Accuracy of three digital scanning methods for complete-arch tooth preparation: An in vitro comparison

被引:22
|
作者
Gao, Hanqi [1 ,2 ,3 ,4 ]
Liu, Xiaoqiang [1 ,2 ,3 ,4 ]
Liu, Mingyue [5 ]
Yang, Xu [6 ]
Tan, Jianguo [1 ,2 ,3 ,4 ,7 ]
机构
[1] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, Beijing, Peoples R China
[2] Natl Clin Res Ctr Oral Dis, Beijing, Peoples R China
[3] Natl Engn Lab Digital & Mat Technol Stomatol, Beijing, Peoples R China
[4] Beijing Key Lab Digital Stomatol, Beijing, Peoples R China
[5] Peking Univ, Sch & Hosp Stomatol, Clin Div 1, Beijing, Peoples R China
[6] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, Beijing, Peoples R China
[7] Peking Univ, Sch & Hosp Stomatol, Dept Prosthodont, 22 Zhongguancun Ave South, Beijing 100081, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2022年 / 128卷 / 05期
基金
中国国家自然科学基金;
关键词
IMPRESSION TECHNIQUE; INTRAORAL SCANNERS; SYSTEMS; STRATEGIES; PRECISION; IMPACT; SCANS;
D O I
10.1016/j.prosdent.2021.01.029
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. The accuracy of digital scanning for complete dental arch and implant-supported complete-arch restorations has been reported. However, research addressing the accuracy of digital scanning methods for complete-arch tooth preparation is lacking. Purpose. The purpose of this in vitro study was to compare the accuracy of intraoral scanning, impression scanning, and cast scanning for complete-arch preparation.Material and methods. Maxillary and mandibular jaw typodonts with 28 teeth prepared for complete crowns were used as reference casts and digitized as reference data sets with a desktop scanner. Three digital scanning methods were applied. First, the reference casts were each scanned 10 times with an intraoral scanner to generate the intraoral scanning group data sets. Second, the reference casts were each captured 10 times by using polyvinyl siloxane impression material, and the impressions were scanned with a desktop scanner to generate the impression scanning group data sets. Third, the impressions obtained in the impression scanning group were used to make gypsum casts which were then digitized with a desktop scanner to generate the cast scanning group data sets. Accuracy was determined by trueness and precision. Three-dimensional deviations of the prepared arches and anterior and posterior segments were measured from root mean square values and depicted on color-difference maps. Differences among test groups were analyzed by using a 1-way ANOVA and the post hoc Bonferroni test for normally distributed data or the Kruskal-Wallis test with Bonferroni correction for non-normally distributed data (a=.05).Results. The trueness of the maxillary arch was significantly higher in the impression scanning group than in the cast scanning and intraoral scanning groups (P<.05), but no significant differences were found among the 3 groups of the mandibular arch (P>.05). The precision of both arches was significantly higher in the impression scanning and intraoral scanning groups than in the cast scanning group (P<.05). Color maps showed horizontal symmetrical displacement in the intraoral scanning group relative to the reference data sets and within-group unilateral distal-end distortion. Irregular arch deformations were noted in the impression scanning group, and buccal and occlusal expansion occurred in the anterior-posterior direction in the cast scanning group. Pooled data for anterior teeth indicated that the trueness was lowest in the intraoral scanning group; however, that for the maxillary anterior teeth did not differ, while that for the mandibular anterior teeth differed significantly among groups (P<.05). For the posterior teeth, deviation was the lowest in the impression scanning group, and significant differences were noted in both arches among the 3 groups (P<.05).Conclusions. Of the methods tested, impression scanning was the most accurate for the creation of a digital cast of a complete prepared arch. (J Prosthet Dent 2022;128:1001-8)
引用
收藏
页码:1001 / 1008
页数:8
相关论文
共 50 条
  • [41] Comparison of conventional, photogrammetry, and intraoral scanning accuracy of complete-arch implant impression procedures evaluated with a coordinate measuring machine
    Revilla-Leon, Marta
    Att, Wael
    Ozcan, Mutlu
    Rubenstein, Jeffrey
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 125 (03): : 470 - 478
  • [42] Effect of Scanner Type and Scan Body Location on the Accuracy of Mandibular Complete-Arch Digital Implant Scans: An In Vitro Study
    Cakmak, Gulce
    Yilmaz, Hakan
    Santos, Alejandro Trevino
    Kokat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 419 - 426
  • [43] Accuracy of four digital scanners according to scanning strategy in complete-arch impressions (vol 13, e0202916, 2018)
    Medina-Sotomayor, Priscilla
    Pascual-Moscardo, Agustin
    Camps, Isabel
    PLOS ONE, 2018, 13 (12):
  • [44] Evaluation of the accuracy of seven intraoral scanners for the full dentate and partially edentulous complete-arch mandibular casts: An in vitro comparison
    Wang, Xin
    Zhang, Fang
    Ma, Dan
    Ye, Xiaolan
    Zheng, Xiaojuan
    Ren, Ruifang
    Ren, Nan
    Bai, Shizhu
    HELIYON, 2024, 10 (10)
  • [45] Accuracy of digital complete-arch, multi-implant scans made in the edentulous jaw with gingival movement simulation: An in vitro study
    Knechtle, Nathalie
    Wiedemeier, Daniel
    Mehl, Albert
    Ender, Andreas
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (03): : 468 - 478
  • [46] Accuracy of digital impressions for implant-supported complete-arch prosthesis, using an auxiliary geometry part-An in vitro study
    Iturrate, Mikel
    Eguiraun, Harkaitz
    Solaberrieta, Eneko
    CLINICAL ORAL IMPLANTS RESEARCH, 2019, 30 (12) : 1250 - 1258
  • [47] The effect of scanner type and scan body position on the accuracy of complete-arch digital implant scans
    Cakmak, Gulce
    Yilmaz, Hakan
    Trevino, Alejandro
    Kokat, Ali Murat
    Yilmaz, Burak
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 533 - 541
  • [48] Influence of Implant ScanBody Material and Intraoral Scanners on the Accuracy of Complete-Arch Digital Implant Impressions
    Azevedo, Luis
    Marques, Tiago
    Karasan, Duygu
    Fehmer, Vincent
    Sailer, Irena
    Correia, Andre
    Polo, Miguel Gomez
    INTERNATIONAL JOURNAL OF PROSTHODONTICS, 2024, 37 (05)
  • [49] Effect of Scan Pattern on the Accuracy of Complete-Arch Digital Implant Impressions with Two Intraoral Scanners
    Li, Zhipeng
    Huang, Ruoxuan
    Wu, Xiayi
    Chen, Zetao
    Huang, Baoxin
    Chen, Zhuofan
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 731 - 739
  • [50] ACCURACY OF IMPRESSION MATERIALS FOR COMPLETE-ARCH FIXED PARTIAL DENTURES
    LIN, CC
    ZIEBERT, GJ
    DONEGAN, SJ
    DHURU, VB
    JOURNAL OF PROSTHETIC DENTISTRY, 1988, 59 (03): : 288 - 291