Low Dead Volume Integrated Separation Columns and Fabry-Perot Sensors for Micro-Gas Chromatography

被引:0
|
作者
Reddy, Karthik [1 ,2 ]
Liu, Jing [1 ]
Oo, Maung Kyaw Khaing [1 ]
Fan, Xudong [1 ]
机构
[1] Univ Michigan, Dept Biomed Engn, 1101 Beal Ave, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Elect Engn & Comp Sci, Ann Arbor, MI 48109 USA
基金
美国国家科学基金会;
关键词
Micro-gas chromatography; vapor sensing; Fabry-Perot cavity; volatile organic compounds;
D O I
10.1117/12.2003100
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We developed a monolithic subsystem that integrates a micro-gas chromatography (mu GC) separation column and on-column, non-destructive Fabry-Perot (FP) vapor sensors on a single silicon chip. The device was fabricated using deep reactive ion etching of silicon to create fluidic channels and polymers were deposited on the same silicon chip to act as a stationary phase or an FP sensor, thus avoiding dead volumes caused by the interconnects between the column and sensor traditionally used in mu GC. Two integration designs were studied. In the first design, the mu GC column was coated with a layer of polymer that served as both the stationary phase and the FP sensor, which has the greatest level of integration. In the second design, a FP sensor array spray-coated with different vapor sensing polymers was integrated with the mu GC column, which significantly improves the system flexibility and detection sensitivity. With this design, we show that the FP sensors have a detection limit on the order of tens of picograms with a sub-second response time. Furthermore, FP sensor array are shown to respond to a mixture of analytes separated by the integrated separation channel, allowing for the construction of response patterns, which, along with retention time, can be used as a basis of analyte identification.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Fiber-integrated refractive index sensor based on a diced Fabry-Perot micro-resonator
    Suntsov, Sergiy
    Ruter, Christian E.
    Schipkowski, Tom
    Kip, Detlef
    APPLIED OPTICS, 2017, 56 (33) : 9139 - 9143
  • [32] Micromachined Tunable Fabry-Perot Filter Integrated into a Miniaturized Spectrometer for Low-Cost Applications
    Woidt, Carsten
    Setyawati, O.
    Albrecht, A.
    Engenhorst, M.
    Daneker, V.
    Woit, T.
    Wittzack, S.
    Koehler, F.
    Mai, H. H.
    Bartels, M.
    Hillmer, H.
    NANOTECHNOLOGICAL BASIS FOR ADVANCED SENSORS, 2010, : 537 - +
  • [33] High-finesse micro-lens fiber-optic extrinsic Fabry-Perot interferometric sensors
    Jiang, Yi
    Tang, Caijie
    SMART MATERIALS AND STRUCTURES, 2008, 17 (05)
  • [34] Miniature on-fiber extrinsic Fabry-Perot interferometric vibration sensors based on micro-cantilever beam
    Ma, Weiyi
    Jiang, Yi
    Zhang, Han
    Zhang, Liuchao
    Hu, Jie
    Jiang, Lan
    NANOTECHNOLOGY REVIEWS, 2019, 8 (01) : 293 - 298
  • [35] A broad band signal processing technique for miniature low-finesse Fabry-Perot interferometric sensors
    Potter, J
    Ezbiri, A
    Tatam, RP
    OPTICS COMMUNICATIONS, 1997, 140 (1-3) : 11 - 14
  • [36] A Five-Hole Pressure Probe Based on Integrated MEMS Fiber-Optic Fabry-Perot Sensors
    Song, Yumiao
    Ma, Shuanghui
    Zhao, Jichun
    Liu, Jia
    Wang, Jingyi
    Cui, Yongjun
    MICROMACHINES, 2024, 15 (04)
  • [37] Demonstration of motionless Knudsen pump based micro-gas chromatography featuring micro-fabricated columns and on-column detectors
    Liu, Jing
    Gupta, Naveen K.
    Wise, Kensall D.
    Gianchandani, Yogesh B.
    Fan, Xudong
    LAB ON A CHIP, 2011, 11 (20) : 3487 - 3492
  • [38] Micro-ring resonator quality factor and extinction ratio enhancement via integrated Fabry-Perot cavity
    Wu, Jiayang
    Moein, Tania
    Xu, Xingyuan
    Moss, David J.
    Ren, Guanghui
    Mitchell, Arnan
    2017 CONFERENCE ON LASERS AND ELECTRO-OPTICS PACIFIC RIM (CLEO-PR), 2017,
  • [39] Antiresonant mechanism based self-temperature-calibrated fiber optic Fabry-Perot gas pressure sensors
    Gao, Hongchun
    Jiang, Yi
    Zhang, Liuchao
    Cui, Yang
    Jiang, Yuan
    Jia, Jingshan
    Jiang, Lan
    OPTICS EXPRESS, 2019, 27 (16) : 22181 - 22189
  • [40] NOVEL DUAL-BAND FABRY-PEROT CAVITY ANTENNA WITH LOW-FREQUENCY SEPARATION RATIO
    Kim, Dongho
    MICROWAVE AND OPTICAL TECHNOLOGY LETTERS, 2009, 51 (08) : 1869 - 1872