martin, E. [1 ]
Olivieri, F. [2 ]
Neila, J. [2 ]
机构
[1] Univ Politecn Madrid, Inst Energia Solar, E-28040 Madrid, Spain
[2] Univ Politecn Madrid, Escuela Tecn Super Arquitectura, Dept Construct & Technol Architecture, E-28040 Madrid, Spain
关键词
Building integrated photovoltaics; BIPV modules; Semi-transparent photovoltaics; Energy efficiency; Experimental study; THERMAL PERFORMANCE; SOLAR-CELLS; PV; FENESTRATION; MODULES; SAVINGS; SYSTEM; FACADE;
D O I
10.1016/j.enbuild.2013.09.035
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In this paper, a methodology for the integral energy performance characterization (thermal, daylighting and electrical behavior) of semi-transparent photovoltaic modules (STPV) under real operation conditions is presented. An outdoor testing facility to analyze simultaneously thermal, luminous and electrical performance of the devices has been designed, constructed and validated. The system, composed of three independent measurement subsystems, has been operated in Madrid with Four prototypes of a-Si STPV modules, each one corresponding to a specific degree of transparency. The extensive experimental campaign, continued for a whole year rotating the modules under test, has validated the reliability of the testing facility under varying environmental conditions. The thermal analyses show that both the solar protection and insulating properties of the laminated prototypes are lower than those achieved by a reference glazing whose characteristics are in accordance with the Spanish Technical Building Code. Daylighting analysis shows that STPV elements have an important lighting energy saving potential that could be exploited through their integration with strategies focused to reduce illuminance values in sunny conditions. Finally, the electrical tests show that the degree of transparency is not the most determining factor that affects the conversion efficiency. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:280 / 291
页数:12
相关论文
共 42 条
  • [41] Semi-transparent BIPV/T System's synergistic operation with air treatment for electricity generation and complementary cold-heat utilization: Assessment of energy and daylight performance
    Tang, Yayun
    Zhang, Chengyan
    Ji, Jie
    Xie, Hao
    APPLIED ENERGY, 2025, 383
  • [42] Energy analysis of ventilated building-integrated semi-flexible crystalline silicon photovoltaic system under warm weather conditions
    Luo, Chenglong
    Su, Xiaoxiao
    Ma, Shixian
    Chen, Xinzhu
    Ji, Jie
    Yu, Yanshun
    Zhang, Hua
    Peng, Ruili
    RENEWABLE ENERGY, 2025, 239