A simple and efficient method for evaluating air-cleaning performance against airborne allergen particles

被引:7
|
作者
Kim, Hak-Joon [1 ]
Han, Bangwoo [1 ]
Kim, Yong-Jin [1 ]
Jeong, Choon-Soo [2 ]
Lee, Sung-Hwa [3 ]
机构
[1] Korea Inst Machinery & Mat, Environm & Energy Syst Res Div, Taejon 305343, South Korea
[2] Univ Ulsan, Sch Biol Sci, Ulsan 389749, South Korea
[3] LG Elect, Digital Appliance Co Res Lab, Seoul 153802, South Korea
关键词
Allergen; Airborne particles; ELISA; Optical particle counter; Clean-air delivery rate; Removal efficiency; INDOOR ALLERGENS; CAT ALLERGEN; EXPOSURE; DUST; REMOVAL; FILTRATION; CLEANERS; ASTHMA; HOMES;
D O I
10.1016/j.buildenv.2012.11.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Size- and time-dependent aerodynamic behaviors of airborne allergen particles were evaluated in a 30-m(3) chamber, both with and without the operation of air-cleaning devices: a dehumidifier and an air conditioner. In-situ real-time measurements were taken using an optical particle counter. Removal efficiencies obtained from the counter, based on particle number and volumetric concentrations, were compared to values from the conventional ELISA method, which is time-consuming and requires off-line measurements. The log of clean-air delivery rates (CADR) was linearly proportional to the log of particle size. When a dehumidifier and an air conditioner were used, CADRs against airborne allergen particles increased by 4 and 7 times, respectively, compared with conditions without air-cleaning devices. The settlement of the particles smaller than 1 gm was hardly affected by gravity, but concentrations of these particles decreased to nearly 50 and 30% of the initial concentrations with the operation of a dehumidifier and of an air conditioner, respectively. Moreover, the concentration of particles with a peak size of about 5.7-mu m decreased to 9 and 0.3% of the initial value after only 30 min of operation of a dehumidifier and of an air conditioner, respectively. Comparing removal performance results between analyses that used a particle counter and the ELISA method, our new simple test method, which used an optical counter and was based on total volume concentrations, could easily predict the removal efficiency of airborne allergen particles, and the results were consistent with those obtained using the ELISA method. (c) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:272 / 279
页数:8
相关论文
共 50 条
  • [21] A Simple Method for Evaluating the Sustainable Design of Energy Efficient Family Houses
    Praznik, Miha
    Butala, Vincenc
    Zbasnik-Senegacnik, Martina
    STROJNISKI VESTNIK-JOURNAL OF MECHANICAL ENGINEERING, 2014, 60 (06): : 425 - 436
  • [22] A simple and rapid method for evaluating the disintegration performance of compound fertilizer
    He, Yunyi
    Huang, Chunni
    Zhai, Hongbin
    He, Jian
    Wu, Pan
    Liu, Changjun
    Jiang, Wei
    ARCHIVES OF AGRONOMY AND SOIL SCIENCE, 2024, 70 (01) : 1 - 12
  • [23] SIMPLE METHOD FOR EVALUATING PERFORMANCE OF A COLLIMATOR-CAMERA SYSTEM
    TOWSON, J
    SCOTT, BW
    CORMACK, J
    YEATES, M
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1973, 3 (05): : 523 - 523
  • [24] Polymersomes as virus-surrogate particles for evaluating the performance of air filter materials
    Wang, Shuo
    Liu, Yuan
    Xu, Mengmeng
    Hu, Fei
    Yu, Qianqian
    Wang, Linge
    GIANT, 2022, 10
  • [25] Methods for Measuring Performance of Vehicle Cab Air Cleaning Systems Against Aerosols and Vapours
    Bemer, D.
    Subra, I.
    Regnier, R.
    ANNALS OF OCCUPATIONAL HYGIENE, 2009, 53 (04): : 441 - 447
  • [26] Evaluating test method of air cleaning devices for ozone removal (ASHRAE RP-1579)
    TANG, M. E. N. G. J. I. A.
    OWEN, K. A. T. H. L. E. E. N.
    NOVOSELAC, A. T. I. L. A.
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2022, 28 (07) : 886 - 895
  • [27] Multivariate optimization of a simple and sensitive method for the determination of secondary biogenic organic compounds in airborne particles
    Mologousi, Athanasia I.
    Bakeas, Evangelos B.
    ANALYTICAL METHODS, 2016, 8 (20) : 4047 - 4055
  • [28] Assessing the performance of air cleaning devices - A full-scale test method
    Bastani, Arash
    Lee, Chang-Seo
    Haghighat, Fariborz
    Flaherty, Chris
    Lakdawala, Ness
    BUILDING AND ENVIRONMENT, 2010, 45 (01) : 143 - 149
  • [29] Salvinia natans microplate assay: A simple and efficient method for evaluating aquatic toxicity
    Cui, Rongxue
    Kwak, Jin Il
    An, Youn-Joo
    MARINE POLLUTION BULLETIN, 2022, 185
  • [30] A simple and effective method of evaluating atomic force microscopy tip performance
    Nie, HY
    McIntyre, NS
    LANGMUIR, 2001, 17 (02) : 432 - 436